Installation and Operation
Instruction Manual
Portable Room Air Conditioner
CEP-81B
CEP-101B
CEP-121B
www.coastair-ac.com
Страница 1: ...Installation and Operation Instruction Manual Portable Room Air Conditioner CEP 81B CEP 101B CEP 121B www coastair ac com ...
Страница 2: ...ration Instructions Other features Safety Precautions Air Filter Cleaning Troubleshooting Tips Unit Cleaning Store the unit when not in use Preparation Design Notice Ambient Temperature Range For Unit Operating Exhaust Hose Installation Choosing The Right Location Tools Needed Accessories Window Installation Kit Installation Troubleshooting Tips 03 11 11 Energy Rating Information 12 11 12 12 13 13...
Страница 3: ...he unit The maximum current is indicated on the nameplate located on unit have a qualified electrician install the proper receptacle Install the unit on a flat sturdy surface Failure to do so could result in damage or excessive noise and vibration The unit must be kept free from obstruction to ensure proper function and to mitigate safety hazards Do not modify the length of the power cord or use a...
Страница 4: ...ervised to ensure that they do not play with the appliance Children must be supervised around the unit at all times be applicable for other countries except the European Countries If the supply power cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Prior to cleaning or other maintenance the appliance must be disconn...
Страница 5: ... stable level surface during use Always contact a qualified person to carry out repairs If the damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and not repaired Hold the plug by the head of the power plug when taking it out Turn off the product when not in use WARNING for Using R32 R290 Refrigerant Do not use means to accelerate the def...
Страница 6: ...tenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants Please follow the instructions carefully to handle install clear andservice the air conditioner to avoid any damage or hazard Flammable Refrigerant R32 is used within the air conditioner When maintaining or disposing of the a...
Страница 7: ...e complied with prior to conducting work on the system 2 Work procedure Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapor being present while the work is being performed 3 General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out Work in confined spaces shall be...
Страница 8: ...igerant and preferably expel it externally into the atmosphere 8 Checks to the refrigeration equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the manufacturer s maintenance and service guidelines shall be followed If in doubt consult the manufacturer s technical department for assistance The following checks sha...
Страница 9: ... may react with the refrigerant and corrode the copper pipe work If a leak is suspected all naked flames shall be removed extinguished If a leakage of refrigerant is found which requires brazing all of the refrigerant shall be recovered from the system or isolated by means of shut off valves in a part of the system remote from the leak Oxygen free nitrogen OFN shall then be purged through the syst...
Страница 10: ...nd all its detail It is recommended good practice that all refrigerants are recovered safely Prior to the task being carried out an oil and refrigerant sample shall be taken in case analysis is required prior to re use of reclaimed refrigerant It is essential that electrical power is available before the task is commenced 15 Become familiar with the equipment and its operation b Isolate system ele...
Страница 11: ...be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants In addition a set of calibrated weighing scales shall be available and in good working order Hoses shall be complete with leak free disconnect couplings and in good condition Before using the recovery machine check that it is in satisfactory ...
Страница 12: ...e damage to the unit 50cm 19 7 inch How to Stay Cool with a New Portable Air Conditioner For the models comply with the requirements of Department Of Energy in US Because of a new federal test procedure for Portable Air Conditioners you may notice that the cooling capacity claims on portable air conditioner packaging are significantly lower than that of models produced prior to 2017 This is due to...
Страница 13: ...find the proper air conditioner determine the square footage of the room you want to cool by multiplying the room length by its width You also need to know the air conditioner s BTU British Thermal Unit rating which indicates the amount of heat it can remove from a room A higher number means more cooling power for a larger room Be sure you are comparing only newer models to each other older models...
Страница 14: ...M E R O F F M O D E FA N S LE E P S W IN G LE D 1 set 1 pc Window Slider B Remote Controller and Battery only for remote control models 2 pc Foam Seal A Adhesive 2 pc Foam Seal B Adhesive 4 set Screw and anchor only for wall installation models 1 pc Foam Seal C Non adhesive 1 pc Drain Hose Adaptor only for heat pump mode 1 pc 2 pc Window Installation Kit Press the exhaust hose into the window slid...
Страница 15: ...wer groove of the air outlet of the unit while the hook of the adaptor is aligned with the hole seat of the air outlet and slide down the Exhaust hose assembly along the arrow direction for installation Step Three Preparing the Adjustable Window Slider Window slider A Window slider B Bolt 1 Choose the window sliders according to the size of your window Sometimes it needs to be cut short to meet th...
Страница 16: ...esive foam seal A and B strips to the proper lengths and attach them to the window sash and frame as shown 3 Cut the non adhesive foam seal C strip to match the width or height of the window Insert the seal between the glass and the window frame to prevent air and insects from getting into the room 2 Insert the window slider assembly into the window opening Or Foam seal B Adhesive type shorter Foa...
Страница 17: ...no obstacle of 20 in in order to the exhaust system works properly All the illustrations in this manual are for explanation purpose only Your air conditioner may be slightly different The actual shape shall prevail Installation Instructions Or Or 2 Screws Security Bracket 4 If desired install the security bracket with 2 screws as shown 5 Insert the window slider adaptor into the hole of the window...
Страница 18: ...tant fan light will go out identifying the fan cycle run with compressor stop On some models the Ion light is used instead of constant fan light Press the button for 3 seconds the Ionizer is energized and will help to remove pollen and impurities from the air Wireless button On some models Used to initiate the wireless connection mode For the first time to use wireless function press the wireless ...
Страница 19: ...ur desired room temperature The temperature can be set within a range of 62 F 88 F or 86 F Press the FAN SPEED button to choose the fan speed Note For some models the fan speed can not be adjusted under HEAT mode DRY operation Press the MODE button until the DRY indicator light comes on Under this mode you cannot select a fan speed or adjust the temperature The fan motor operates at LOW speed Keep...
Страница 20: ...SING feature On some models NOTE This feature can be activated from the remote control ONLY The remote control serves as a remote thermostat allowing for the precise temperature control at its location To activate the Follow Me Temp Sensing feature point the remote control towards the unit and press the Follow Me Temp Sensing button The remote control will send this signal to the air conditioner u...
Страница 21: ...cure so there are no leaks Direct the hose toward the drain making sure that there are no kinks that will stop the warter flowing Place the end of the hose into the drain and make sure the end of the hose is down to let the water flow smoothly See Figs with Don t ever let it up See Figs with When the continuous drain hose is not used ensure that the corresponding drain plug and knob are installed ...
Страница 22: ...following section Run the appliance on FAN mode for 12 hours in a warm room to dry it and prevent mold Turn off the appliance and unplug it Clean the air filter according to the instructions in the previous section Reinstall the clean dry filter before storing Remove the batteries from the remote control Maintenance Upper filter take out lower filter B take out lower filter A Press the grill down ...
Страница 23: ... unit disconnect the hose check for blockage and reconnect the hose Remove the heat sources if possible The unit is noisy and vibrates too much The unit makes a gurgling sound The ground is not level Place the unit on a flat level surface The air filter is blocked with dust or animal hair Turn off the unit and clean the filter according to instructions This sound is caused by the flow of refrigera...
Страница 24: ...ty begins on the date of shipment from the factory REMEDY PROVIDED BY THE LIMITED EXPRESS WARRANTY The sole remedy under the Limited Warranty is replacement of the defective unit Labor to diagnose and replace the defective unit is not covered by this Limited Express Warranty If for any reason the replacement product is no longer available during the warranty period Coast Air shall have the right t...
Страница 25: ...www coastair ac com 6 2020 ...