background image

Cleveland

Project  ________________________________

Item  __________________________________

Quantity  _______________________________  

FCSI Section  ____________________________

Approval  _______________________________

Date  __________________________________

1333 East 179 St.,

Cleveland, Ohio, U.S.A. 44110 

Tel: 1-216-481-4900

Fax: 1-216-481-3782

Web Site: www.ClevelandRange.com

Email: [email protected]  

 

SECT.

B

PAGE 

17

0707

SteamChef

TM

6

High Speed Convection Steamer, 

Automatic Water Fill & Drain, Two 45,000

BTU Gas Boiler-Free Counter Type Design

Cleveland Standard Features

n

Cooking capacity for up to six 12" x 20" x 2.5" deep steam table
pans (1/1 G/N, 65 mm) per compartment.

n

High-speed gas convection steamer with open style 1.5 gallon
water reservoir located at the bottom of the cooking compartment
for easy access and maintenance.

n

Fan forced convection steam with patented 

KleanShield

TM

cooking

compartment design.

KleanShield

TM

collects and removes

condensate waste from the cooking compartment. This keeps the
compartment clean, safe from impurities and easy to maintain.
Reduces foaming and avoids contamination of the reservoir water.

n

Automatic water level controls, fills when main power switch is
turned ON, Low Water and High Water probes inside cooking
compartment maintains water levels during cooking, eliminating the
need to manually refill and monitor water level during cooking.
Large overflow port in rear wall. 193

˚

preheat and standby

temperature. High Temperature Safety Shut-off.

n

Steam and Fan Shut Off Control when compartment door is
opened.

n

45,000 BTU (per compartment) high efficency atmospheric gas
boilerless style heating system.

n

Front acess works in a drawer style burners for easy servicing.

n

Includes a 60-Minute Electro-Mechanical Timer, LED Indicator
Lights for Power On and Reset. Timed and Manual Bypass Switch
for constant steaming.

n

Exclusive 

SteamChef

TM

Automatic Drain Control. Compartment

drains when main power is turned OFF via 1/2" ball valve with micro
switch circuitry. Simple 1" NPT drain connection required with water
saving cold water condenser and 3 minute rinse feature.

n

Left Hand Door Hinging: Compartment Doors hinged on the left,
controls on the right.

n

Exclusive, durable 14 gauge stainless steel compartment door and
latch withstands abuse and heavy wear. Two piece compartment
door with free floating inner door is self adjustable and prevents
leaks. Reversible door gasket doubles the life of the gasket.

n

Heavy-duty 4" (102mm) Skid Resistant Adjustable Legs with
Flanged Feet.

n

UL - Gas, UL - Sanitation (NSF Standards).

Shall be a Cleveland 

SteamChef

TM

6

, model (2) 22CGT6, two stacked

single compartment 62,000 BTU high efficency atmospheric gas boilerless

style heating systems.   Front acess "works in a drawer" style burners for easy

servicing. Standard with Compartment Controls and 60-minute electro-

mechanical timer. Capacity for six 2.5" (1/1 G/N, 65 mm) full size steam table

pans per compartment. Includes 1/2" ball valve style automatic drains.

Automatic water level controls. Heavy-duty 14 gauge stainless steel cooking

compartment doors and latches. 

KleanShield

TM

clean cavity protection. 4"

Adjustable Legs. Requires field installation. Includes Stacking Stand, Gas

Flue Exhaust Kit and Common Drain and Water Connection Manifold.

Short Form Specifications

MODEL

:  

c

(2) 22CGT66

n

Stacking combination requires field installation of the steamers,
stand and flue. This combination includes the following items:

• ES263044 Stacking Stand (PN 111467G) 
• Gas Flue Exhaust Kit
• Common Drain and Water Connection Manifold

Options & Accessories

p

5 Foot (1524mm) FDA Approved National Hose Thread style water
connection kit (garden hose thread), 2 required (NHT60)

p

Single Point Water Connection (SPW)

By

STEAMCHEF™ BOILERLESS
CONVECTION STEAMERS

Отзывы: