7. Maintenance / Cleaning
The Blower unit, filter housing and head units must all be regularly clea-
ned to keep them in good working order.
For single users, the units can all be cleaned with a cloth moistened with
lukewarm water and soap.
For multiple users, the units should be disinfected when passed from one
user to another.
The Manufacturer recommends that ‚Incidur‘ from Ecolab GmbH & Co.
OHG is used for disinfecting.
Liquids must not be allowed to enter the workings of the blower unit or
get on to the element of the filter.
Parts should be allowed to air dry. Under no circumstances should any
solvents or abrasive cleaning agents be used. The unit must not be dried
using hot air or radiant heat.
The unit should continue to provide protection to the designed specificati-
on for 2 to 3 years, when maintained in accordance with these instructions.
Prior to each use the user should check that the unit is free from defects,
such as cracks, split filters and hoses, cracked visors and helmet compo-
nents as appropriate