![CMOSTEK CMT2250A Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/cmostek/cmt2250a/cmt2250a_configuration-manuallines_2627469008.webp)
AN118
Rev 1.1 | Page 8 / 31
www.cmostek.com
3. Operation Settings
Figure 5. Operation Settings
Table 3. Operation Settings Parameters
Parameters
Descriptions
Default
Mode
Duty-Cycle Mode
Turn on/off the duty-cycle mode, the options are: on or
off.
On
Basic
Advanced
Sleep Time
The sleep time in duty-cycle mode, the range is from 3 to
134,152,192 ms.
3 ms
Basic
Advanced
Rx Time
The receive time in duty-cycle mode, the range is from
0.04 to 2,683,043.00 ms. The default value is different
when the Wake-On Radio (WOR) is turned on or off.
10,000.00 ms
(WOR is off) or
20.00 ms
(WOR is on)
Basic
Advanced
Rx Time Ext
The extended receive time in duty-cycle mode, the range
is from 0.04 to 2,683,043.00 ms. It is only available when
the Wake-On Radio is turned on.
200.00 ms
Advanced
Rx Early Exit
Turn on/off the Rx early exit function, the options are: on
or off.
Off
Advanced
Wake-On Radio
Turn on/off the wake-on radio function, the options are:
on or off. It is only available when the Duty-Cycle Mode is
turned on.
Off
Advanced
3.1 Duty-Cycle Mode
This allows the user to determine how the radio is controlled, as shown in the figure below.
PUP
SLEEP
XTAL
TUNE
RX
Duty-Cycle Receive Mode
(
“
Duty-Cycle Mode
”
is set to On )
PUP
Always Receive Mode
(
“
Duty-Cycle Mode
”
is set to Off )
SLEEP
TUNE
RX
Figure 6. Radio Operation with Duty-Cycle Mode On and Off