Cleode ZigBee ZLOCK Скачать руководство пользователя страница 1

 

S.A. au capital de 167 200 

 

R.C.S. Saint Brieuc TGI 450 570 767 

Siège social : 8 rue Bourseul 22300 Lannion France 

Tél. : +33 (0) 2 96 48 68 18 – Fax : +33 (0) 2 96 48 19 11 

 

 

 

ZigBee™ 

command of door lock 

ZLOCK

 

 
 

 

User Manual 

 
 

 

 
Revision: 1.0 
Document: UM_ZLOCK_20110919_001_01_00.doc 
 
 
 

Содержание ZigBee ZLOCK

Страница 1: ...C S Saint Brieuc TGI 450 570 767 Si ge social 8 rue Bourseul 22300 Lannion France T l 33 0 2 96 48 68 18 Fax 33 0 2 96 48 19 11 ZigBee command of door lock ZLOCK User Manual Revision 1 0 Document UM_Z...

Страница 2: ...fects or flaws CLEODE reserves the right to modify the devices in order to comply with the warranty The warranty does not apply to replacement or repairs that may result from normal wear and tear of d...

Страница 3: ...OPYRIGHT 6 II ZLOCK DESCRIPTION 7 II 1 ZIGBEE PRESENTATION 7 II 2 DOOR LOCK APPLICATION 7 II 2 1 DOOR LOCK APPLICATION DESCRIPTION 7 II 2 2 CLUSTERS DESCRIPTION 8 III INSTALLATION AND NETWORK ASSOCIAT...

Страница 4: ...of door lock User Manual UM_ZLOCK_20110919_001_01_00 CLEODE Page 4 sur 16 TABLE OF REVISIONS Version Authors s Version description Date 0 1 CLEODE Initial version 15 09 2011 1 0 CLEODE Validated docum...

Страница 5: ...CLEODE Page 5 sur 16 REFERENCE DOCUMENTS N Document Description 1 ZigBee_Cluster_Library_Public Sp cification de la Zigbee Cluster Library 2 ZigBee_Home_Automation_Profile Sp cification du profile Hom...

Страница 6: ...ZLOCK has this form The module ZLock works in conjunction with a Zigbee coordinator compatible stack pro 2007 CLEODE also markets Coordinators Zigbee Contact support cleode com ou Web www cleode fr f...

Страница 7: ...PRO 2007 and Home Automation profile For more detail on the data exchange between device and network see documents 1 2 and 3 II 2 DOOR LOCK APPLICATION The system of command of door lock allows feed t...

Страница 8: ...ersion 0x0002 HWVersion 0x0003 ManufacturerName 0x0004 ModelIdentifier 0x0005 DateCode 0x0006 PowerSource 0x0007 LocationDescription 0x0010 PhysicalEnvironment 0x0011 DeviceEnabled 0x0012 AlarmMask 0x...

Страница 9: ...ne 0x0001 CurrentGroup 0x0002 SceneValid 0x0003 NameSupport 0x0004 Door Lock This cluster allows knowing the characteristics of the ZLOCK Attribut Identifiant de l attribut Lock State 0x0000 Lock Type...

Страница 10: ...LLATION To mount the ZLOCK with a double sided tape follow this 1 Stick a double sided tape on the ZLOCK bottom 2 Dust the wall 3 Mount the ZLOCK on the wall III 1 2 RACCORDEMENT To connect the ZLOCK...

Страница 11: ...ZigBee command of door lock User Manual UM_ZLOCK_20110919_001_01_00 CLEODE Page 11 sur 16 Connect the door lock on the ZLOCK Attention a single door lock must be connected by ZLOCK...

Страница 12: ...etwork the light of the ZLOCK flashing during 2 seconds then turn off In the cases where the association is not possible the object is going to put itself in sleep and to try automatically to join at...

Страница 13: ...blinking If the association is success the light of the ZLOCK flashing during 2 seconds and turn off If the light of the ZLOCK does not flash after to have press on the button during 3 seconds this m...

Страница 14: ...110919_001_01_00 CLEODE Page 14 sur 16 IV TECHNICAL FEATURES Weight 100 g Power supply Max 24V Commutation Max 3A Measurement 54 x 52 x 32 mm Transmission range 100 m outdoor 30 m indoor Managed chann...

Страница 15: ...number Be prepared to state your name company and the serial number of the defective item to the support personnel The item shall then be returned to CLEODE with the following documents The RMA number...

Страница 16: ...r Manual UM_ZLOCK_20110919_001_01_00 CLEODE Page 16 sur 16 CLEODE S A Technical Support Division 8 rue Bourseul 22300 Lannion France Phone 33 0 2 96 48 68 18 Fax 33 0 2 96 48 19 11 E mail support cleo...

Отзывы: