With "
OK
" the machine is ready. "
Emergency
Stop
" means that either one of the emergency stop
buttons on the machine or on the control is pressed, or there is a problem with the electronics
(power failure, interrupted cables, etc.). The exclamation point triangular
warning
sign
indicates a
problem with an external device that is signalled by an alarm signal (see "Frequency converter
alarm" in the status field above). In this case, please refer to the instructions of the external
extension (for example, the frequency converter) for the cause and instructions for correcting the
problem.
The warning sign with the door appears if the machine is equipped with a
safety
door
and it is
open. This is described in more detail below.
When the
DEMO
icon appears, there is (still) no connection to the hardware. The
software runs in demonstration mode and simulates the machine movement only in the
3D graphics. The right-hand plugged icon indicates that a connection existed but was
subsequently disconnected (see below, "Connection interrupted")
Regardless of the state of the machine, there is another reason why functions may be limited: Some
functions require special rights. In order to be able to change the machine parameters, for example,
you have to be logged in as an administrator. Therefore, in the picture below "Configuration -
Machine" is greyed out. (See also "
User-Login
")
C o n n e c t i o n i n t e r r u p t e d
The above icon indicates that the connection to the CncPod has been disconnected. This may not
only be due to the cable connection itself but also to the operating system (anti-virus, firewall,
energy-saving mode, see also chapter "
Installing CncPod
").
If this always happens at a certain time, e.g. Turning on a powerful device (compressor, exhaust)
indicates electromagnetic interference. A momentary voltage fluctuation can lead to a breakdown of
communication between PC and CncPod.
On the other hand, if it is idle, but always after a certain amount of time after starting the software,
the power-saving mode of the PC can be the problem. For Windows 8 and 10, and especially for
portable devices, the operating system may shut down the network connection after a few minutes
without Internet usage. This can be prevented if the CncPod is connected via a network switch.
To re-establish the connection, first check all cable connections and the power supply, and then go
to the menu "
Configuration->Hardware
".