Insert tube stiffener with chemical tubing into  

corresponding chemical dispensers.  

STEP 

BLUE

RED

WHITE

STEP 

Connect 110/120V, 60HZ hard wired power 

supply to power box. 

DO NOT USE POWER 

CORD OR GFI OUTLET.

Connect dishmachine to hot water source 

recommended 140

0  

temperature (120

0

 

minimum temperature required).

STEP

2

L -1X16 / L -1X 

Quick Setup 

Instructions

ELECTRICAL 

CONNECTION 

TUBE 

STIFFENER 

CHEMICAL  

TUBING 

DRAIN HOSE 

CONNECTION 

1/2" WATER INLET 

LEVELING LEGS 

Level dishmachine by adjusting leveling legs.  

Dishmachine must be level front and back to  

ensure proper performance.  

STEP 

L-1X16 LEG 

ADJUSTER

L-1X LEG 

ADJUSTER

Connect the drain hose to wall or floor drain.  

The floor drain must have a 1 inch air gap  

between drain hose and floor drain. 

WALL DRAIN 

FLOOR DRAIN 

1"AIR GAP 

STEP 

WARNING

: Electrical and plumbing 

connections need to be made by a
licensed service person and comply
with all Federal, State and Local 
Health, Electrical, Plumbing and
Safety codes.

5-2015

REAR VIEW

800-854-6417

HOT

NEUTRAL

GROUND