USER’S MANUAL
VER. 1
M26
– 12R EXPANSION BOARD
Rev. 5
APRIL 2021
Страница 1: ...USER S MANUAL VER 1 M26 12R EXPANSION BOARD Rev 5 APRIL 2021 ...
Страница 2: ...F CONTENTS Contents Page 1 0 OVERVIEW 1 2 0 FEATURES 1 3 0 SPECIFICATIONS 2 4 0 BOARD DESCRIPTION 2 5 0 POWER TERMINAL 3 6 0 ENABLE TERMINAL 3 7 0 INPUT SIGNALS 10 11 12 13 AND 15 4 8 0 WIRING INPUT SIGNALS 4 9 0 PINOUT M26 6 10 0 DIMENSIONS 7 ...
Страница 3: ...anical relays with NO and NC positions Use IDC26 to connect to the ESS M16D PoKeys UC300ETH 5LPT AXBB C25XP C94 or C76 UC300ETH Status LEDs on all relay connections External Enable Pin EN The board has a pin that allows you to enable disable all the relays at once Can be powered and tied to the ENABLE line of the C72 M16D C25XP Rev4 and C94 through IDC26 ribbon cable NEW Has terminals to allow acc...
Страница 4: ...IFICATIONS ELECTROMECHANICAL RELAYS SPECIFICATIONS Maximum Current AC 7A 240VAC 10A 125VAC Maximum Current DC 15A 24VDC 10A 28VDC 4 0 BOARD DESCRIPTION Requirements It requires a 5VDC 0 5Amp external power supply to operate WARNING ...
Страница 5: ...L The card must be provided with a 5VDC signal to enable operation This feature has been added to enable you to control externally the status of the relays of the card You can add an external switch to provide the enabling signal If using this board with a C25XP C94 C76 or M16D a jumper can be left in place the board will automatically be tied to the enable line of the main board So when the main ...
Страница 6: ...User s Manual Page 4 7 0 INPUT SIGNALS 10 11 12 13 AND 15 the input pin is activated with 5vdc 8 0 WIRING INPUT SIGNALS ...
Страница 7: ...er s Manual Page 5 Wiring inputs using an external 24VDC power supply to keep input circuit isolated Note If using a 24vdc a 20K resistor is necessary to limit the voltage as the inputs can take only 5vdc ...
Страница 8: ...26 FUNCTION PINHEADER 26 PINS RELAY_1 1 RELAY_2 2 RELAY_3 3 RELAY_4 4 RELAY_5 5 RELAY_6 6 RELAY_7 7 RELAY_8 8 RELAY_9 9 RELAY_10 14 RELAY_11 16 RELAY_12 17 INPUT_10 10 INPUT_11 11 INPUT_12 12 INPUT_13 13 INPUT_15 15 ENABLE 18 GND 19 25 ...
Страница 9: ... machines Neither DUNCAN USA LLC nor Arturo Duncan is liable for any accidents resulting from the improper use of these devices This product is not a fail safe device and it should not be used in life support systems or in other devices where its failure or possible erratic operation could cause property damage bodily injury or loss of life ...