Important: When using a DSP to control the system ensure that the DSP control signal is already
outpV to Socket 3 (DSP IN) on the CCRM 4000 Main unit (+2.5 to 12 Volts) before powering
the system up. Otherwise the DSP command will not be recognised by the system and unit will fail
to operate.
3.5
Further Secondary wiring connection
For addition of further Secondary units, connect a CAT5 between Socket 4 (LINK) and Socket 3 (DSP
IN) of the next Secondary. Repeat for additional units to form a daisy chain. Ensure that each
additional CCRM 4000 unit is set with a unique address using the rotary decimal encoder e.g. “2” for
second, “3” for third, etc…
Up to 99 Secondary units can be linked together in the same / identical way.
Main / Secondary CCRM 4000 Connectivity Diagram
IR
Sensor
Bezel
DSP
Bezel
Main
unit
Secondary
unit
To next
Secondary
CCRM 4000