- 5 -
C.
Remove faucets from the product. Both faucets are disassembled by turning them counter clockwise.
D.
Wear disposable gloves (clean and safe material for drinking water).
E.
Wash the faucets, drip tray with mild soap and water. Then, rinse them with clean water immediately.
F.
Cleanse interior of cold water tank with a clean dish towel.
Do not use bleach or any cleaning agents containing bleach or chlorine.
G.
Assemble drip tray, grid, faucets and baffle.
H.
Pour clean water into cold water tank and open cold faucet to flush the entire water trail. Repeat this step at
least three times. Then, close the faucet.
Steps I, J are for Hot & Cold model only.
I.
Open hot water faucet. Then, until the water flow from hot water faucet is continuous and clear, pour clean
water into cold water tank. Then, close the faucet.
J.
Open drain cap to flush water trail in hot water tank.
Repeat this step at least three times and close the drain cap at the end.
K.
Brush out and vacuum the dirt and dust from condenser. Do not use abrasive or wire brush.
L.
Follow Installation Procedures to operate the cooler.
7. TROUBLESHOOTING GUIDE
TROUBLE
POSSIBLE CAUSE
REMEDY
REFRIGERATION SYSTEM
A. Compressor does
not run.
No electric power to outlet.
Turn on electric power outlet.
The thermostat is misadjusted or defective.
Adjust or replace the thermostat, as
necessary.
The wires leading to the thermostat are
defective or are not connected.
Check the internal wiring.
Make repairs as necessary.
The line voltage is low.
Check the line voltage. It must be at least
90% of minimum voltage.
The compressor over-load
Protector (OLP) is defective.
Replace the defective over-load protector.
The starting relay (PTC) is defective.
Replace the starting relay.
The compressor is defective.
Replace the compressor.
Return cooler to authorized service center
or factory for repair.
B. Water is adequately
chilled, but cooler runs
excessively or
continuously.
Poor ventilation.
Minimum side & rear clearance 4"
The condenser is dirty or restricted.
Clean the condenser or relocate the unit to
prevent restricting the condenser.
The thermostat is defective. (the contacts
are shorted or the control is not adjusted
properly)
Replace or adjust the thermostat as
necessary.