PORTABLE AIR CONDITIONER
Instruction Manual for PAC20A
PAC20A
19,500btu Portable Air Conditioner
Please read this manual carefully prior to operating the product.
Please keep ALL packaging for duration of Warranty Period
Страница 1: ...AIR CONDITIONER Instruction Manual for PAC20A PAC20A 19 500btu Portable Air Conditioner Please read this manual carefully prior to operating the product Please keep ALL packaging for duration of Warranty Period ...
Страница 2: ...drainage piping is connected properly 7 Do not start or stop the unit by inserting or pulling out the power plug 8 Do not operate with wet hands 9 Close supervision is necessary when the unit is used near children The unit in not intended for use by children 10 Do not insert anything into the air outlet Do not obstruct air inlet or outlet grills 11 Do not expose skin or eyes directly to cool air f...
Страница 3: ...t 29 Keep Filters Clean 30 Keep Curtains Closed During the sunniest part of the day 31 Do not use extension leads 32 Only use in the up right position 33 For Indoor Use Only General Information Recycling This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste di...
Страница 4: ..._____________ Invoice Number _______________________________________________________ WARRANTY This product comes with a 12month warranty from date of purchase as indicated on original sales receipt Please note that it is a warranty condition that ALL of the original packaging is kept for the duration of the warranty period the main box can be folded flat for storage If you need to make a warranty ...
Страница 5: ...MARK 1 Measuring condition for above is as per EN 14511 Cooling DB 35 C WB 24 C DB temperature of dry bulb room temperature WB temperature of wet bulb relative humidity 2 Test condition for data in our rating label is as per safety regulation EN 60335 2 40 3 Current Fuse F2L250V or T2L250V This equipment contains fluorinated greenhouse gas R 410a The fluorinated greenhouse gas is contained in a he...
Страница 6: ...essories 12 Exhaust hose 13 Remote control 14 Drain tube for continuous drainage 15 Round Adapter for connecting the unit and the exhaust pipe 16 Flat Adaptor for connecting the exhaust pipe and the window spacer 17 Window spacer for filling the open window space 18 Window spacer for filling the open window space 19 Window spacer for filling the open window space and with hole for connection to ex...
Страница 7: ...d securely This technique may also be used for sash windows Note Take care to maintain protection against intruders Use only the hose provided and clip exhaust hose and unit adaptor to the back of the air conditioner Avoid kinks and bends in the exhaust hose as this will cause expelled moist air to build up causing the unit to overheat and shut down The hose may be extended from 300mm to 1500mm bu...
Страница 8: ...and animal odor Please note the carbon filter is not washable its life span is variable and depends on the ambient conditions where the unit is used The filter should be checked periodically and replaced if necessary normally it s 6 months below is the installation of the active carbon filter along with this unit 1 Separate the filter frame the unit 2 Take out the carbon filter from its bag 3 Appl...
Страница 9: ... indicator k Sleep mode indicator BEFORE USE Check that the Exhaust Hose has been mounted properly see Installation section If the exhaust Hose is not correctly used hot air will blow back into the room you are trying cool Check that the drain plug at the bottom rear of the unit is securely plugged in to prevent water leaks see page 13 Water Drainage Check that the local mains power matches that s...
Страница 10: ...r ventilate depending on ambient temperature and setpoint adjustment The unit is preset as follows 1 If ambient temperature is 23 C the unit will be in automatic cooling mode Default setting 24 C During this operation the indicator for AUTO and COOL mode light up 2 If the ambient temperature is 24 C but 20 C the unit will work in ventilation mode During this operation the indicator for AUTO and FA...
Страница 11: ...ss Temperature up or Temperature down button to regulate the temperature you desired 2 The display window will show the temperature you set as you press Temperature up or Temperature down button Otherwise it will always show the ambient temperature 3 The pre setting temperature of this machine is 24o C for cooling Setting ventilation speed Press SPEED button to choose the ventilation speed you nee...
Страница 12: ...tting temperature and ventilation speed will return to the pre selected one 3 The unit will shut down automatically after the SLEEP function running for 12 hours 4 Please note the sleep function is not available while the machine is working in ventilation dehumidification or auto mode Only available in Cooling mode 5 When the machine is in Sleep function the Fan Speed would turn to be LOW speed De...
Страница 13: ...ld NOT be over 3L otherwise the water full indicator will light in red and the unit will stop working 2 In case the water full indicator is in red please drain the water from the drain point at the back side of the unit until the red light goes out The unit should work again now IMPORTANT 1 To prolong the compressor s life after switch off of the unit please wait for 3 minutes at least before re s...
Страница 14: ...water tray for example underneath the drain hole 3 Remove the drain knob rubber plug from the drain hole and allow the water to drain out 4 When the container is almost full replace the rubber plug in the drain hole and empty the water tray 5 Repeat until the unit is emptied 6 Replace the rubber plug and tighten the drain knob firmly 7 Switch on the unit the full water or compressor operating indi...
Страница 15: ...lease note 1 The drain must be at a lower level than the drain hole on the unit 2 Flashing Water Full indicator will not function in this mode of drainage 3 If you want to extend the water tube you can connect it with another tube OD 18mm The extended tube is NOT supplied along with the unit Originally supplied drain tube Extended drain tube outer diameter 18mm Originally supplied drain tube ...
Страница 16: ...End of season storage Drain any water in the unit before completely operating the unit on ventilation only mode for a few hours to thoroughly dry the inside Clean or change the filter Unplug and store the power cord on the cord hanger Replace in the original carton or cover for storage SELF DIAGNOSIS This machine is equipped with self diagnosis function If something is wrong in the machine the LED...
Страница 17: ... of heat The machine seems to do nothing Is the filter dusty contaminated Is the air intake or output blocked up Is the room temperature below your selected temperature Too noisy Is the machine positioned unevenly so as to create vibration Is the floor underneath the machine uneven The compressor doesn t run If so it is possible the overheat protection of the compressor is on Just wait for the tem...