10
P1993BA/EN 2014-06
1994b_1_5_en-bedingt.fm, 12.06.2014
Before initial operation
4
3.2
Options
4
Before initial operation
4.1
Air supply
Make sure that the pressure before the pressure regulator is at least 0.5 bar higher than the required
inlet air pressure at the tool.
Keep the inside of the air hose free of residue; clean it if necessary.
Air quality
In accordance with ISO 8573-1, quality class 2.4.3, compressed air must be dry and clean.
Air preparation units
Our recommendation: air preparation units (filters, regulators, lubricators) should be installed
Protective sleeve
Order No. 937448PT – 35PHH…
Order No. 937443PT – 35PHHA…
Vibration absorber
Order No. 935965 – 35PHHA…
Parameter
Data
Air hose
Inner diameter 3/8" (ø 9.5 mm), maximum length 5 m
Air inlet
1/4" NPT, inner diameter
7.5 mm
Parameter
Data
Working pressure range
400 … 700 kPa
Max. dew point
+ 10° C
Device
Explanation
Filter
Retention of particles > 15 micrometers.
Removes more than 90% of condensation.
Regulator
To attain constant work results, the working pressure must be
kept constant for every individual tool.
Содержание 35PHH Series
Страница 4: ...4 P1993BA EN 2014 06 1993a_ Deckblatt_en fm 12 06 2014...
Страница 20: ...20 P1993BA EN 2014 06 1994c_Wartung_en bedingt fm 12 06 2014 Maintenance 5 Empty side...
Страница 26: ...26 P1993BA EN 2014 06 1994d_Reparatur_en bedingt fm 12 06 2014 Assembly instructions 7...
Страница 36: ...36 P1993BA EN 2014 06 1993e_Ersatzteile_en fm 12 06 2014 Spare parts 8 8 5 Equipment order list 1 Order no...
Страница 38: ...38 P1993BA EN 2014 06 1993f_TechnDaten_en fm 12 06 2014 Technical data 9 9 2 Dimensions 35PHHA in mm Abb 9 2...