K B - 7 0 1 S P E A K E R S T A T I O N
1 - 3
3.
Speaker:
The audio output for the KB-701 device.
4.
Volume Control:
Turn this control to set the speaker’s required listen level.
This control does not affect the tone alert level or the program input level.
5.
Program Level Control:
Adjust the
program level
control to set the program
audio level heard in the panel speaker.
Note:
Forcing the trimpots past their stop points will damage them.
6.
Integral Microphone:
The microphone for the KB-701 is built into the
front panel.
INTERNAL ADJUSTMENTS AND CONNECTIONS
The controls and connectors inside the KB-701 are shown in the following figure
and described by the following text. The controls can be accessed without
completely removing the panel from its wall box or V-Box enclosure by removing
the top two screws and loosening the bottom two screws a few turns. The panel
can then be leaned out from the wall to make the controls accessible as shown in
the lower view of Figure 1-2.
Figure 1-2: Internal Controls
7.
Call Alert Tone Level Control:
This internal control adjusts the volume of
the
call alert tone
sound. This is normally adjusted when the system is set up
and shouldn’t need to be adjusted during normal operation. This feature can
be disabled by turning the control fully counterclockwise.
An audible tone alert can sound when a call signal is received on the
intercom channel. This can be useful when the operator's attention has been
drawn away from the KB-701 indicator panel. The tone alert will not sound
if a call signal is originated at the KB-701 station.
P3 Must be
installed if
no option
P1 Must be
installed if
no option
1 2 3
10
11
8
7
View from top
of KB-701
Front Panel
12
9