Clearfield WaveSmart Circulator Скачать руководство пользователя страница 8

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • [email protected] 

8

WaveSmart Circulator

Installation Manual 

 _________________________________________________________

Manual 013299 Rev C - Oct 2019

Inspect Then Connect

 

These are Clearfield recommended products/applications. Use the product 

you feel will complete your cleaning procedures. Create a “best practice” for 

your company and follow those procedures.

The use of Chemtronics end face and bulkhead cleaning products and     

techniques ensures a clean end face, no matter the type of contamination.

Before cleaning any connector, be sure you know what type of contaminate 

you are cleaning (dry, fluidic, or combination). All the available products are 

good, it’s the process that you need to be aware of. Using a dry cleaning 

method to clean “dirt” can lead to scratching of the end face. Learn the 

process of cleaning properly.

Note: 

It is 

NOT

 recommended to use isopropyl alcohol to clean the end face.

Cleaning an SC/LC Connector

Cleaning the End Face

• 

Place one wiping paper on QbE-2 FiberSafe™ Cleaning Platen.         

(

Figure 1)

• 

Apply small amount of precision cleaner (about 1” in diameter) with   

Electro-Wash MX pen on to one end of the wipe. (

Figure 2)

• 

Hold end face at a 90 degree angle. For APC connection, adjust by  

slightly tilting the container or end face. Angle is correct when no drag is 

felt on the end face. (

Figure 3)

• 

Draw end face from wet to dry part of the wipe 3 times. Use just enough 

pressure to ensure complete contact between end face and the wipe.

  

Note: DO NOT

 

retrace previous step.

Figure 1

Figure 2

Figure 3

Connector Cleaning Procedure

Whether factory terminated or field spliced, clean connectors are essential for proper system operation. Even the smallest 

dust particle can cause transmission problems, so for optimal network performance inspect, and if necessary, clean 

connectors and adapters prior to mating.

Содержание WaveSmart Circulator

Страница 1: ...WaveSmart Circulator Installation Manual _______________________________________________________ Manual 013299 Rev C Oct 2019...

Страница 2: ...nual __________________________________________________________ Manual 013299 Rev C Oct 2019 Table of Contents Circulator Application 3 Prerequisites 3 Installation Test Turn up Procedure 3 Blue Casse...

Страница 3: ...ses an MLM Multi Longitudinal Mode type laser source fiber relief can still be obtained by imple menting WDM s in place of circulators See your Clearfield representative for more information 1 2 3 4 I...

Страница 4: ...ul completion of Step 7 and verification that the Working path is properly operating via PM Analy sis manually switch live traffic back to Working and retest via PM one last time Insure that all alarm...

Страница 5: ...ect 763 476 6866 National 800 422 2537 www SeeClearfield com techsupport clfd net Manual 013299 Rev C Oct 2019 OC N 1 OC n 2 OC n 4 OC n 3 Before OC n 5 OC n 1 OC n 4 OC n 4 OC n 2 OC n 2 OC n 3 OC n...

Страница 6: ...SeeClearfield com techsupport clfd net 6 WaveSmart Circulator Installation Manual __________________________________________________________ Manual 013299 Rev C Oct 2019 Blue Cassette SC Adapters Dual...

Страница 7: ...________________________________ Installation Manual Direct 763 476 6866 National 800 422 2537 www SeeClearfield com techsupport clfd net Manual 013299 Rev C Oct 2019 xPAK or LGX Cassette SC Adapters...

Страница 8: ...e end face Learn the process of cleaning properly Note It is NOT recommended to use isopropyl alcohol to clean the end face Cleaning an SC LC Connector Cleaning the End Face Place one wiping paper on...

Страница 9: ...e Adapter Itself Lightly moisten the fiber optic swab 2 5mm 38542F or 1 25mm 38040 by spotting a small amount about 1 of Electro Wash PX or Electro Wash MX pen onto the QbE Hold the tip of the swab on...

Страница 10: ...this or an equivalent type swab Cleans ALL MTP MPO connector end faces This swab also cleans the pins of the male connector Lightly spot a QbE 2 wipe on the platen with Electro Wash PX Fiber Optic Cle...

Страница 11: ...aned like a single fiber connector using a cleaning platform The receptacles will be cleaned as long as you are using a combination clean ing process as recommended Again using a platen moisten the pl...

Страница 12: ...tely or through the adapter Slightly engage probe by pulling back but do not allow to click Lightly spot a QbE 2 wipe on the platen with Elec tro Wash PX Fiber Optic Cleaner this will help alleviate o...

Страница 13: ...of Clearfield Inc shall constitute the exclusive sole remedy for a breach of this limited warranty Clearfield shall not be liable under any circumstances for any special consequential incidental punit...

Страница 14: ...plied Every effort has been made to keep the information contained in this document current and accurate as of the date of publication or revision However no guarantee is given or implied that the doc...

Отзывы: