Installation and Operation
Instruction Manual
CEW121AS - 12,000
CEW151AS - 15,000
CEW183AS - 18,000
CEW243AS - 24,000
Страница 1: ...Installation and Operation Instruction Manual CEW121AS 12 000 CEW151AS 15 000 CEW183AS 18 000 CEW243AS 24 000 ...
Страница 2: ...nt from those described in this Manual but it does not affect proper operation and usage Please carefully read the sections corresponding to your specific model Keep this Manual for future reference Caution This appliance is not intended for use by young children or infirm persons without supervision young children should be supervised to ensure that they do not play with appliance Contents Instru...
Страница 3: ... not try to stop the operation of the air conditioner by pulling the power cable from the socket II might result in electric shock fire hazard or other accidents Do not operate your air conditioner with wet hands It might lead to electric shock or other hazards If there is dust on the plug or the plugging is not properly done it might lead to electric shock fire hazards or other accidents Improper...
Страница 4: ...nsertsticksorotherhard Do not wash the air objects into the air inlet oroutlet conditioner with water The high speed rotation of the fan blades may cause accidents Do not let the delivered air blow to your body directly for long periods It m i g h t c a u s e discomfort or harm your health It may cause electric shock or other accidents If the air conditioner is not to be used for a long period of ...
Страница 5: ...ls are not supplied with this Power cord Front grille Up down air direction flap Air inlet Left right air direction control tab Features and appearance may vary all the figures provide a demonstration to introduce the function The following are two types of operation panels Please refer to the instructions for the operation panel of your air conditioner OPERATION PANEL 1 9 3 HIGH l FAN MED COOL LO...
Страница 6: ...with A OrT button to set the timer time SPEED button Press this button to set desired fan speed HIGH MED LOW MODE button Press this button to advance the operation mode as follows ENERGY SAVER DRY FAN heating for cooling and heating model COOL Z TEMP TIME button Press this button to adjust set temperature within a range of 16 C 61 F to 32 C 90 F ln timer time setting state press timer button to en...
Страница 7: ... light willbeon M FAN button Presslhisbuttontomakethefans run in middle speed The MED indicationHghtwillbeon L FAN button Pressthisbuttontomakethefans run in low speed The LOW 1 indication lightwillbeon FILTER RESET button r p FI L TERRESET butk ri and CHECKFn TER LEDllgntswlllgo TIMER button Press thisbutton to set the time for timed switch on switch off or to delete the timing TIMER Signal trans...
Страница 8: ...t give an acknowledgment sound It means the batteries may be exhausted and need replacing 1 Remove the battery case cover and take the used batteries out by sliding the cover open in the arrow direction 2 Replace with new batteries and pay attention to the and marks of pole indications 3 Reinstall the battery cover ADJUSTMENT OF AIR DIRECTION Up down adjustment Hold the up down air flap by hand an...
Страница 9: ...he air filter screen at a standard interval of once every two weeks Remove the air filter screen 1 Gently hold and press the two lower ends of the front grille and open the grille 2 Gently grab the air filter screen and lift it up and then take ii out in the direction toward you Clean the air filter screen If the air filter screen is very dirty you may use lukewarm water about 30 C 86 F to clean i...
Страница 10: ...g There is no sufficient cooling or heating Is the room temperature set properly suita l e TEMP T Is the room directly exposed to sunlight Is the air filterclean not blocked Are doors or windows opened Are there any heating sources inside the room e 1 p r J Are there many people inside the room Note If the air conditioner remains abnormal in operation after the above checks and inspection please d...
Страница 11: ... This is to protect the air conditioner When the machine is powered for the first time compressor starts immediately When the indoor temperature and humidity is high such phenomena might occur When the indoor temperature and humidity drops the fog will disappear It might be the smell of cigarette smoke or other things inside the air conditioner This is caused by the flow of the refrigerant inside ...
Страница 12: ...driver available for installation ITEM NAME OF PARTS Q TY A SHORT SCREWS 10 B WOOD SCREWS 13 C UPPER GUIDE 1 D SEAL BOTTOM TO UNIT 1 E CURTAIN 2 F CURTAIN LOCK 2 G SASH LOCK 1 H WINDOW SASH SEAL 1 I SCREW AND LOCKNUT 4 J FLAT HEAD BOLT AND 2 LOCKNUT K SILL ANGLE BRACKET 2 L WINDOWSUPPORT BRACKET 2 Note The number of short screws varies by model INSTALLATION POSITION Pick a location which will allo...
Страница 13: ...et on floor a bench or a table Remove the upper guide and curtain from the carton place them on a flat surface Align the hole in the upper guide with those in the top of the unit Secure the upper guide to the unit with short screws as shown in FIG 8 Note Higher side of upper guide to be facing the room side Insert top and bottom legs of window filler panel frame into channel to the angle and botto...
Страница 14: ...s You may wish to pre drill pilot holes Add bottom rail seal over screws to window still See FIG 11 CJ INSTALL support bracket Hold each support bracket flush against outside of sill and tight ofbottom of cabinet as shown below Mark brackets at top level of sill and remove see FIG 12 Assemble sill angle bracket to support brackets at the marked position as shown Hand tighten but allow for any chan...
Страница 15: ...is the reverse of removal outlined in section 1 fj SECURE THE AIR CONDITIONER Extend the curtain panels to fill the window opening Place the curtain lock between the curtain extensions and the window sill drive locking screws through the lock and into the sill Secure the left and right flanges on end bottom side of the panel with wood screws Drive locking screws through upper frame holes into wind...
Страница 16: ...n lock and remove screws installed through curtain Close curtain panels into frame FIG 18 Keeping a firm grip on the air conditioner raise the sash and carefully tilt the air conditioner backward draining any condensate water in the base of unit Be careful not to spill any remaining water while lifting unit from window Store parts with air conditioner CAUTION FOR DISMANTLING THE AIR CONDITIONER fo...
Страница 17: ...12 24K CEW121 151 183 243AS Installation and Operation Instruction Manual 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 18: ...12 24K CEW121 151 183 243AS Installation and Operation Instruction Manual 17 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 19: ...om the factory REMEDY PROVIDED BY THE LIMITED EXPRESS WARRANTY The sole remedy under the Limited Warranty is replacement of the defective unit If replacement parts are required within the period of this warranty Coast Air replacement parts shall be used any warranty on the replacement part s shall not affect the applicable original unit warranty Labor to diagnose and replace the defective unit is ...
Страница 20: ...5 2017 ...