Statement of Responsibilities

This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service
Representatives who are familiar with both the safety procedures, and equipment they service.

Cleveland Range, LLC assumes no liability for any death, injury, equipment damage, or property damage
resulting from use of, improper use of, or failure to use the information contained in this document. 

Cleveland Range, LLC has made every effort to provide accurate information in this document, but
cannot guarantee that this document does not contain unintentional errors and omissions.

The information in this document may be subject to technical and technological changes, revisions, or
updates.

Cleveland Range, LLC assumes no liability or responsibility regarding errata, changes, revisions, or
updates.

Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to follow industry
standard safety procedures, including, but not limited to, OSHA regulations, and disconnect / lock out /
tag out procedures for all utilities including steam, and disconnect / lock out / tag out procedures for gas,
electric, and steam powered equipment and / or appliances

All utilities (gas, electric, water and steam) should be turned OFF to the equipment and locked out of
operation according to OSHA approved practices during any servicing of Cleveland Range equipment

Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to maintain up-to-date
knowledge, skills, materials and equipment.

Содержание 24CSM Series

Страница 1: ...technical and technological changes revisions or updates Cleveland Range LLC assumes no liability or responsibility regarding errata changes revisions or updates Qualified Cleveland Range LLC Authoriz...

Страница 2: ...Cleveland Range LLC 1333 East 179th St Cleveland Ohio U S A 44110 Ph 1 216 481 4900 Fx 1 216 481 3782 Visit our Web Site at www clevelandrange com...

Страница 3: ...ther the high pressure switch or the low water cut off float switch opens the latch circuit opens x When the contacts close the amber light will energize and the process may begin again x The relay co...

Страница 4: ...the unit is turned off by depressing the red rocker switch x 115 VAC is removed from the heat circuit x 115 VAC is removed from the drain circuit and the normally open drain valve opens allowing the u...

Страница 5: ......

Страница 6: ...contact of the high pressure switch to the amber reset switch energizing the amber light 3 When the momentary amber switch is depressed 115 VAC is sent to the ice cube relay closing it x The relay la...

Страница 7: ...seconds the WF terminal is energized and the water fill circuit begins again 8 When the unit is turned off by depressing the red rocker switch x 115 VAC is removed from the heat circuit x 115 VAC is r...

Страница 8: ......

Страница 9: ...ressed Yes No No Yes No Replace the high limit pressure switch With the SLWCO switch temporarily bypassed does the Amber light go off with the reset switch depressed No Yes Yes Replace the SLWCO switc...

Страница 10: ...s water leaving the fill solenoid Replace wiring to drain solenoid Does the steamer have the optional intermittent blowdown timer Replace the wiring to the intermittent blowdown timer Is there 120 VAC...

Страница 11: ...PROBLEM Steam Coil Boiler Stops Producing Steam Boiler stops steaming Does the amber light in the reset switch come on Is the temperature sensitive dot surrounded by a yellow circle on the water board...

Страница 12: ...eplace the fill solenoid With a jumper across terminals HI and C on the waterboard is there 120 VAC between L2 and WF Replace the water board Yes The probe circuit is open Check continuity of the prob...