One green and five red indicators

Encoder phase error

6. Common Faults and Troubleshooting

Phenomenon

Possible situations

Solutions

Motor does not work

Power indicator is off

Check the power supply circuit for normal
power supply

The motor rotor is locked but the
motor does not work

Pulse signal is weak; increase the signal current
to 7-16mA

The speed is too slow

Select the right micro-stepping

Drive is protected

Solve the alarm and re-power

Enable signal problem

Pull up or disconnect the enable signal

Command pulse is incorrect

Check whether the upper computer has pulse
output

The steering of motor
is wrong

The rotary direction of motor is
reverse

Adjust the DIP SW5

The motor cable is disconnected

Check the connection

The motor has only one direction

Pulse mode error or DIR port damaged

Alarm indicator is on

The motor connection is wrong

Check the motor connection

The motor connection and encoder
connection are wrong

Check the sequence of encoder connection

The voltage is too high or too low

Check the power supply

The position or speed
is wrong

The signal is disturbed

Eliminate interference for reliable grounding

The command input is incorrect

Check the upper computer instructions to
ensure the output is correct

The setting of Pulse per revolution is
wrong

Check the DIP switch status and correctly
connect the switches

Encoder signal is abnormal

Replace the motor and contact the
manufacturer

The drive terminal

Short circuit between terminals

Check power polarity or external short circuit

Содержание DM542S

Страница 1: ...DM542S USER MANUAL www cloudratmotor com DM542S USER MANUAL...

Страница 2: ...1Port function description 3 3 2 Power supply input 3 3 3 Motor connection 4 3 4 Control signal connection 5 3 4 1 PUL DIR port connection for pulse command 5 3 4 2 ENA port used to enable or disable...

Страница 3: ...rent protection Its input and output control signals are optically isolated Power supply 24 50VDC Output Current Up to 5 0 amps peak value Current control PID current control algorithm Micro stepping...

Страница 4: ...tall the drive vertically or horizontally with its front facing forward top facing upward to facilitate cooling During assembly avoid drillings and other foreign matters falling inside the drive Durin...

Страница 5: ...constant current control The drive output the voltage to motor by changing the input power into PWM chopping wave when it is working In this case the input power will affect the performance of drive...

Страница 6: ...6 B B A A NC NC The matching motor of the DM 542S drive is the low resistance and low inductance hybrid stepper motor The common 2 phase stepper motor s lead number are 4 8 and 6 There is only one con...

Страница 7: ...used to enable or disable When the default optocoupler is off the driver outputs current to the motor When the internal optocoupler is turned on the driver will cut off the current of each phase of t...

Страница 8: ...DM542S USER MANUAL www cloudratmotor com 6 3 4 3 Control signal wiring example Common anode Common cathode Difference...

Страница 9: ...to set current which is output from drive to motor Generally the current setting is the motor rated current If your system has high request to the heating please decrease the current properly to lowe...

Страница 10: ...e motor stops Off means that when the drive power on pulse stops the driver switches the current output to the motor to half of the rotation half flow On indicates that the drive maintains the same cu...

Страница 11: ...of motor is reverse Adjust the DIP SW5 The motor cable is disconnected Check the connection The motor has only one direction Pulse mode error or DIR port damaged Alarm indicator is on The motor conne...

Страница 12: ...rantee Clause A 1 Warranty period 12 months We provide quality assurance for one year from the date of delivery and free maintenance service for our products during the warranty period A 2 Exclude the...

Отзывы: