F I M - 1 0 8 F I B E R I N T E R F A C E
2 - 7
CONNECTING COAXIAL CABLE TO THE FIM-108
Use 75-Ohm coaxial cable to connect to the BNC coaxial connectors. Connect
the cables so that:
• transmitter A at one end connects to receiver B at the other end, and
• transmitter B at one end connects to receiver A at the other end.
Figure 5 illustrates an FIM-108 System wired with coaxial cable.
Figure 6: Wiring the FIM-108 to Intercom Stations and Interfaces with Coaxial Cable
Clear-Com Matrix Rear Panel
TO MATRIX
AC - IN
90 - 245 V
RELAY / GPI
J 5
PROG
J 6
SPKR
OUT
J 7
LINE
HMO
J 8
J 9
EXPANSION
OUT
MIC
J 10
J 1
J 2
J 3
i-Station
Wire CAT-5 cable from matrix RJ-45 connectors to FIM-108 "matrix" RJ-45 connectors
Wire CAT-5 cable from FIM-108 "station" RJ-45 connectors to
intercom station and interface RJ-45 connectors
Matrix Port 1
Matrix Port 2
Matrix Port 3
TEL-14 Interface
CCI-22 Interface
Wire coaxial cable from BNC connectors "A" to "B" and "B" to "A"
A
B
B
A
CC/TW
Matrix Direct
Intercom
Call Via
RS-422
Data
4-Wire
Audio
EFI-M Interface