R
EFRIGERANT CIRCUIT ALARMS
Num
Name
Description
Category
ff2005
Min overheating EEV1
Min Superheat value (user side)
Circuit 2
ff2006
Min overheating EEV2
Min Superheat value (source)
Circuit 2
fF2009
Low Pressure Alarm (DI)
Low pressure Alarm (DI)
Circuit 2
ff2010
Warning LP Cool
Low pressure Pre Alarm CoolingMode
Circuit 2
ff2011
Warning LP Heat
Low pressure Pre Alarm HeatingMode
Circuit 2
fF2012
Low pressure Alarm Heat (AI)
Low pressure Pre Alarm Heating Mode (AI)
Circuit 2
fF2013
High Pressure (DI)
High pressure Alarm (DI)
Circuit 2
ff2014
Warning High Pressure
High pressure Pre Alarm
Circuit 2
fF2015
High Pressure Alarm (AI)
High pressure Alarm (AI)
Circuit 2
ff2016
Max RC Warning
Maximum pressure Ratio Pre Alarm
Circuit 2
fF2017
Min RC Alarm
Minimum pressure Ratio Pre Alarm
Circuit 2
fF2018
Low Pressure Alarm Cool(AI)
Low Pressure Alarm Cooling Mode
Circuit 2
FF2019
Max RC Alarm
Maximum Pressure Radio
Circuit 2
FF2034
Vacuum Circuit
Vaacum Alarm
Circuit 2
FF2046
LimLp
Low pressure limit
Circuit 2
ff2047
DFRForced
Defrost Forced
Circuit 2
ff2048
DFRWaterTLow
Low water temperature for defrost
Circuit 2
ff2049
DFRTimeMax
Defrost Time
Circuit 2
HYDRAULIC CIRCUIT ALARMS
Num
Name
Description
Category
iI0002
Water pressure
User side low water pressure
GP Ut
iI0006
Flow switch utility side
User side low flow rate
GP Ut
II0007
Freeze alarm
User side Water Frost Protection
Centrale
ii0008
Pumps antifreeze alarm
Pump activation Water Frost Protection
Centrale
II0009
Inconsistent deltaT across the exchanger
Water outlet temperature, discordant with the
current operation mode, user side
Centrale
II0042
Pressure allarm
Freecooling low water pressure
FCI Circuito 1
II0043
Freeze alarm
Freecooling water frost protection
FCI Circuito 1
ii0047
Flow switch allarm
Freecooling water low flow rate
FCI Circuito 1
iI0052
Recovery Low H2O Flow
Recovery water low flow rate
Recupero
iI0053
Recovery Low Pressure Plant
Recovery low water pressure
Recupero
iI1017
Source Low Pressure Plant
Source low water pressure
Sorgente 1
iI1020
Source Low H2O Flow
Source side low water flow
Sorgente 1
II1021
Source H2O Freeze Alarm
Source side water frost protection
Sorgente 1
iI2017
Source Low Pressure Plant
Source low water pressure
Sorgente 2
iI2020
Source Low H2O Flow
Source side low water flow
Sorgente 2
II2021
Source H2O Freeze Alarm
Source side water frost protection
Sorgente 2
41
Содержание WSH-XSC3
Страница 45: ...8 14 Compressor replacement 45...
Страница 46: ...8 15 Exchanger replacement 8 16 Pump replacement 46...
Страница 47: ...9 Accessories 9 1 Antivibration 47...
Страница 48: ...48...
Страница 61: ...Page intentionally left blank 61...
Страница 62: ...Page intentionally left blank 62...
Страница 63: ...Page intentionally left blank 63...