Commission climote HUB  (7)

 

1. Navigate to Zone Setup

 

Using the Menu/Back button and Scroll Wheel, 
select : 
1.

 

Menu. 

4. Commission  Device. 

2.

 

Settings. 

5. Zone Setup. 

3.

 

Installer Settings. 

2. Set up Zones

 

1.

 

Active zones – On or Off. Set One, two or three 
zones to “On” to match the zone configuration. 
Turn scroll wheel to change, push to select, then 
select “Next”. 

2.

 

Thermostat Settings (see Thermostat Options) 
Turn scroll wheel to change, push to select, finally 
select “Next”. 

3.

 

Select Save – this communicates the settings to 
climote ONLINE. 

Carry Out Local Checks  (6)

 

Local checks

 

1.

 

Check unit shows correct time within 1 minute 
of completing start-up sequence. If time does 
not update, follow steps for “time” in 
Diagnostics (12). 

2.

 

Press the Menu/Back button. Observe Menu 
Options are displayed. Choose Settings, Signal 
Strength. Note signal strength. 

3.

 

If signal strength is less than 25% follow steps 
for “poor signal” in Diagnostics (12). 

4.

 

Press Menu/Back 3 times to exit. 

5.

 

Press “Boost” button for Living zone. Boost 
menu is displayed, select Boost for 1 hour. 
Observe Boost light glows orange and heating 
is turned on in living zone. 

6.

 

Press Living Boost again and select Cancel 
Boost. Boost light is extinguished and heating 
is turned off in living zone. 

7.

 

Repeat for all active zones. 

Содержание HUB

Страница 1: ... Guide Special Instructions This is a mains powered device Observe safety precautions and isolate from mains before commencing installation Video Instructions Additional video instructions are available from climote on request ...

Страница 2: ...ntents Page Details 3 5 Installation Wiring and Power up 6 Functional Tests and Commissioning 7 8 Remote Access Test 9 Diagnostics 11 13 Thermostat Options 14 15 Customer Training 16 Safety Information 2 ...

Страница 3: ...3 Attach Back plate to Wall box 1 Inside the Box Back plate climote HUB Also included 1 Fixing screws 2 Quick start guide 3 Pocket guide 4 Safety information ...

Страница 4: ......

Страница 5: ... quality unit can take up to 5 minutes to complete its start up sequence Refer to Diagnostics 12 Attach Unit to Wall plate 4 Attaching the Unit 1 Ensure main body screws are fully loosened 2 Align unit directly above back plate 3 Twist down and engage hinge 4 Push firmly to close and engage clip 5 Tighten main body screws Removing the Unit 1 Isolate from mains 2 Unscrew main body screws 3 Remove s...

Страница 6: ...Out Local Checks 6 Local checks 1 Check unit shows correct time within 1 minute of completing start up sequence If time does not update follow steps for time in Diagnostics 12 2 Press the Menu Back button Observe Menu Options are displayed Choose Settings Signal Strength Note signal strength 3 If signal strength is less than 25 follow steps for poor signal in Diagnostics 12 4 Press Menu Back 3 tim...

Страница 7: ...de of access requires Flash to be supported by the device browser Send Test Phone Message 8 1 Text to Device Mobile Number Boost Living 1 3 Receive Text from Device Mobile Number Climote Message Climote Hub LIVING 19 8C ON BED OFF WATER OFF Wed 16 24 36 2 Observe unit Living Zone Boost is on 5 Observe unit Living Zone Boost is off 4 Text to Device Mobile Number Cancel Living Boost The Device Mobil...

Страница 8: ...d Report Observe Boost is shown on thedevice Check Zone settings reflect what you set on the device Adjust status and rename zones ifrequired Other settings grants temporary access to the user s climote web site but only until the user has registered Be sure to Save changes on this page They will then be communicated to the device At this stage the unit is commissioned and ready for user registrat...

Страница 9: ...he signal strength shows below 25 even if start up completes normally you may need to fit an external antenna Check the signal strength and if in doubt contact climote 4 Unable to register to Website If manual SMS works but the Installer Website test rejects the unit first check the Device Mobile Number and Serial number have been entered correctly If it still fails the unit may not have successfu...

Страница 10: ...10 Notes ...

Страница 11: ... Number Reset button Top 2 Climote DEGREE 1 Open climote DEGREE 2 Select desired location and affix climote DEGREE back plate to wall see Location T3 3 Note serial number last 6 digits 4 Remove Battery Tab Battery Tab Back plate 1 Climote HUB 1 Ensure climote HUB is fitted and installed in line with Installation Guide ...

Страница 12: ...imote HUB T2 1 Navigate to Zone Setup Using the Menu Back button and Scroll Wheel select 1 Menu 2 Settings 3 Installer Settings 4 Commission Device 5 Zone Setup 2 Set up Zones and Thermostats Select 1 Active zones On or Off see Setup T5 Turn scroll wheel to change push to select select Next 2 Thermostat Settings see Setup T5 Turn scroll wheel to change push to select Next 3 Select Save this commun...

Страница 13: ... the LED 2 or 3 flashes show batteries are OK 2 Repeat the auto pairing process in 3 Check whether the climote HUB is receiving data from the climote DEGREE If in doubt try manual pairing 3 Check signal level is greater than 10 If not look for an alternative location for climote DEGREE 4 If problems persist contact climote Pair climote DEGREE T4 Reset button 1 Enable PairingMode From the Commissio...

Страница 14: ...video instructions are available at www climote com Unit Text Demonstration 1 3 Text Demonstration Boost 1 Get customer to add Device Mobile Number to contacts 2 Show Customer Useful Text Functions card 3 Repeat SMS Boost from installation test 2 Boost Demonstration 1 Explain Boost 2 Do example Boost Living 3 Disable Boost 1 Explain the basic unit features 1 Zones and Dashboard 2 Boost and Menu Ba...

Страница 15: ...act number 2 Enter Device Mobile Number 5 Optionally user can add a password 3 Enter a first name for this user 6 Press submit to Register 1 Ask the customer to navigate to www climote ie 2 Select Control my climote 3 From the climote log in page choose the option to please register here App Demonstration 4 1 Explain dashboard Menu button and status indicators 3 Press zone dial and show App Edit 2...

Страница 16: ...hock Protec8on Class II The climote HUB is completely protected by its enclosure Installa8on The unit must be installed by a qualified electrician N 0 L 0 _ L0 6 K Power Supply 3V DC 2AA Baderies supplied Power Consump8on 0 01W 3mA Model Climote DEGREE TEK676 2pera8ng Temperature 0 to 40 degrees C Unit conforms to EN60730 1 2000 EN60730 2 7 when used with climote HUB climote limited Telephone 353 0...

Отзывы: