CL7206C reader only supports two GPO outputs, that is "1" and "2".
Select the high / low level, click this configuration to execute settings after modify.
4.5.13 Advanced configuration
Weigand configuration
Select “configuration” on the main interface > "GPI/O configuration" > “Weigand "then pop-up dialog box, as
shown in image 4-30:
Image 4-30 Weigand configuration
In the Weigand parameter settings area, set up the “communication switch” for the "open" state, and select
the corresponding "communication format" and "transmission data content", click on the "configuration" to
determine.
Weigand port Parameter configuration: includes “Weigand 26, “Weigand 34" and “Weigand 66"models.
Weigand 26: TID or EPC data reported from the end of the Weigand port is valid for 3 bytes.
Weigand 34: TID or EPC data reported from the end of the Weigand port is valid for 4 bytes.
Weigand 66: TID data reported from the end of the Weigand port is valid for 8 bytes.
Restore factory settings
Select “configuration” on the main interface > “restore factory settings” then pop-up dialog box, as shown in
image 4-31: