Cleco LiveWire 943610PT Скачать руководство пользователя страница 6

6

P2332BA | 2019-08

Apex Tool Group

2

EN

2

Safety

Basic requirements

Only operate the socket tray after you have read and 
fully understood this document. Failure to follow the 
directions and safety instructions could result in elec-
tric shocks, burns and/or injuries.

Keep this document in a safe place for future use! 
Make this documentation available to the designer, the 
installer and the personnel responsible for commis-
sioning the machine or system in which this product is 
employed.

Intended use

The product is a part of the Cleco Production Tools tighten-
ing system and is intended exclusively for industrial use in 
fastening processes. Use the socket tray under the follow-
ing conditions:

Only use the socket tray in conjunction with a 
Cleco Production Tools Primary or Master controller.

Use a separate socket tray for each tool.

Only under the specified ambient conditions.

Only with the permissible supply voltage.

Only in areas of EMC Limit Class A (electromagnetic 
immunity for industrial areas). For the currently 
observed EMC standards, see the EC Declaration of 
Conformity.

Remove the battery to store the socket tray.

Operator training

The socket tray may only be commissioned, adjusted and 
tested by qualified and trained personnel. The personnel 
must be instructed by qualified employees

1

 of 

Apex Tool Group. The inserts for the socket tray sockets 
may only be changed by qualified employees

1)

. The socket 

tray may only be adjusted to special requirements by quali-
fied employees

1)

Foreseeable incorrect usage

Do not use the socket tray:

in potentially explosive areas

in damp spaces/outdoors

as a hammer/impact tool 

with outside control or battery 

Only use Apex Tool Group battery charger 24 V 
(935391) for charging.

Power supply

Operation with 26 V battery pack (935377), a 44 V battery 
pack (936400PT) or a PM 48 power module (961350PT).

Operation

Only use the socket tray when it is closed. Operation with 
the device open causes the following:

An increased amount of emissions: this can cause 
interference with other devices.

Reduced immunity from interference: the socket tray 
can produce faulty results.

The loss of existing warranty entitlement.

Warnings and notices

Warning notices are identified by a signal word and a picto-
gram:

The signal word describes the severity and the proba-
bility of the impending danger.

The pictogram describes the type of danger

Structure Of Warnings

Symbols on the product

Make sure that the meaning of the symbols has been 
understood before using the socket tray.

1.Due to their professional training, knowledge, 
experience and understanding of the circumstances 
involved in this kind of work, suitably qualified 
employees are able to identify potential hazards and 
to initiate appropriate safety measures. Qualified 
personnel must comply with regulations.

Note

A symbol combined with the word 

Note

 in-

dicates a potentially 

harmful situation

 

which, if not avoided, could result in dam-
age to property or the environment

.

General instructions 

include application 

tips and useful information, but no warn-
ings against hazards.

Note

Type and source of danger.

Possible consequences of non-obser-
vance.

Measures to avoid danger.

CE compliant

The product corresponds to the prescribed 
technical requirements in Europe.

Read all instructions.

Observe generally valid disposal guide-
lines such as, in Germany, the Electrical 
and Electronic Equipment Act (ElektroG) 
and the Battery Act (BattG).

Содержание LiveWire 943610PT

Страница 1: ...For additional product information visit our website at www ClecoTools com Instruction Manual P2332BA 2019 08 943620PT 943610PT WLAN socket tray...

Страница 2: ...able language or transmitted on electronic mechanical optical or other media without the express permission of the Apex Tool Group Disclaimer Apex Tool Group reserves the right to modify supplement or...

Страница 3: ...ation 10 4 3 Charge battery pack 10 4 4 Installation 10 5 Commissioning 11 5 1 Opening the housing 11 5 2 Configuring the socket tray 11 5 2 1 Installing the USB interface driver 11 5 2 2 Installing t...

