background image

NOTES

:

Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers.

SECT.

IIA

PAGE 

12

0108

W1

W2

D

RC

S

CS

AV

G

E1

E2

W1

W2

D

RC

S

CS

AV

G

E1

E2

W1

W2

D

RC

S

CS

AV

G

E1

E2

The "Advanced Closed System" offers the following advantages:

II

Saves energy

II

Automatic moisture level adjustment

II

Low heat and steam emission to the kitchen

II

Automatically regulated steam injection 

II

Enables immediate change into the steam mode 

II

"Crisp & Tasty" demoisturizing function

Model: 

OEB-12.20

Pan Capacity

[Unit (trolley) has 12 slide rails at 2.64" (67mm) apart]

12 

(20" x 26") full size wire racks

12

(18" x 26") full size sheet pans - 

on wire racks

24

(13" x 18") half size sheet pans - 

on wire racks

24

(12" x 20" x 2 1/2") steam table pans

24

(12" x 20" x 1") steam table pans

24

(12" x 20") frying baskets - (

no wire racks needed

)

For Banquet Operations:

Optional Plate Rack holds 74 plates

Unit Dimensions:

Width - 53.83", Depth - 44.34", Height - 57.73"

Shipping Dimensions:

Width - 60", Depth - 50", Height - 66"

(including packaging)

Shipping Weight:

717 Lbs (including trolley)

Required Clearances:

Rear - 2", Left Side - 4", Right Side - 2 1/2"

• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located

next to the unit.

• Allow for sufficient clearance on left side for service access (contact the

factory service department for recommendations).

• Installation must comply with all local fire and health codes.

Agency Approvals:

UL, UL - Sanitation (NSF Standards)

Electrical Requirements:

208/3/60

240/3/60

440/3/60

480/3/60

Total Connected Load: 

26.3 KW

34.9 KW

29.4 KW

34.9 KW

Hot Air: 

25.8 KW

34.3 KW

28.8 KW

34.3 KW

Steam Generator:

23.1 KW

30.7 KW

25.8 KW

30.7 KW

Amps per Phase:

77.8

88.8

41.4

44.9

Do not connect to a G.F.I. outlet

Water Connections:

Cold Water (drinking water quality)

Flow Pressure:

30 - 60 PSI

Water Inlets:

3/4" GHT-F (Female Garden Hose Connection)

Treated Water for Steam Generator

Untreated Water for Condenser and Hand Shower

Drain Connection:

2" Tube

Venting:

Exhaust Hood required

Air Vent

*Connection for Cleaning Solution

*Connection for Rinse Cycle

Low Pressure Safety Valve

*

Available as an option

W1

W2

D

RC

S

CS

AV

G

E1

E2

W1

W2

D

RC

S

CS

AV

G

E1

E2

W1

W2

D

RC

S

CS

AV

G

E1

E2

W1

W2

D

RC

S

CS

AV

G

E1

E2

W1

W2

D

RC

S

CS

AV

G

E1

E2

48.51"

2.52"

1.58"

4

6

.7

0

"

9.06"

2.80"

5

6

.1

5

"

4

1

.5

4

"

2

.8

0

"

12.68"

2.80"

8.55"

2

.6

0

"

3

.3

9

"

4

.8

1

"

7

.4

8

"  

1

3

.0

8

"

3.08"

1

4

.2

6

"

10.87"

42.29"

3.15"

6.50"

1

0

.4

0

"

2

5

.7

9

"

1

8

.9

0

"

2

.9

6

"

2

7

.2

9

"

1

.1

9

"

29.57"

5.48"

3.00"

4.97"

S

AV

E1

E2

RC

CS

W1

W2

D

G

FRONT VIEW

TOP VIEW

BOTTOM VIEW

31.50"

48.51"

2.52"

1.58"

4

6

.7

0

"

9.06"

2.80"

5

6

.1

5

"

4

1

.5

4

"

2

.8

0

"

12.68"

2.80"

8.55"

3

.3

9

"

4

.8

1

"

7

.4

8

"  

1

3

.0

8

"

3.08"

1

4

.2

6

"

10.87"

42.29"

3.15"

6.50"

1

0

.4

0

"

2

5

.7

9

"

1

8

.9

0

"

2

.9

6

"

2

7

.2

9

"

1

.1

9

"

29.57"

5.48"

3.00"

4.97"

S

AV

E1

RC

CS

W1

W2

D

G

FRONT VIEW

TOP VIEW

BOTTOM VIEW

31.50"

48.51"

2.52"

1.58"

4

6

.7

0

"

9.06"

2.80"

5

6

.1

5

"

4

1

.5

4

"

2

.8

0

"

12.68"

2.80"

3

.3

9

"

1

3

.0

8

"

3.08"

1

4

.2

6

"

10.87"

42.29"

3.15"

6.50"

2

5

.7

9

"

1

8

.9

0

"

2

.9

6

"

2

7

.2

9

"

1

.1

9

"

29.57"

5.48"

3.00"

4.97"

S

AV

RC

CS

W1

W2

D

FRONT VIEW

TOP VIEW

BOTTOM VIEW

31.50"

A = Water hook up soft water G"
B = Water hook up cold water G"
C = drainage hook up DN50
D = power hook up
E = Potential equaliser
F = Final rinse hook up
G = Cleaner hook up
H = Air vent pipe
I  = Low pressure safety

OEB 12.20

A = Water hook up soft water G"
B = Water hook up cold water G"
C = drainage hook up DN50
D = power hook up
E = Potential equaliser
F = Final rinse hook up
G = Cleaner hook up
H = Air vent pipe
I  = Low pressure safety

OES 12.20

OGB 12.20

A Water hook up soft water G"
B Water hook up cold water G"
C Drainage hook up DN50
D Power hook up
E Potential equaliser
F Final rinse hook up
G Cleaner hook up
H Air vent piper 
I Low pressure safety

J Gas hook up R"
K Exhaust pipe gas (Hot air heating)
L Exhaust pipe gas (Steam generator)

OGS 12.20

A = Water hook up soft water G"
B = Water hook up cold water G"
C = Drainage hook up DN50
D = Power hook up 
E = Potential equaliser
F = Final rinse hook up
G = Cleaner hook up
H = Air vent pipe
I  = Low pressure safety

J = Gas hook up R"
K = Exhaust pipe gas 