TEST REPORT
Page 27 of 33
Issue Date: 2
nd
March 2010.
SGS Serial Number:
AUT130731/1/GH/10.
Test Report
Date: 01-13-2010
Time: 10:53:07
AUT: 130731/1.
Company Name :
Directed Electronics Inc.
Equipment Tested :
Viper Responder 350.
Serial Number :
691111266525.
Test Equipment used :
TESEQ Generators
Test Procedure Used :
ISO 7637 - 2.
Test Number 1
Test Name
12vp4.
Test Type
Pulse 4
Sequence Repetition
Count 1
Test Status
PASS. A.
Segment Number # 1 RAMP
Parameter
Mode
Initial Value
Final Value
Amplitude
Static
12 Vpp
- - -
Parameter
Value
Segment Duration
100 ms
Segment Number # 2 RAMP
Parameter
Mode
Initial Value
Final Value
Amplitude
Linear
12 Vpp
6 Vpp
Parameter
Value
Segment Duration
5 ms
Segment Number # 3 RAMP
Parameter
Mode
Initial Value
Final Value
Amplitude
Static
6 Vpp
- - -
Parameter
Value
Segment Duration
15 ms
Segment Number # 4 RAMP
Parameter
Mode
Initial Value
Final Value
Amplitude
Linear
6 Vpp
8 Vpp
Parameter
Value
U
K
A
pproval Auth
or
it
y
24-Mar-10
Содержание 350HV
Страница 42: ...G426V_2008_08a qxd 8 13 2008 10 22 AM Page 34 U K A pproval Auth o r i t y 24 Mar 10...
Страница 85: ...38 G919730P_01 07 qxd 1 12 07 3 39 PM Page 38 U K A pproval Auth o r i t y 24 Mar 10...
Страница 171: ...2007 directed electronics 53 N919730P_01 07 qxd 1 12 07 3 41 PM Page 53 U K A pproval Auth o r i t y 24 Mar 10...
Страница 176: ...www directed com 58 N919730P_01 07 qxd 1 12 07 3 41 PM Page 58 U K A pproval Auth o r i t y 24 Mar 10...
Страница 179: ...Model 460HP Owner s Guide G426P_2008 08 qxd 8 14 2008 10 57 AM Page 1 U K A pproval Auth o r i t y 24 Mar 10...