UNIT POWER-UP
Set the welding power source ON/OFF switch to “I” to switch on the unit.
AL. HEA.
The message appears on the following displays: D1-D2
x.x= software version
First power-up or power-ups following a RESET procedure
The welding power source sets up for welding with the factory presets.
Subsequent power-ups
The welding power source sets up for welding in the latest stable welding configuration that was active at the time of power-off.
3.3
RESET (LOAD FACTORY SETTINGS)
The reset procedure involves complete restoration of the default values, parameters and memory settings set in the factory.
The reset procedure is useful in the following cases:
-
Too many changes made to the welding parameters so user finds it difficult to restore defaults.
-
Unidentified software problems that prevent the welding power source from functioning correctly.
3.3.1
PARTIAL RESET
The reset procedure involves restoration of the parameter values and settings, except the following settings:
-
Settings of the SETUP menu.
-
saved JOBS.
Set the welding power source ON/OFF switch to “O” to switch the unit off.
S1
S5
Hold down both buttons simultaneously.
Set the welding power source ON/OFF switch to “I” to switch on the unit.
SIMULTANEOUS ACTIONS
rEC PAr
The message appears on the following displays: D1-D2
Exit without confirmation
Press any button (except S5).
This action will automatically close the menu.
Exit with confirmation
S5
Press the button.
Wait for the memory clear procedure to terminate.
This action will automatically close the menu.
3.3.2
TOTAL RESET
The reset procedure involves complete restoration of the default values, parameters and memory settings set in the factory.
All memory locations will be reset and hence all your personal welding settings will be lost!
Set the welding power source ON/OFF switch to “O” to switch the unit off.
S1
S5
Hold down both buttons simultaneously.
Set the welding power source ON/OFF switch to “I” to switch on the unit.
SIMULTANEOUS ACTIONS
rEC PAr
The message appears on the following displays: D1-D2
E1
Select the following setting with the encoder:
rEC FAC
Exit without confirmation
Press any button (except S5).
This action will automatically close the menu.
Exit with confirmation
S5
Press the button.
Wait for the memory clear procedure to terminate.
This action will automatically close the menu.
Содержание GLW 322
Страница 1: ...operating instructions and spare parts GLW 322 Rev 0 EN...
Страница 8: ...GLW 322 Cod 006 0001 1861 01 09 2014 v2 0 ENGLISH 7 38 polarity to basic electrode...
Страница 10: ...GLW 322 Cod 006 0001 1861 01 09 2014 v2 0 ENGLISH 9 38 polarity for tungsten electrode...
Страница 38: ...Remote Controller Potentiometer 2k 10k Foot pedal controller Potentiometer 2k 10k...
Страница 39: ...www qineo de...