The ambient temperature is high. 

It is normal for the cooler to run 
continuously at high ambient temperatures. 

C. The cooler 
compressor runs 
continuously, but I do 
not have cold water. 

There has been a substantial loss in the 
sealed system's charge of refrigerant. 

If refrigerant leak is suspected, return 
cooler to authorized service center or 
factory for repair. 

The compressor is defective. 

Same as above. 

HOT WATER SYSTEM

 

A. The hot water is not 
hot. 

If cooler equipped with hot water switch 
may be OFF. 

Turn the hot water switch ON. 

There is a loose or broken wire connection 
in the hot water system. 

Identify the loose or broken wire 
connection, repair as necessary. 

The hot control is defective. 

Replace the hot control. 

The heat limiter is "ON". 

Push "Reset" button of heat limiter. 

The hot tank heater is defective. 

Replaced the hot tank heater or hot tank 
assembly. 

B. The hot water is 
hot, but not hot 
enough. 

Usage of the hot water system is greater 
than its capacity. 

Inform the customer of the hot water 
system's maximum capacity. 

The hot control is defective. 

Replace hot control. 

C. The hot water flows 
slowly or not at all. 

Hot water flow is designed to flow slowly 
than cold and cook water to prevent 
splashing. 

Advice the customer of this safety feature. 

Defective faucet. 

Replace faucet. 

Hot tank plugged with mineral deposits. 

De-lime tank. 

D. Hot tank is noisy. 

The hot tank heater is caked with mineral 
deposits. 

Slight boiling sound normal during heating 
cycle. De-lime tank. 

NOISE

 

A. There is excessive 
noise coming from the 
cooler, but it is 
otherwise operating 
normally. 

The cooler is not level. 

The cooler must be leveled. 
Place the cooler on even surface. 

A section of the tubing inside the cooler is 
touching other parts of cooler, causing 
noise to be generated due to vibration. 

Adjust position of the tubing to make sure it 
is not in contact with any other parts. 

Check the connection of the fixed screws. 

Completely connect the fixed screws. 

The compressor's operation is noisy 
because of inherent conditions. 

Advise the customer of the cooler's normal 
operating sounds. 

WATER LEAKAGE

 

A. Water drips from 
faucet. 

The faucet body packing and spring is 
defective. 

Press down the faucet lever several times.   
Replace faucet assembly. 

B. Leakage through 
inside or outside of 
appliance. 

The faucet is not completely connected. 

Properly connect the faucet. 

C. Water drips from 
dual float valves 

The dual float valves elbow union is 
defective. 

Replace the dual float valves elbow union. 

Содержание b9a

Страница 1: ...before servicing the watercooler 1 Check if an electric leakage occurs in the appliance 2 To prevent electric shock unplug prior to servicing 3 In case of testing with power on wear rubber gloves to p...

Страница 2: ...TEMP CONTROL AUTO TANK Stainless Steel CAPACITY 2 7 h 10 HOT CONSUMPTION 465W PROTECTOR Heat Limiter TEMP CONTROL Hot Control TANK Stainless Steel CAPACITY 7 5 h 85 ELECTRICAL 220 240V 50 60Hz 110 127...

Страница 3: ...tor Absorbs the surrounding heats while evaporating the liquid refrigerant cools down water inside of cold water tank Cold water thermostat Senses the temperature of cold water tank and controls the e...

Страница 4: ...ICAL DAMAGE TO THE COOLER F Cooler will be ready to serve you Cold Hot water in 30 minute after installation G Hot Water Safety Faucet A safety faucet deters accidental dispensing of water by toddlers...

Страница 5: ...e abrasive or wire brush L Follow Installation Procedures to operate the cooler 7 TROUBLESHOOTING GUIDE TROUBLE POSSIBLE CAUSE REMEDY REFRIGERATION SYSTEM A Compressor does not run No electric power t...

Страница 6: ...w is designed to flow slowly than cold and cook water to prevent splashing Advice the customer of this safety feature Defective faucet Replace faucet Hot tank plugged with mineral deposits De lime tan...

Страница 7: ...ly Wait until the cold water tank is filled with water after a large draw due to inherent restriction of the Non Spill System Air filter is wet Allow filter to dry Airflow through the filter will grad...

Страница 8: ...8...

Страница 9: ...9...

Страница 10: ...10...

Страница 11: ...11...

Отзывы: