background image

DM542S

USER MANUAL

www.cloudratmotor.com

5

When central tapping used, half of the winding connected, and the inductance was lower. This is suitable for high
speed required.

3.4 Control signal connection

3.4.1 PUL, DIR port: connection for pulse command

The signal interface of standard DM series drive is

switch.

The upper controller can be the pulse signal generating device, such as PLC, MCU, control card and controller.

The pulse level that DM 542S drive can be used: 3.3V-24V (

no need to connect resistor

)

Pulse&Direction

PUL + DIR

Dual Pulse

CW +CCW

Orthogonal Pulse

A/B

3.4.2

ENA port: used to enable or disable

When the default optocoupler is off, the driver outputs current to the motor. When the internal optocoupler is
turned on, the driver will cut off the current of each phase of the motor to make the motor free. At this time, the
step pulse is not responded.

The ENA input can be used to restart the drive when the motor is in an error state. First, the existing fault should
be eliminated, and then a falling edge signal is input to the ENA terminal, and the drive can be re-energized.

The level logic of the ENA signal can be set to the opposite, with the logic being opposite to the above.

4.

The setting of DIP switches and operating parameters

The setting of current

Semi / Full current option

The setting of pulse per revolution

SW1

SW2

SW3

SW4

SW5

SW6

SW7

SW8

Содержание DM542S

Страница 1: ...DM542S USER MANUAL www cloudratmotor com DM542S USER MANUAL...

Страница 2: ...1Port function description 3 3 2 Power supply input 3 3 3 Motor connection 4 3 4 Control signal connection 5 3 4 1 PUL DIR port connection for pulse command 5 3 4 2 ENA port used to enable or disable...

Страница 3: ...rent protection Its input and output control signals are optically isolated Power supply 24 50VDC Output Current Up to 5 0 amps peak value Current control PID current control algorithm Micro stepping...

Страница 4: ...tall the drive vertically or horizontally with its front facing forward top facing upward to facilitate cooling During assembly avoid drillings and other foreign matters falling inside the drive Durin...

Страница 5: ...constant current control The drive output the voltage to motor by changing the input power into PWM chopping wave when it is working In this case the input power will affect the performance of drive...

Страница 6: ...6 B B A A NC NC The matching motor of the DM 542S drive is the low resistance and low inductance hybrid stepper motor The common 2 phase stepper motor s lead number are 4 8 and 6 There is only one con...

Страница 7: ...used to enable or disable When the default optocoupler is off the driver outputs current to the motor When the internal optocoupler is turned on the driver will cut off the current of each phase of t...

Страница 8: ...DM542S USER MANUAL www cloudratmotor com 6 3 4 3 Control signal wiring example Common anode Common cathode Difference...

Страница 9: ...to set current which is output from drive to motor Generally the current setting is the motor rated current If your system has high request to the heating please decrease the current properly to lowe...

Страница 10: ...e motor stops Off means that when the drive power on pulse stops the driver switches the current output to the motor to half of the rotation half flow On indicates that the drive maintains the same cu...

Страница 11: ...of motor is reverse Adjust the DIP SW5 The motor cable is disconnected Check the connection The motor has only one direction Pulse mode error or DIR port damaged Alarm indicator is on The motor conne...

Страница 12: ...rantee Clause A 1 Warranty period 12 months We provide quality assurance for one year from the date of delivery and free maintenance service for our products during the warranty period A 2 Exclude the...

Отзывы: