Club Cannon QUAD JET Скачать руководство пользователя страница 11

Club Cannon products (the “Product”) are meant to be 

used to create special effects.  Any use of these Products 

shall be in accordance with the Terms and Conditions 

presented at the time of sale, and as they appear in this 

manual. Any misuse or abuse of this Product can be 

extremely dangerous.

DANGER

CO₂ 

SETUP

1

2

3

4A

4B

Note:

 After use, close the valve on the CO₂ tank. Clear the remaining gas through the 

product, depleting all pressure in the system. Once the product is de-pressurized, 
you can safely detach the hose from the tank and product.

1. 

Attach the female quick connect fitting on the hose, to the male 

quick connect fitting on the product. Pull back the sleeve and apply 
slight force to mate the connectors. 

2. 

Place the plastic washer inside the fitting that connects to the tank, 

then attach the fitting.  Tighten with the supplied tool, or any adjustable 
wrench (1 1/8”).

3. 

Position your CO₂ tank in a nearby location. Make sure the tank is 

stable, and won’t tip over.  Tanks should be secured with ratcheting 
straps or chain to ensure they are secure.

4. 

After attaching and tightening all fittings, turn on your CO₂ tank and 

check for any leaks. If a leak is present, cease use immediately and 
contact Club Cannon. Trigger the unit each time you want to release 
CO2.

FAILURE TO INSTALL WASHER WILL RESULT IN A LEAK

UNSTABLE TANKS CAN BE EXTREMELY DANGEROUS

THIS STEP MUST OCCUR BEFORE PRESSURIZING SYSTEM

 Club Cannon, LLC accepts no responsibility or liability for damages or injuries 

caused by misuse or abuse of the Product.  

9

Содержание QUAD JET

Страница 1: ...User Manual VERSION 1 0 AUG 2021...

Страница 2: ...GUIDE 4 SAFETY RADIUS 4 SAFE MOUNTING 5 HARDWARE OVERVIEW 6 UNIT REAR 6 HARDWARE SPECIFICATIONS 7 CO2 REQUIREMENTS 8 CO2 SETUP 9 QUICK START GUIDE 10 HOME SCREEN 11 MODE SELECTION 11 HOME STATES 12 P...

Страница 3: ...adJet in 4 channel DMX mode independent control of each output nozzle can be achieved Triggering CH 1 2 3 or all 4 channels at once will have different effect heights TIP User can also elect to use th...

Страница 4: ...lubcannon com QUAD JET TRUE1 CABLE 4 CO ATTACHMENT TOOL THIS GUIDE 20 CO WASHERS 4 CO2 HOSE Four nozzle Co2 Jet 6 Edison to True1 cord Used to tighten the CGA 320 fitting to your CO2 tank A link to th...

Страница 5: ...f and the remaining gas has been cleared through the product depleting all pressure in the system If a leak is detected cease use of the product immediately Never stand directly over unit while under...

Страница 6: ...times while operating this product Special care must be taken when preformers are near units Always inform performers staff and event personel that may inadvertantly enter the safety radius of this p...

Страница 7: ...VER mount to flown hung truss due to recoil force INVERTED MOUNTING Inverted mounting is NOT recommended Due to the large output from this unit the minimum safety radius must be followed Unless this i...

Страница 8: ...Con cable DMX Standard NEUTRIK 5 Pin XLR Connectors 1 Channel All nozzles trigger as one 4 Channel Individual control of each nozzle HARDWARE OVERVIEW 2 4 INCH LCD TOUCH SCREEN 4 x CLUB CANNON BARRELS...

Страница 9: ...240v AC 50 60hz DIMENSIONS 11 75 x 11 75 x 13 125 298mm x 298mm x 333mm CONSUMPTION 125W MAX Approx 25W Per Nozzle TRUSS MOUNTS 1 2 13 truss bolt required Nut pre installed in base CO2 CONSUMPTION 0...

Страница 10: ...The effect works best in humid environments Anytime humidity levels are 25 or below the fog will appear noticeably thinner Use the weather app on your phone to check your local humidity level TEMPERAT...

Страница 11: ...eeve and apply slight force to mate the connectors 2 Place the plastic washer inside the fitting that connects to the tank then attach the fitting Tighten with the supplied tool or any adjustable wren...

Страница 12: ...addressing Each set of arrows independantly controls the above digit Note Max available address on 4CH mode is 509 3 ATTACH HOSES Follow the steps outlined in CO SETUP GUIDE for proper CO2 setup Read...

Страница 13: ...to setting the DMX address The main menu can be accessed by tapping on the DMX address This is the default screen that is shown when the Quad Jet is first powered on STATUS BAR INCREASE DIGIT DECREASE...

Страница 14: ...he address will be displayed in red The display will dim when idle for 30 seconds with active DMX signal When DMX is being received the address will be displayed in green If screen is tapped when in i...

Страница 15: ...efore purging warn anyone nearby There will be a 5 second delay after activating the purge lines feature This allows the user sufficient time to step away from the unit All valves will be opened for 1...

Страница 16: ...eaks are present Ensure no particles or contaminates are present inside the female quick connector Check for any damage to black O ring Leak from tank connection Ensure a CO2 washer has been inserted...

Страница 17: ...ctronic device sensitive to moisture To avoid risk of electronicshock malfunction or voidedwarranty onlyuseindryenvironments Do not operate in harsh weather conditions Do not block or insert anything...

Страница 18: ...Page left blank intentionally 16...

Страница 19: ...Excluding any services provided to you by the Company under a separate written agreement these Terms and Conditions constitute the entire agreement between you and the Company regarding the use of th...

Страница 20: ...CONTACT US 856 Ricardo Ct San Luis Obispo CA 93401 888 804 8175 info clubcannon com www clubcannon com CLUB CANNON 2021 18...

Отзывы: