4.1 The setting of current
Peak Current
Average Current
SW1
SW2
SW3
Remarks
1.0A
0.7A
on
on
on
Other Current
can be
custom-made.
1.5A
1.1A
off
on
on
2.0A
1.4A
on
off
on
2.5A
1.8A
off
off
on
3.0A
2.1A
on
on
off
3.7A
2.6A
off
on
off
4.3A
3.0A
on
off
off
5.0A
3.5A
off
off
off
DIP SW1, SW2, SW3 are used to set current which is output from drive to motor.
Generally, the current setting is the motor rated current. If your system has high request to the heating, please
decrease the current properly to lower the motor’s heating, but at the same time, the output torque will be
lower. If you don’t need the motor running continuous, you can increase the current to higher the torque. But be
minded that the current can not be 1.5times over than the rated current.
4.2 The setting of pulse per revolution
Stepping
count/revolution
SW5
SW6
SW7
SW8
Remarks