background image

59

Main Menu Buttons  -  

Settings

Installation Settings

Fan Off Delay

(0s)

Runs the fan for a short time after Cooling or electric strip heat 

turns off to increase system efficiency. (0 - 120 Secs.)

 

(Continued)

 

 

Sensor Settings

Control Source

(thermostat )

When a remote sensor is connected to the thermostat, the user may

choose which sensor source is used to measure room temperature. 

 

Wireless Sensors

Add New Sensor

Remove Sensor

•  Thermostat sensor only 
•  Wired sensor only
•  Average all wireless sensors
•  Average wired/thermostat
•  Average wireless/thermostat
•  Average all available sensors

You may pair multiple Wi-Fi remote sensors to the thermostat to 

be used for temperature monitor or control.  The sensors MUST be 

on the same Wi-Fi network as the thermostat. Skyport connectivity 

is not required. Start the pairing process by pressing the LINK 

button on the Wi-Fi sensor.  This will cause it to send a message to 

the Wi-Fi router that will in turn broadcast that message. Any 

thermostat on the network should hear that broadcast and store 

information about the sensor. Use this section to Add New Sensor 

for use by the thermostat (pair) or Remove sensor to quit listening 

to a sensor (unpair). Multiple thermostats can pair to the same 

sensor (handy for outdoor sensor use) or pair to a group of 

sensors (average multiple sensors in a large space served by 

multiple units).

Содержание AVB32V03R

Страница 1: ...HIGH RESOLUTION TOUCH SCREEN Digital Thermostat with Humidity Control Up to 3 heat 2 cool AVB32V03R CM500 series Residential Owner s Manual Installation Instructions with Wi Fi...

Страница 2: ...dealer or an experienced radio orTV technician for help Notice Only peripherals complying with FCC limits may be attached to this equipment Operation with noncompliant peripherals or peripherals not...

Страница 3: ...est conforme avec Industrie Canada exempts de licence standard RSS s Son fonctionnement est soumis aux deux conditions suivantes 1 ce dispositif ne doit pas causer d interf rences et 2 ce dispositif...

Страница 4: ...uto Mode Heat Setpoint The coolest temperature that the space should drop to before heating is turned on without regard to deadband Icon The word or symbol that appears on the thermostat display Mode...

Страница 5: ...ing the Time Date 7 Setting the Time 8 Setting the Date 9 Daylight Savings Setup 9 Connecting to Wi Fi 10 WiFi Set up Create a Skyport Account 12 MAIN MENU BUTTONS SCHEDULE 13 View My Schedule 14 Edit...

Страница 6: ...ntenance 24 PREFERENCES 25 User Interface Themes 26 Custom Wallpaper 26 Heat Cool Indicator 26 Sound Options 26 HUMIDITY 27 Humidification Settings 28 Dehumidification Settings 28 VACATION AWAY 29 Cle...

Страница 7: ...ALLATION SETTINGS 56 Heat Cool Stages 56 Heat Cool Stages 56 Compressor Stages 56 Aux Heat Stages 56 Timers Deadbands 56 D H Output Settings 58 Fan Off Delay 59 Sensor Settings 59 Control Source 59 Wi...

Страница 8: ...SKYPORT 67 Account 67 EMERGENCY HEAT 68 INSTALLATION INSTRUCTIONS 69 Remove Replace the Old Thermostat 69 Wire Connections 70 The Touch Screen Thermostat Backplate 71 Explanation Of the Thermostat Dip...

Страница 9: ...lay Date Time Fan Button Home Away Button OutdoorTemperature Cooler Button Warmer Button SD Card Slot Menu Button Mode Buttons If optional accessory is used or connected to Skyport Indoor Humidity Rea...

Страница 10: ...ontents of your Dashboard may vary The Dropdown Dashboard displays temperature humidity and other readings It will also show the high and low readings of the day There is also a button to exit the das...

Страница 11: ...graphs Weather This screen only appears when the thermostat is communi cating with Skyport Current temperature humidity and a 3 day forecast is shown based on the address details entered for the Skypo...

Страница 12: ...s can be founds at menu alerts Thermostat Information This section contains four different screens that allow easy viewing of the thermostat model number firmware revision wifi and Skyport status as w...

Страница 13: ...ects should never be used on your thermostat these may damage your touchscreen Only use your finger tip to press the touchscreen buttons Use a soft damp cloth to clean the screen DO NOT USE ABRASIVE C...

Страница 14: ...rned off AUTO CHANGEOVER MODE Pressing theWARMER or COOLER buttons in Auto mode will adjust both the heat and cool setpoints simultaneously To adjust heat and cool setpoints individually choose HEAT m...

Страница 15: ...OFF Start Schedule Starts On Day Month Stop Schedule Ends On Day Month 2nd Sun March 1st Sun November NOTE When the thermostat is connected to a Skyport account theTime Date are automatically synchro...

Страница 16: ...rrent Time 12 00 AM hr hr min min Press and to set the current time Press when finished Press then to scroll down Press Use AM PM ON Use AM PM OFF For 12 hour AM PM clock For 24 hour clock Choose Pres...

Страница 17: ...5 14 13 12 11 18 19 20 21 22 23 24 31 30 29 28 27 26 25 1 2 3 4 5 6 7 Press Press Daylight Savings Time OFF Daylight Savings Time ON Start Schedule Starts On Day Month Stop Schedule 2nd Sun March Ends...

Страница 18: ...t the access point you wish to connect to from the list Enter the password for the Wi Fi Access Point and press NEXT Select automatic setup and press NEXT When finished a dialog box will appear confir...

Страница 19: ...tic setup and press NEXT When finished a dialog box will appear confirming the successful connection to the local Wi Fi Access Point Select OK then the Wi Fi status page will appear Upon closing of th...

Страница 20: ...l Wi Fi Access Point but not yet joined to a Skyport account you may join the thermostat to an account by doing the following Select MENU from the thermostat s home screen Scroll down Select Skyport S...

Страница 21: ...13 Main Menu Buttons Schedule Schedule View My Schedule Edit My Schedule...

Страница 22: ...t The start time for each time period is adjustable The stop time for each time period is the start time for the next period Press a day of the week to view its settings This may be repeated for each...

Страница 23: ...nd select aTime Period Morning Day Evening or Night to edit Edit My Schedule Continued Adjust Mode StartTime and Heat and Cool Setpoints to desired settings Save Edit Next TheTime Period may also be E...

Страница 24: ...16 Main Menu Buttons Smart Fan Who To Call For Service View Runtime Graphs Smart Fan OFF Smart Fan Min Runtime Smart Fan Who To Call For Service View Runtime Graphs Start Stop Times Days To Run Fan...

Страница 25: ...day Press to turn fan schedule on or off Set the minimum number of minutes the fan will run from the top of each hour Set runtime to 60 minutes to be on continuously from StartTime to Stop time 5 60 m...

Страница 26: ...raphs Screensaver OFF Screensaver Setup Screensaver Turn On Delay Change Image After Show Clock OFF Screensaver Type Screensaver Home Screen Info OFF View Runtime Graphs Screensaver Preview Slideshow...

Страница 27: ...ore returning to the Home Screen After the preview press anywhere on the screen to return to the sub menu Screensaver Screensaver Setup The Screensaver allows you to create custom slideshows Screensav...

Страница 28: ...eset Air Filter Alert Reset UV Lamp Alert Alerts Set Edit Reminders Service Information UV Lamp Reminder OFF Max UV Lamp Runtime 300 hrs Set Max Filter Days 0 days 360 days Service Call Reminder OFF D...

Страница 29: ...vice alert runtimes and turn reminders on or off View and reset current service alerts here Alerts will appear on the bottom bar of the Home Screen Press to view and reset current alerts Dealer s Logo...

Страница 30: ...22 Main Menu Buttons Display Screen Cleaning Touch Calibration Active Brightness Night Dimmer Display Maintenance Auto Night Dimmer OFF Set Idle Brightness Set Dimmer Schedule Idle Brightness...

Страница 31: ...splay is active for 3 minutes after last touch it then goes Idle You may dim the brightness of the screen at night The screen can be set to dim automatically at night Dimming the display can prolong t...

Страница 32: ...ean and calibrate the touch screen Screen Cleaning Mode disables the touch feature for 15 seconds so the screen may be cleaned without altering any settings Under normal circumstances the touchscreen...

Страница 33: ...tons Preferences User Interface Themes Custom Wallpaper Heat Cool Indicator OFF Taskbar red white OFF Room Temp red blue OFF Mode Status red blue OFF Preferences Heat Cool Indicator Sound Options Beep...

Страница 34: ...ound will change to an evening scene At 7am it will return to a daytime scene You may choose your own background image by selecting a photo that you have uploaded from an SD memory card Sound Options...

Страница 35: ...ty Humidification Settings Humidify setpoint 0 Dehumidification Settings Humidify with heat OFF Run fan w humidity demand OFF Dehumidity setpoint 99 0 Run A C to dehumidify OFF Maximum Overcool Reheat...

Страница 36: ...Dehumidification 0 20 degrees F Dehumidify setpoint 99 Adjust Dehumidify setpoint 25 99 Run A C to dehumidify OFF When this step is ON the A C system will be used for Dehumidification When this step...

Страница 37: ...n Menu Buttons Vacation Away Clear Vacation Schedule Set Vacation Schedule Start Date Start Time Return Date Return Time Vacation Away Mode Heat Setpoint Cool Setpoint Settings while away OFF Auto Hea...

Страница 38: ...out changing the regular schedule Pressing the HOME button will return the thermostat to normal comfort settings Vacation Away Removes the stored vacation schedule Start Date Tue Sep 07 2010 Start Tim...

Страница 39: ...n Date Tue Sep 21 2010 Return Time 3 00 PM Mode Heat Setpoint Cool Setpoint 85 50 Continued Select the day Vacation Mode will end Then press Select the time Vacation Mode will end Then press Select th...

Страница 40: ...Auto Screenlock Setpoint Limits Security Auto Screenlock OFF Set Passcode Lock After Setpoint Limits OFF Minimum Cool Setpoint Maximum Heat Setpoint Allow fan mode changes NO Allow setpoint changes N...

Страница 41: ...must be set before Auto Screenlock can be turned on Press UNLOCK then enter passcode to access thermostat settings Set the time the screen will automatically lock after the last button press When the...

Страница 42: ...34 Main Menu Buttons Information View Runtime Graphs Information Last 7 Days Cooling Last 7 Days Heating Who To Call For Service Delete Runtime Data...

Страница 43: ...be displayed here Dealer s Logo here View Runtime Graphs Last 7 Days Cooling Last 7 Days Heating Track your system s runtime energy usage Press the information icon to learn more about each graph Pres...

Страница 44: ...Fahrenheit Celsius Heat Cool Stages Compressor Stages Aux Heat Stages English Spanish Espanol French Francais Heat Cool Stages Continued next page Import Settings from SD Card Export Settings to SD C...

Страница 45: ...dband Setpoint 1st Stage Deadband 2nd Stage Deadband 2nd Stage Timer 2nd Stage Turnoff Point 3rd Stage Deadband Deadband Setpoint 3rd Stage Deadband 3rd Stage Timer 3rd Stage Turnoff Point Installatio...

Страница 46: ...ontrol Source Thermostat Sensor Only Wired Sensor Only Average All Wireless Sensors Average Wired Thermostat Average Wireless Thermostat Average all available Sensors Wireless Sensors Add New Sensor R...

Страница 47: ...Settings Dealer Information Dealer Name Contact Name Dealer Phone Dealer Email Dealer Website Factory Defaults Restart Thermostat Installation Settings Settings Test Outputs Upgrade Firmware Delete Cu...

Страница 48: ...ral Setup Units F Fahrenheit F Celsius C SD Card Import and export files to and from the thermostat See the Touch Screen Desktop App instructions for further details Venstar com thermostats colortouch...

Страница 49: ...time to adjust When used with a heat pump electric strip heat will be disabled while Smart Recovery is active Language en English Spanish Espa ol French Fran ais Menu Button Press for Cooling Press f...

Страница 50: ...the comfort settings of the thermostat in order to reduce energy usage on demand This is known as Automated Demand Response or ADR for short You must register to participate in a utility sponsored pr...

Страница 51: ...e thermostat is configured to respond to the energy provider s signals It also sets operational parameters for the thermostat The left column of the ADR configuration page allows or prevents access by...

Страница 52: ...tpoints for ADR events are adjusted here The Static Settings are applied when the utility sends a signal to allow the occupant to enforce their own discrete temperature settings during an ADR event Th...

Страница 53: ...45 Selecting the Overview tab of the ADR page will cause a summary of ADR events to be displayed Main Menu Buttons Settings...

Страница 54: ...at the Skyport Cloud Services account From the thermostat Home Screen press the Menu button then select Settings From the above screen the Automated Demand Response button is pressed By selecting ADR...

Страница 55: ...e the set threshold In the above example if the price threshold is exceeded the thermostat will invoke the Offset Setpoints configured for an ADR event until the event is over Please note that the Thr...

Страница 56: ...48 Main Menu Buttons Settings The user may limit the maximum Cooling Setpoint...

Страница 57: ...49 Main Menu Buttons Settings The user may limit the minimum Heating Setpoint...

Страница 58: ...50 Main Menu Buttons Settings 2 The user may adjust the ADR Cooling static Setpoint...

Страница 59: ...51 2 Main Menu Buttons Settings The user may adjust the ADR Heating static Setpoint...

Страница 60: ...52 The user may adjust the ADR Cool offset During an ADR event the cooling setpoint will be adjusted by the amount of degrees configured in this step Main Menu Buttons Settings 2...

Страница 61: ...53 2 Main Menu Buttons Settings The user may adjust the ADR Heat offset During an ADR event the heating setpoint will be adjusted by the amount of degrees configured in this step...

Страница 62: ...ending and hasn t started yet there will be a yellow leaf on the top bar This will be accompanied by associated text as shown below During an ADR event there will be a green leaf on the top bar This w...

Страница 63: ...ssed during an active ADR event then the user is presented with this opt out screen If a pricing triggered ADR event is enabled there will be a green leaf on the top bar along with the actual cost of...

Страница 64: ...to 2 Stages Cooling and 4 stages Heating Compressor Stages 1h1c Up to 2 compressors Aux Heat Stages 1h1c 0 or 1 stage of Aux Heating Min Heat Cool Difference 2 The minimum gap between Heat and Cool s...

Страница 65: ...e deadband is set to 2 degrees the room temperature will need to drop to 66 degrees before the heat turns on 3rd Stage Deadband 1st Stage Deadband 2 1 6 deg F 2nd Stage Deadband 2nd Stage Deadband 2 2...

Страница 66: ...inued D H output usage dehum IMPORTANT D H Output Usage must be set for Hum or Dehum before any settings will take effect in the Humidity Main Menu D H output polarity n o The D H Output polarity may...

Страница 67: ...u may pair multiple Wi Fi remote sensors to the thermostat to be used for temperature monitor or control The sensors MUST be on the same Wi Fi network as the thermostat Skyport connectivity is not req...

Страница 68: ...ensor Humidity The first four options allow you to connect a 10K thermistor to the SENSOR terminals to be used to monitor a temperature outdoor supply return or control to a temperature remote The las...

Страница 69: ...in the thermostat SD Card reader and contain the valid firmware If an error message appears confirm with the ColorTouch Desktop APP that firmware is up to date or simply try reinserting the SD card De...

Страница 70: ...62 Main Menu Buttons Wi Fi Wi Fi Setup Choose Network Password Entry Local API OFF API Protocol Wi Fi Status Wi Fi Enabled Local API Option HTTP HTTPS...

Страница 71: ...to be turned off or on Wi Fi Setup Choose your network from the list and enter the network password If your network does not appear in the list hit the refresh button Network Name 1 Network Name 2 Ne...

Страница 72: ...referred then select API Protocol This is the default with the local API OFF Upon pressing API Protocol the following screen will appear Then select HTTPS and press BACK Local API OFF Local API OFF AP...

Страница 73: ...asic Auth User API Protocol http API Protocol http API Protocol https Basic Auth Password Main Menu Buttons Wi Fi Q W E R T Y U I O 64 remaining A S D F G H J K L Shift BACK DONE Basic Auth User 123 S...

Страница 74: ...below and press DONE to save Q W E R T Y U I O 64 remaining A S D F G H J K L Shift BACK DONE Basic Auth Password 123 SPACE Z X C V B N M Del P X Basic Auth Password The last step is to turn the Local...

Страница 75: ...ort Account Skyport Skyport Services ON Weather Updates ON Pressing this button will let you know if you are paired with a Skyport account If not then you may follow prompt and instructions to create...

Страница 76: ...cy Heat operation the thermostat will turn on the fan and auxiliary stages of heat when there is a demand for heat The 1st stage of heating and all stages of cooling will be unavailable To exit Emerge...

Страница 77: ...wer to the Heating Air Conditioning system at the main fuse panel Most residential systems have a separate breaker for disconnecting power to the furnace Remove the cover of the old thermostat If it d...

Страница 78: ...ifier D H note 1 H on CLM products ClimaDry D H note 2 dehumidifier dehumidifier D H note 2 AL1 AL2 fault condensate sensor note 3 R Rh M Vr A power power R C common common C Wire from the old thermos...

Страница 79: ...nted junction box would be needed for that type of installation D H W O SENSOR WIRE TERMINAL FUNCTIONS The table on page 70 shows how to wire to either a heatpump or conventional system and explains t...

Страница 80: ...n GAS EL or HP is set for GAS EL This switch GAS or ELEC controls how the thermostat will control the Fan G terminal in heating mode When GAS is chosen the thermostat will not energize the Fan G termi...

Страница 81: ...lation Instructions Sample Wiring Diagrams Single Stage Heat Pump with AUX Heat D H W O SENSOR Y W O G R C AL1 AL2 A Note Do not clip jumper JW1 on CXM board Dip Switch Settings 1 GAS O GAS EL ELEC B...

Страница 82: ...stages via MENU Settings Installation Settings Heat Cool Stages Compressor Stages Note 2 If using the integral con densate overflow sensing in the heatpump an overflow condition generates a FAULT sig...

Страница 83: ...SEN or ACC DSEN 1 GAS O GAS EL ELEC B HP ON 2 3 Notes 1 Connect the two wires from the sensor to the two SENSOR terminals To enable the function set MENU Settings Installation Settings AUX IN use to U...

Страница 84: ...y open Condensate Overflow switch between the two SENSOR terminals To enable the function set MENU Settings Installation Settings Sensor Settings AUX IN use to Condensate Overflow When triggered cooli...

Страница 85: ...W D H Humidification System DEHUM HUM Dehumidification Terminal on Equipment SENSOR SENSOR Sample Wiring Diagrams Use 16 24 gauge thermostat wire Use 16 24 gauge thermostat wire D H Output Usage must...

Страница 86: ...t point limit See Setpoint Limits page 33 SYMPTOM The heating does not attempt to turn on CAUSE The heating setpoint is set too low REMEDY Raise the heating setpoint or raise the heating set point lim...

Страница 87: ...WHATSOEVER ALL WORK UNDERTHETERMS OFTHIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS ALL REPLACEMENT PARTS WHETHER NEW OR REMANUFACTURED ASSUME ASTHEIR WARRANTY PERIOD ONLYTHE REMAININGTIM...

Страница 88: ...P N 88 1358 Rev 1 03 27 20 Patents Issued Pending...

Отзывы: