NOTICE

CO₂ 

REQUIREMENTS

SIPHON CO₂

 

 TANK REQUIRED.

Liquid CO₂ is the key to creating large plumes of fog. Gaseous 
CO₂, which comes from a non-siphon CO₂ tank, will 

not

 create the 

desired fog effect. 
 
The siphon tube feeds the Club Cannon product liquid from the 
bottom of the tank, while a standard CO₂ tank draws gas from the 
top of the tank (see illustration). 
 
If your tank is full, but not producing fog, you most likely have 
the wrong type of tank. Ask your gas supplier to exchange it for 
a siphon model. 

Once the fog starts to appear thin, your tank is 

depleted of liquid. It is now time to get a refill.

HUMIDITY

The effect works best in humid environments. Anytime humidity 
levels are 25% or below, the fog will appear noticeably thinner. 
Use the weather app on your phone to check your local humidity 
level.

TEMPERATURE

To ensure reliable operation of your product, keep tanks out of 
direct sunlight. Maximum tank temperature is 80 degrees F. When 
the tank temperature is above 80F, the pressure increases and 
can affect operation.

Where can I buy CO₂?

 

CO2 can be purchased from any local gas or welding supplier. 
 
Click here to find the nearest MATHESON location. 
Click here to find the nearest PRAXAIR location. 
Click here to find the nearest AIRGAS location.

Failure to use a siphon tank will prevent the product from producing the desired 
effect. If the product is firing clear gas and not fog, this is likely the cause.

8

Содержание QUAD JET

Страница 1: ...User Manual VERSION 1 0 AUG 2021...

Страница 2: ...GUIDE 4 SAFETY RADIUS 4 SAFE MOUNTING 5 HARDWARE OVERVIEW 6 UNIT REAR 6 HARDWARE SPECIFICATIONS 7 CO2 REQUIREMENTS 8 CO2 SETUP 9 QUICK START GUIDE 10 HOME SCREEN 11 MODE SELECTION 11 HOME STATES 12 P...

Страница 3: ...adJet in 4 channel DMX mode independent control of each output nozzle can be achieved Triggering CH 1 2 3 or all 4 channels at once will have different effect heights TIP User can also elect to use th...

Страница 4: ...lubcannon com QUAD JET TRUE1 CABLE 4 CO ATTACHMENT TOOL THIS GUIDE 20 CO WASHERS 4 CO2 HOSE Four nozzle Co2 Jet 6 Edison to True1 cord Used to tighten the CGA 320 fitting to your CO2 tank A link to th...

Страница 5: ...f and the remaining gas has been cleared through the product depleting all pressure in the system If a leak is detected cease use of the product immediately Never stand directly over unit while under...

Страница 6: ...times while operating this product Special care must be taken when preformers are near units Always inform performers staff and event personel that may inadvertantly enter the safety radius of this p...

Страница 7: ...VER mount to flown hung truss due to recoil force INVERTED MOUNTING Inverted mounting is NOT recommended Due to the large output from this unit the minimum safety radius must be followed Unless this i...

Страница 8: ...Con cable DMX Standard NEUTRIK 5 Pin XLR Connectors 1 Channel All nozzles trigger as one 4 Channel Individual control of each nozzle HARDWARE OVERVIEW 2 4 INCH LCD TOUCH SCREEN 4 x CLUB CANNON BARRELS...

Страница 9: ...240v AC 50 60hz DIMENSIONS 11 75 x 11 75 x 13 125 298mm x 298mm x 333mm CONSUMPTION 125W MAX Approx 25W Per Nozzle TRUSS MOUNTS 1 2 13 truss bolt required Nut pre installed in base CO2 CONSUMPTION 0...

Страница 10: ...The effect works best in humid environments Anytime humidity levels are 25 or below the fog will appear noticeably thinner Use the weather app on your phone to check your local humidity level TEMPERAT...

Страница 11: ...eeve and apply slight force to mate the connectors 2 Place the plastic washer inside the fitting that connects to the tank then attach the fitting Tighten with the supplied tool or any adjustable wren...

Страница 12: ...addressing Each set of arrows independantly controls the above digit Note Max available address on 4CH mode is 509 3 ATTACH HOSES Follow the steps outlined in CO SETUP GUIDE for proper CO2 setup Read...

Страница 13: ...to setting the DMX address The main menu can be accessed by tapping on the DMX address This is the default screen that is shown when the Quad Jet is first powered on STATUS BAR INCREASE DIGIT DECREASE...

Страница 14: ...he address will be displayed in red The display will dim when idle for 30 seconds with active DMX signal When DMX is being received the address will be displayed in green If screen is tapped when in i...

Страница 15: ...efore purging warn anyone nearby There will be a 5 second delay after activating the purge lines feature This allows the user sufficient time to step away from the unit All valves will be opened for 1...

Страница 16: ...eaks are present Ensure no particles or contaminates are present inside the female quick connector Check for any damage to black O ring Leak from tank connection Ensure a CO2 washer has been inserted...

Страница 17: ...ctronic device sensitive to moisture To avoid risk of electronicshock malfunction or voidedwarranty onlyuseindryenvironments Do not operate in harsh weather conditions Do not block or insert anything...

Страница 18: ...Page left blank intentionally 16...

Страница 19: ...Excluding any services provided to you by the Company under a separate written agreement these Terms and Conditions constitute the entire agreement between you and the Company regarding the use of th...

Страница 20: ...CONTACT US 856 Ricardo Ct San Luis Obispo CA 93401 888 804 8175 info clubcannon com www clubcannon com CLUB CANNON 2021 18...

Отзывы: