ORINE FEEDER ENGINEERED FOR VARIABLE SPEED PUMPS

CMP# 25280-15X-000, 25280-16X, 25280-17X, 25280-45X, 25280-46X

READ ALL INFORMATION BEFORE PROCEEDING WITH ANY INSTALLATION. THE INFORMATION WILL HELP YOU INSTALL YOUR FEEDER PROPERLY AND AVOID PROBLEMS.

The Powerclean Ultra VS feeder comes with the Powerclean VS Low Flow Inlet, Cone and Outlet pre-installed. These are for systems with 2-speed or variable speed pumps
where the system flow is less than 50 gpm at the lower speed. If the system uses only a single speed pump, or the low speed is over 50 gpm, remove the inserts. 

INSTALLATION GUIDELINES

Make sure all pumps and timer switches are OFF. The feeder is designed for  permanent installation in the return line of the pool or spa and must always be  installed
after the heater, pool cleaner, valves, filter and all other equipment. Feeder should be installed above the water level. 

IMPORTANT

: Heaters and other  equipment may

be damaged by highly chlorinated water.

If the pool/spa is plumbed with 2" PVC pipe make sure the pump, heater and filter all have 2" inlet and outlet fittings. Glue 2" PVC pipe into feeder inlet and outlet.
When using 1.5” PVC pipe, follow instructions above but glue into 1.5" unions

When plumbing a pool/spa combo where the plumbing and equipment is 2" PVC and  the feeder is installed on the pool return line 

after

 the diverter valve with a

portion  of the water going to the spa, install a minimum section of 6" × 1.5" PVC pipe  directly into the inlet side of the feeder using the 1.5" unions. Continue with  2"
PVC pipe on the outlet side of the feeder. This will compensate for the water  being diverted.

When plumbing 90 degree elbows directly into the feeder inlet it may cause  turbulence inside the elbow which prevents water from entering the feeder.  A minimum
of 6" PVC pipe should be installed between the elbow and the inlet  of the feeder.

The arrows on feeder inlet and outlets should point in the direction of the water flow 

returning

 to  the pool/spa.

Use only PVC cement. Follow the directions on the cement label.  Allow time for the PVC cement to completely dry.

This feeder is designed to use only Trichlor-s-triazinetrione OR Bromine tablets- slow dissolving type. UNDER NO CIRCUMSTANCES MIX Trichlor 

or Bromine with Calcium Hydrochlorite, with other forms of concentrated chlorine or with other chemicals. FIRE AND/OR EXPLOSION MAY 

RESULT. NEVER use oilsor grease to lubricate o-ring. Oil in contact with Trichlor OR Bromine may result in FIRE. Lubricate o-ring with approved 

silicone o-ring lubricant only. If you are not the original owner of this feeder, or not sure which chemical was used, be SAFE and flush thoroughly 

with fresh water. CAUTION SHOULD BE USED WHEN REMOVING CAP. DO NOT INHALE FUMES. IF YOUR POOL OR SPA HAS COPPER PLUMBING 

DO NOT INSTALL. This will damage the feeder. NOTE: If heaters are used, a Fireman’s Switch  or equivalent must be installed to prevent possible 

damage and improper  operation of check valve and other equipment subject to heat damage.

WARNING

OPERATING INSTRUCTIONS
Fill the feeder with water making sure to bleed out any entrapped air in any of  the lines. To ensure maximum 
effectiveness, before starting the feeder the pool  should be properly conditioned and the residual should be 1.0 
to 1.5 ppm.  Consult your local dealer for water conditioning information in your area.
1.

Remove cap of feeder and fill with proper size tablets. For pools use 1" or 3"  diameter tablets. For spas use
1" tablets.

2.

If more chemical and a faster dissolve rate is desired, install the included chemical feeder tube at this time.
The elbow of the feeder tube will fit into  the outlet hole near the inside bottom of unit. If less  chemical is
desired, remove the chemical feeder tube.

3.

Completely fill the chlorinator with water. Replace cap making sure o-ring is clean, lubricated and in place.

4.

Turn on pump and timer switches for a minimum of 6 to 8 hours. The water  level inside chlorinator will be
3 – 5 inches under normal running conditions.

5.

Adjust the control valve clockwise for more chemical or counter clockwise for  less chemical according to
the size of the pool/spa. Use a test kit to determine  the chemical residual. Check the chemical residual be
checked  daily for the first five days. 

NOTE

: Hot weather, high water temperature and  increased use will

cause the pool/spa to use more chemical. Increase the feed  rate a few days in advance when possible. The
valve settings may require adjustment depending on the conditions.

RECHARGING THE FEEDER
1.

Turn control valve to the closed position (counter clockwise).  SHUT OFF PUMP.

2.

Wait one minute allowing the water and fumes to drain from the feeder.

3.

Leave the control valve closed and turn on the pump. (The check valve will  prevent water from entering the
feeder).

4.

Remove cap and fill with tablets.

5.

Replace cap making sure o-ring is clean, lubricated, and in place. (Hand tighten only).

6.

Open control valve (clockwise) to original setting.

WINTERIZING THE FEEDER
This chlorinator has a drain plug located on the 
bottom for easy draining of the  unit for winter. Follow 
other normal procedures for your system to winterize.

SPECIAL INSTRUCTIONS:
1.

If the feeder does not provide enough chemical
residual when using 3” tablets,  switch to 1” tablets
for faster erosion and increased residual.

2.

If the glass lid becomes cloudy, turn off the
feeder using the shut off  instructions above
(RECHARGING FEEDER). Remove the lid and wipe
clean.  If it remains cloudy, it will clear itself if left
exposed to sunlight and fresh air.  

DO NOT

 leave

chlorinator open without the lid installed. If the lid
must be  left off to clear up, a replacement must
be installed temporarily

3.

The bottom grate (#1 in diagram on page 2) is
designed to be removed easily when  chlorine
is gummed up inside the unit.  The chlorine
residue must be dislodged or it may effect feeder
performance. The grate helps keep pieces of the
tablets from clogging the  outlet. Be sure to check
its position after each recharging as the grate
may come out of its resting place when tablets
are added to  the chlorinator.