15
Onboard Charger Operation
QUIQ HIGH FREQUENCY CHARGER
CHARGER DISPLAYS
10-LED display on charger:
2379
Figure 15-4
10–LED Display on Charger
_
LED Color
Icon
Indication
(following
“Power-On Self
Test”)
STATUS EXPLANATION
Solid:
Displays approximate scale of current output during bulk phase.
Ammeter (Amber)
Flashing:
High internal charger temperature. Output reduced. Also displays algorithm
#1 through # 6 for 11 seconds if no battery is connected.
Solid:
Bulk charge phase complete, 80% charged. In Absorption phase.
80% Charge
(Amber)
Flashing:
1.
With no battery connecte, indicates algorithm # selected by number of
flashes.
2.
With battery connected, indicates battery being charged.
TABLE CONTINUED ON NEXT PAGE