Smoke and Carbon Monoxide Detector   
(SDCO-1-RhTH-ZW-SC-AC/SDCO-1-RhTH-ZW-SC-OTA-AC) 
Introduction 

SDCO-1-RhTH-ZW-SC-AC/SDCO-1-RhTH-ZW-SC-OTA-AC  is  a  Z-Wave  Smoke  and  Carbon  Monoxide  Detector  with 
temperature, humidity, and heat detection, as well as voice prompts and allows 

access to the “S2 Unauthenticated” class. It is 

capable of sending wireless signals to the Z-Wave gateway/control panel upon detection of smoke particles or Carbon Monoxide. 
The  device  is  also  serially  connected  with  other  sensors  in  the  Z-Wave  gateway  to  serve  as  an  extra  siren. When  any  other 
sensor in the Z-Wave network is activated and sends an alarm signal, the Smoke Detector will also raise alarm with its built-in 
buzzer as a siren to help sound warning (for serial connection models). 

The SDCO-1 is designed to be mounted on ceiling or top of stairwells when smoke would concentrate to raise alarm timely and 
protect your home from fire hazards. 

The  SDCO  is  a  Z-Wave  enabled  device  and  is  fully  compatible  with  any  Z-Wave  enabled  network.  Z-Wave  is  a  wireless 
communication protocol that uses a low-power RF radio.   

Parts Identification 

 

 

1.  Speaker 

2.  Button 

  Press the button once to send an alarm test, temperature and humidity signals / test Smoke and Carbon Monoxide Detector. 

  Press the button once during alarm to silence the alarm. 

  Press the button 3 times within 1.5 seconds to send an inclusion code. 

  Press and hold the button for 10 seconds. Release the button when you hear 2 beeps to enter smoke calibration and CO self-diagnosis   

.

process.   

  Press and hold the button for 20 seconds. Release the button when you hear 3 beeps to perform factory reset. 

  Press the button twice before inserting new batteries. 

3.  LED Indicator   

Red LED 

  Turns ON briefly: Transmitting signal. 

  Quick flash: Alarming. 

  Flashes every second: In Alarm Silence Mode. 

  Flashes every 2 seconds: Under warmup and calibration process.   

Amber LED 

  Flash every second: Device power on/Calibration failed. 

  Flashes every 5 seconds: Auto-calibration/self-diagnostic has failed. 

  Flashes every 45 seconds: Low battery condition 

Both Red and Amber LED (Orange when looking from the outside) 

  Turns ON: Temperature/ Humidity sensor failed. 

  Flashes every 4 seconds: Battery exhausted. 

4.  Buzzer 

5.  Mounting Holes (for Hooks) 

The Hooks of the Mounting Bracket can hook into this Mounting Hole. 

6.  Mounting Bracket 

7.  Internal Tamper 

8.  Battery Compartment Cover 

9.  Battery Switch 

10. Pre Punched Hole for Wiring   

Содержание SDCO-1-RhTH-ZW-SC-AC

Страница 1: ...ication 1 Speaker 2 Button Press the button once to send an alarm test temperature and humidity signals test Smoke and Carbon Monoxide Detector Press the button once during alarm to silence the alarm...

Страница 2: ...Step 4 Push the lever back down The transparent housing allows you to check if the wire is connected properly Make sure the wire is properly connected before you proceed Figure 1 Figure 2 Step 5 Repea...

Страница 3: ...ency Carbon Monoxide in location name Played when an alarm is triggered 9 Emergency Smoke in location name Played when an alarm is triggered 10 Evacuate Played when an alarm is triggered 11 Basement P...

Страница 4: ...CO concentration is detected according to time length in the following table compliant with UL 2034 standard CO concentration level Time taken before alarming 30 3 ppm N A 70 5 ppm N A 70 5 ppm 60 240...

Страница 5: ...refer to Command Class Data Format section for details Factory Reset Only use factory reset when network Control Panel Gateway is missing or inoperable Press and hold the button of the SDCO for 20 sec...

Страница 6: ...p 10 Wipe away dust thoroughly or it can make the sensor dirty and prevent it from operating properly in case of an emergency Step 11 Remove the battery compartment cover and attach the cable to the P...

Страница 7: ...00 00 00 FF 08 02 00 AC Restore 00 00 00 FF 08 03 00 Battery COMMAND_CLASS_BATTERY BATTERY_REPORT 0x64 100 Battery Full 0x5A 90 Battery 0x50 80 Battery 0x46 70 Battery 0x3C 60 Battery 0x32 50 Battery...

Страница 8: ...Please refer to Alarm Silence section for details The SDCO will send an alarm silence report in the following three conditions When the temperature has dropped below alarm threshold the SDCO will sen...

Отзывы: