4.1.4. Setting
The Setting tab allows you to program general configuration for Mobile Lite.
Click “Write” when you have completed all settings to confirm.
Guard Time:
When the Active Button on Mobile Lite is pressed, the device will
play voice prompt “Initiating Help” and enter guard time.
During guard time, the device will emit one beep every second. After
Guard Time expires, Mobile Lite will begin report.
Guard Time Fall Sensor:
The Guard Time for Fall Sensor’s fall detection function is set
separately from regular Guard Time.
After the Guard Time Fall Sensor expires, Mobile Lite will begin
report.
This function is only used when a fall is detected, if the Active Button
on Mobile Lite or the Active Button of the learnt-in Fall Sensor is
pressed to activate alarm, normal guard time is used instead.
Fall Sensor Sensitivity:
Select a preferred sensitivity level for the learned-in Fall Sensor FS-3.
(5 is the highest sensitivity level while 1 is the lowest sensitivity
level.)
After setting the sensitivity level from the Control Panel, please press
and hold the button on the fall sensor for 8 seconds to receive the
sensitivity level data from the Control Panel. (Refer to the Fall
Sensor FS-3 user manual to complete sensitivity setting.)
Speaker Volume Level
18