Страница 4: ...4 P2332BA 2019 08 Apex Tool Group EN 8 Troubleshooting 19 9 Technical Specifications 21 9 1 General Information 21 9 2 Mechanic dimensions and weights 21 10 Service 21 11 Disposal 21...

Страница 5: ...operation of this equip ment Other documents Symbols in the text Number Type P1970E Operating Manual Battery Pack 935377 P2372JH EC Declaration of Conformity P3315C Installation instructions S168688 L...

Страница 6: ...a hammer impact tool with outside control or battery Only use Apex Tool Group battery charger 24 V 935391 for charging Power supply Operation with 26 V battery pack 935377 a 44 V battery pack 936400PT...

Страница 7: ...he control and function elements Fig 3 2 External control and function elements Fig 3 3 Internal control and function elements Features 943620PT 943610PT Number of inserts 4 8 Select App 1 to 4 1 to 8...

Страница 8: ...The MAC address is defined by Cleco Production Tools and cannot be changed The other data can be changed with LiveWire RF Configuration software via USB connection to the PC 3 3 7 Wireless module The...

Страница 9: ...10PT 1 Pos 17 page 7 0 2 Pos 18 page 7 1 Component Battery pack li ion 26 V Order No 935377 Battery pack li ion 44 V Order No 936400PT Power Module PM48 Order No 961350PT LiveWire Memory Chip LMC Orde...

Страница 10: ...Inserts 4 3 Charge battery pack The battery pack is only partly charged upon delivery Fully charge the battery before using it for the first time See battery pack instruction manual P1970E 4 4 Install...

Страница 11: ...nternal control and function elements Seite 7 position 14 3 Switch on the socket tray 4 Plug the USB connector cable into the mini USB socket on the controller board and connect it to the PC 5 A suita...

Страница 12: ...ace port selected when the USB driver was installed This inter face port can be viewed in the Windows Device Man ager Fig 5 2 Properties of USB serial port COM4 2 Settings for the following can be mad...

Страница 13: ...a little longer about five seconds the first time it is switched on after the firmware download When the firmware has been flash stored the red and green LED display flash After flash storing the boot...

Страница 14: ...ate Status If the system is in the main menu or the submenus press and hold the function key F1 for two seconds to exit the menu level To switch the socket tray off press the on off switch and hold it...

Страница 15: ...evaluates the status of the initiators Connection lost A connection to a nutrunner control exists However the nutrunner control has not commu nicated with the socket tray again within the pro grammed...

Страница 16: ...unctions for the socket tray Administration Displays general points such as serial number software version LMC Shows the LiveWire Memory Chip set tings Wireless transmission Shows settings of wireless...

Страница 17: ...oards MAC address MAC address display Serial number Serial number display Country code Various WLAN frequency ranges are available World worldwide approved US CA approved in the USA EU approved in Eur...

Страница 18: ...of access point Transmission output Transmission output display Channel used Display of channel currently used Channels scanned Display of channels scanned UDP TCP communication protocol Selection of...

Страница 19: ...uration of the expansion board s incorrect Contact Sales Service Centers of the Apex Tool Group LMC is not readable Change LMC LMC is not available Insert LMC Initialization of the WLAN module failed...

Страница 20: ...tings submenu Port 4001 is disabled by a firewall Configure the firewall such that the required IP MAC addresses can use port 4001 The wireless channel at the access point is out side the range suppor...

Страница 21: ...ditions Storage temperature 25 C to 70 C Remove the battery to store the socket tray Ambient temperature 0 C to 45 C Permissible relative humidity 0 90 without condensa tion Electrical specifications...

Страница 22: ...x Tool Group GmbH C O Spline Gauges Piccadilly Tamworth Staffordshire B78 2ER United Kingdom Phone 44 1827 8727 71 Fax 44 1827 8741 28 FRANCE Apex Tool Group SAS 25 Avenue Maurice Chevalier ZI 77330 O...

Отзывы: