AN118
Rev 1.1 | Page 16 / 31
www.cmostek.com
4. OOK Settings
Figure 18. OOK Settings
Table 8. OOK Settings
Parameters
Descriptions
Default
Mode
Demod Method
The OOK demodulation methods, the options are: Peak
TH, or Fixed TH.
Peak TH
Advanced
Fixed Demod TH
The threshold value when the Demod Method is “Fixed
TH”, the range is from 0 to 255. It is only available when
Demod Method is set to Fixed TH.
80
Advanced
Peak Drop
Turn on/off the RSSI peak drop function, the options are
on, or off.
On
Advanced
Peak Drop Step
The RSSI peak drop step size, the options are: 1, 2, 3, 5, 6,
9, 12 or 15.
2
Advanced
Peak Drop Rate
The RSSI peak drop rate, the options are: 1 step/4
symbols, 1 step/2 symbols, 1 step/1 symbols, or 1 step/0.5
symbols.
1 step/4 symbols
Advanced
4.1 Demod Method
The OOK demodulation is done by comparing the RSSI to a demodulation threshold. The threshold is an 8-bit binary value that is
comparable to the 8-bit digitized RSSI.
4.1.1 Fixed Threshold Method
When the “Demod Method” is set to Fixed TH, once the RSSI goes above the threshold, logic 1 is output as the demodulated
signal, otherwise logic 0 is output. The demodulated signal is then sent to the decoder to perform packet decoding and data pins
controlling.
0
255
User-defined
Fixed Demod TH
Demodulated
Data
Time
RSSI
Figure 19. OOK Demodulation Using Fixed Threshold