background image

®

NOVA POOL DRAIN WITH SUMP

25513-26X, 25513-4XX, 25513-5XX, 25513-6XX, 25515-5XX, 25516-26X

25516-4XX, 25516-5XX, 25517-5XX, 25548-5XX

IAPMO Listed VGBA Suction: Compliant to ANSI/APSP - 16 2017 & CPSC 

Requirements

All Custom Molded Products main drains are listed and tested in strict accordance 

to the requirements of ANSI/APSP - 16 2017, the current standard of reference for 

the Virginia Graeme Baker Act, and compliant to the latest Consumer Product 

Safety Commission (CPSC) requirements.

For Multiple Drain Use Only | Submerged | Cover Life: 7 Years | Floor or Wall

VGBA TESTED &

 

CERTIFIED 

ANSI-APSP 16 | CPSC

Содержание NOVA 25513-26 Series

Страница 1: ...uirements All Custom Molded Products main drains are listed and tested in strict accordance to the requirements of ANSI APSP 16 2017 the current standard of reference for the Virginia Graeme Baker Act...

Страница 2: ...3 B Sizing Specification Reference 4 C Installation Maintenance Procedures 6 1 Required for Installation 6 2 Installation Location 6 3 Installation Procedure 6 4 Maintenance Inspection 8 5 Winterizin...

Страница 3: ...MUST have a flow rating capable of the full flow of the pump s for the specific suction system Increasing size of the pump may increase flow rate of suction beyond rated safety limits causing entrapm...

Страница 4: ...mbining the flow rating of all SOFAs minus the flow rating of one If the flow ratings of all SOFAs are not equal subtract the flow rating of the SOFA with the highest flow rating NOTICE No modificatio...

Страница 5: ...0 100 120 140 160 180 200 0 079 3 22 0 72 0 20 1 97 TOTAL HEAD LOSS Feet of Head FLOW RATE 2 5in PIPE 0 0 2 0 2 0 4 0 6 0 8 1 1 4 1 2 0 50 100 150 200 250 03 1 45 0 38 0 18 0 88 TOTAL HEAD LOSS Feet o...

Страница 6: ...tall in the center of the pool spa OR the deepest point b Cover grates when installed shall not protrude more than 2 in 51 mm from the finished surface of the pool in which the SOFA is installed c See...

Страница 7: ...eners The use of adhesives or other attachment methods that prevent access to suction piping or SOFA components requiring periodic servicing is prohibited Hand check cover grate for snugness to the su...

Страница 8: ...replacement is made e If there are stripped screw holes or if the brass insert receptacles are missing removed the SOFA must be replaced Do not use the pool spa facility until a repair or replacement...

Страница 9: ...RAMS AND MEASUREMENTS IMAGE 2 DIMENSIONS NOVA SIDE VIEW LARGE OUTLET NOVA SIDE VIEW A LARGE OUTLET NOVA SIDE VIEW B NOVA BOTTOM VIEW 3 6 8 8 5 8 5 3 75 4 2 6 6 3 8 1 4 7 5 4 9 10 1 8 7 8 5 8 0 3 3 0 9...

Страница 10: ...5515 1 61050 048 025 SCREWS FOR 25517 2 25539 700 011 COVER 3 25513 250 020 PLUG FOR 25513 26X 25516 26X 3 25513 300 020 PLUG FOR 25513 4XX 25516 4XX 3 25520 050 010 PLUG FOR 25513 5XX 25516 5XX 4 255...

Страница 11: ...___________________________________________ Installation Date _____________________________ Model Number ______________________________ Pool Size in Gallons __________________________ CMP Customer Ser...

Страница 12: ...CUSTOM MOLDED PRODUCTS 36 HERRING ROAD NEWNAN GA 30265 WWW C M P COM 0521sb...

Отзывы: