![Climax Vesta ESGW Series Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/climax/vesta-esgw-series/vesta-esgw-series_installation-manual_2624893022.webp)
19
5.3. Walk Test
This is to test the sensor operation range for installation purpose.
Step 1.
Click on
“
Start
”. The system will automatically exit the test mode after 5 minutes
Step 2.
Press the test button on the sensor(s) or any button on the Remote Controller (Please
refer to your sensor manual for detail.)
Step 3.
When the Control Panel receives a signal, it will show the information listed below to
indicate that it is safe to install the particular sensor in the location.
Time
: time informaiton
Area
: operation area
Zone
: device zone
Type
:
device type
Name
:
device name
Rssi
: the signal strength between Control Panel and sensor. The Rssi value here must
be higher than the Rssi value of Panel
’s background noise (please refer to
6.1
Panel
Condition section for details
). If not, you may still learn in the sensor; however, please
relocate the sensor and use Walk test to find a more suitable location.
DeviceID
: device
’s unique identification code.
Step 4.
Once all sensors are tested, click on
“
Stop
” to exit Walk Test mode.
Содержание Vesta ESGW Series
Страница 1: ...November 28 2019...