Cleco LiveWire 943610PT Скачать руководство пользователя страница 15

Apex Tool Group

P2332BA | 2019-08

15

7
EN

7

LCD

The operating menu on the socket tray is divided into a 
main menu and submenus. You can navigate through the 
menus using the two function keys below the LCD display. 
In the following description, <F1> is used for the left func-
tion key and <F2> is used for the right function key. The 
menu is activated by pressing the right function key <F2>. 

Basic functions

<F2>: Activate main menu.

<F1>: Go to previous menu item.

<F2>: Go to next menu item.

Press <F1> for longer than two seconds to go to the 
next higher menu level.

Press <F2> for two seconds to go to a submenu.

Press the on/off switch: The highlighted entry is acti-
vated, or the highlighted activity is executed. 

When the menu is active, the initiators on the inserts 
do not respond to changes if the sockets are added or 
removed.

At the end of each submenu there is an entry for 

Back

.

7.1 Main function 

After the initialization phase, the connection status to the 
nutrunner control and the operating status are displayed. 

The connection status can be:

Waiting for connection

: Still no connection to a nut-

runner control after switching on. Nothing is indicated 
by the status LEDs and no initiator status is evaluated.

Connection

: A connection to a nutrunner control 

exists. The connection controls the status of the 
status LEDs and evaluates the status of the initiators.

Connection lost

: A connection to a nutrunner control 

exists. However, the nutrunner control has not commu-
nicated with the socket tray again within the pro-
grammed time. This is indicated by alternating 
status LEDs flashing on the inserts of the sockets. 

The display changes automatically between the connection 
status display 

Init.

 and the operating status 

Power

. Func-

tion keys <F1> and <F2> under the LCD can be used to 
change between the connection status display and the 
operating status. After a button is pressed, the display 
freezes for five seconds and then automatically changes 
again.

The connection status is also indicated by the green LED 
display above the LCD. This lights up continually when a 
connection is present.

The operating status is indicated by the red LED display 
above the LCD. These flash if a fault is present. A fault 
here is either an initialization failure or a warning about the 
operating voltage or battery voltage.

7.2 Structure

Activates the main menu.

Back

Main menu
Administration
Diagnostics

Administration

LMC

Serial number

Wireless transmission

Software version

Back

Hardware configura-
tion

Back

Diagnostics
Voltages
LED test
Initiator test
Extension board test
Back

LMC
MAC address
Serial number
Country code
Back

Wireless WLAN
Wireless module 
version

MAC address
IP address
Subnet
Gateway
Host
SSID
BSSID

Signal strength
Roaming
Transmission output
Bands
Channel used
Channels scanned
Baud rate
UDP/TCP communi-
cation protocol

Back

Содержание LiveWire 943610PT

Страница 1: ...For additional product information visit our website at www ClecoTools com Instruction Manual P2332BA 2019 08 943620PT 943610PT WLAN socket tray...

Страница 2: ...able language or transmitted on electronic mechanical optical or other media without the express permission of the Apex Tool Group Disclaimer Apex Tool Group reserves the right to modify supplement or...

Страница 3: ...ation 10 4 3 Charge battery pack 10 4 4 Installation 10 5 Commissioning 11 5 1 Opening the housing 11 5 2 Configuring the socket tray 11 5 2 1 Installing the USB interface driver 11 5 2 2 Installing t...

Страница 4: ...4 P2332BA 2019 08 Apex Tool Group EN 8 Troubleshooting 19 9 Technical Specifications 21 9 1 General Information 21 9 2 Mechanic dimensions and weights 21 10 Service 21 11 Disposal 21...

Страница 5: ...operation of this equip ment Other documents Symbols in the text Number Type P1970E Operating Manual Battery Pack 935377 P2372JH EC Declaration of Conformity P3315C Installation instructions S168688 L...

Страница 6: ...a hammer impact tool with outside control or battery Only use Apex Tool Group battery charger 24 V 935391 for charging Power supply Operation with 26 V battery pack 935377 a 44 V battery pack 936400PT...

Страница 7: ...he control and function elements Fig 3 2 External control and function elements Fig 3 3 Internal control and function elements Features 943620PT 943610PT Number of inserts 4 8 Select App 1 to 4 1 to 8...

Страница 8: ...The MAC address is defined by Cleco Production Tools and cannot be changed The other data can be changed with LiveWire RF Configuration software via USB connection to the PC 3 3 7 Wireless module The...

Страница 9: ...10PT 1 Pos 17 page 7 0 2 Pos 18 page 7 1 Component Battery pack li ion 26 V Order No 935377 Battery pack li ion 44 V Order No 936400PT Power Module PM48 Order No 961350PT LiveWire Memory Chip LMC Orde...

Страница 10: ...Inserts 4 3 Charge battery pack The battery pack is only partly charged upon delivery Fully charge the battery before using it for the first time See battery pack instruction manual P1970E 4 4 Install...

Страница 11: ...nternal control and function elements Seite 7 position 14 3 Switch on the socket tray 4 Plug the USB connector cable into the mini USB socket on the controller board and connect it to the PC 5 A suita...

Страница 12: ...ace port selected when the USB driver was installed This inter face port can be viewed in the Windows Device Man ager Fig 5 2 Properties of USB serial port COM4 2 Settings for the following can be mad...

Страница 13: ...a little longer about five seconds the first time it is switched on after the firmware download When the firmware has been flash stored the red and green LED display flash After flash storing the boot...

Страница 14: ...ate Status If the system is in the main menu or the submenus press and hold the function key F1 for two seconds to exit the menu level To switch the socket tray off press the on off switch and hold it...

Страница 15: ...evaluates the status of the initiators Connection lost A connection to a nutrunner control exists However the nutrunner control has not commu nicated with the socket tray again within the pro grammed...

Страница 16: ...unctions for the socket tray Administration Displays general points such as serial number software version LMC Shows the LiveWire Memory Chip set tings Wireless transmission Shows settings of wireless...

Страница 17: ...oards MAC address MAC address display Serial number Serial number display Country code Various WLAN frequency ranges are available World worldwide approved US CA approved in the USA EU approved in Eur...

Страница 18: ...of access point Transmission output Transmission output display Channel used Display of channel currently used Channels scanned Display of channels scanned UDP TCP communication protocol Selection of...

Страница 19: ...uration of the expansion board s incorrect Contact Sales Service Centers of the Apex Tool Group LMC is not readable Change LMC LMC is not available Insert LMC Initialization of the WLAN module failed...

Страница 20: ...tings submenu Port 4001 is disabled by a firewall Configure the firewall such that the required IP MAC addresses can use port 4001 The wireless channel at the access point is out side the range suppor...

Страница 21: ...ditions Storage temperature 25 C to 70 C Remove the battery to store the socket tray Ambient temperature 0 C to 45 C Permissible relative humidity 0 90 without condensa tion Electrical specifications...

Страница 22: ...x Tool Group GmbH C O Spline Gauges Piccadilly Tamworth Staffordshire B78 2ER United Kingdom Phone 44 1827 8727 71 Fax 44 1827 8741 28 FRANCE Apex Tool Group SAS 25 Avenue Maurice Chevalier ZI 77330 O...

Отзывы: