ZL-GR6150-001-V1
Installation and Connection Instruction Manual
CMA (WUHU) Robotics Company Limited
27
The operation contents are as follows:
Replacement of structural parts of equipment
Adjustment, repair or replacement of electrical system components
Maintenance of safety equipment and warning equipment
Adjustment, repair or replacement of control system components
Any other work without regard to the above
Routine maintenance work that does not conform to the routine needs to be carried out by authorized
professional service personnel, who can be contacted through the manufacturer. In addition, other
non-routine maintenance work includes dealing with emergencies, such as:
Sudden breakage
Regular maintenance
4.3.1 Replace the fuse
The following table gives the code number of fuse (fuse core) and possible trouble:
Steps of replacing fuse (fuse core)
Turn off the power supply of the electric
cabinet and open the cabinet door.
Locate the fuse and replace it.
Fuse FU11 and FU12 are above the
transformer.
Replace fuse 1
label
Fault
FU11
The main power of the cabinet is not connected
FU12
The cabinet fails to connect
FU32
The mobile panel or monitor cannot be turned on
FU33
Conveyor synchronous encoder cannot count
System management encoder cannot count
There is no voltage output signal on the junction box
FU34
Robot I / O module not powered up
FU35
External device input failure