A. Cooling Operation 

The vapor refrigerants that compressed to high temperature & high pressure conditions in the compressor, turn 

into liquid refrigerant of high temperature and high pressure passing through the condenser, and then turn into 

the liquid refrigerants of  low temperature and  low pressure conditions by passing through the  capillary tubes. 

The liquid refrigerant of low temperature & low pressure absorbs the surrounding heat while evaporating in the 

evaporator. Then, it is sucked in the compressor by turning into saturated vapor. 

 

B. Heating Operation 

The  electric  heater  inside  of  the  hot  water  tank  heats  the  supplied  water.  The  temperature  of  hot  water  is 

controlled  by  the  hot  control  at  a  proper  temperature.  In  case  of  overheating,  the  heat  limiter  will  operate 

automatically. 

 

C. Function of Parts 

 

Compressor: Compresses the vapor refrigerant sucked from the evaporator and discharges it to condenser 

 

Condenser: Changes the compressed vapor refrigerant into the liquid refrigerant by cooling. 

 

Drier: Removes moisture and dirt inside pipes 

 

Capillary  tube:  Reduces  the  pressure  of  liquid  refrigerant  and  evaporates  it  in  the  evaporator  under 
constant pressure. 

 

Evaporator: Absorbs the surrounding heats while evaporating the liquid refrigerant, cools down water inside 
of cold water tank. 

 

Cold water thermostat: Senses the temperature of cold water tank and controls the electric power supply to 
the compressor automatically in order to keep the constant temperature of cold water. 

 

Over Load Protector (OLP): Protects the compressor and operates when rising up to abnormal temperature 
or energizing over current.   

 

PTC Starter: Starts up the motor of compressor.   

 

Cold  water  baffle:  Separates  the  supplied  water  from  cold  water,  hot  water,  or  room  temperature  water 
respectively. 

 

Hot tank heater: Heats the supplied room temperature water to hot water. 

 

Hot control: Controls the temperature of hot water at a proper automatically. 

 

Heat limiter: Cuts off the electric power to the heater in case of overheating. 

 

Hot water switch: Supplies or cuts off the electric power to the heater by setting it ON/OFF. 

 

Drain cap: By opening this, you may drain out remaining water in hot water tank when cleaning or not using 
cooler for a long period of time. 

 

3. LOCATION REQUIREMENTS 

A.

 

Locate cooler in a well ventilated space where temperature is never below 0

B.

 

Maintain a minimum clearance of 4 inches on sides and rear of cooler for proper ventilation. 

C.

 

Make  sure  installation  ground  is  flat  and  even.  -  Unbalanced  placement  may  cause  excessive  noise  and 

trembling of the cooler. 

Содержание b9a

Страница 1: ...before servicing the watercooler 1 Check if an electric leakage occurs in the appliance 2 To prevent electric shock unplug prior to servicing 3 In case of testing with power on wear rubber gloves to p...

Страница 2: ...TEMP CONTROL AUTO TANK Stainless Steel CAPACITY 2 7 h 10 HOT CONSUMPTION 465W PROTECTOR Heat Limiter TEMP CONTROL Hot Control TANK Stainless Steel CAPACITY 7 5 h 85 ELECTRICAL 220 240V 50 60Hz 110 127...

Страница 3: ...tor Absorbs the surrounding heats while evaporating the liquid refrigerant cools down water inside of cold water tank Cold water thermostat Senses the temperature of cold water tank and controls the e...

Страница 4: ...ICAL DAMAGE TO THE COOLER F Cooler will be ready to serve you Cold Hot water in 30 minute after installation G Hot Water Safety Faucet A safety faucet deters accidental dispensing of water by toddlers...

Страница 5: ...e abrasive or wire brush L Follow Installation Procedures to operate the cooler 7 TROUBLESHOOTING GUIDE TROUBLE POSSIBLE CAUSE REMEDY REFRIGERATION SYSTEM A Compressor does not run No electric power t...

Страница 6: ...w is designed to flow slowly than cold and cook water to prevent splashing Advice the customer of this safety feature Defective faucet Replace faucet Hot tank plugged with mineral deposits De lime tan...

Страница 7: ...ly Wait until the cold water tank is filled with water after a large draw due to inherent restriction of the Non Spill System Air filter is wet Allow filter to dry Airflow through the filter will grad...

Страница 8: ...8...

Страница 9: ...9...

Страница 10: ...10...

Страница 11: ...11...

Отзывы: