Clear-Com ENCORE MS-702 Скачать руководство пользователя страница 29

W A R R A N T Y                                                    

i

LIMITED WARRANTY

Vitec Group Communications (VGC) warrants that at the time of purchase, the 
equipment supplied complies with any specification in the order confirmation 
when used under normal conditions, and is free from defects in workmanship 
and materials during the warranty period.

During the warranty period VGC, or any service company authorized by VGC, 
will in a commercially reasonable time remedy defects in materials, design, and 
workmanship free of charge by repairing, or should VGC in its discretion deem it 
necessary, replacing the product in accordance with this limited warranty. In no 
event will VGC be responsible for incidental, consequential, or special loss or 
damage, however caused.

WARRANTY PERIOD

The product may consist of several parts, each covered by a different warranty 
period. The warranty periods are: 

• Cables, accessories, components, and consumable items have a limited 

warranty of 90 days.

• Headsets, handsets, microphones, and spare parts have a limited warranty of 

one year.

• UHF wireless IFB products have a limited warranty of one year.

• UHF wireless intercom systems have a limited warranty of three years.

• All other Clear-Com and Drake brand systems and products, including 

beltpacks, have a limited warranty of two years.

The warranty starts at the time of the product’s original purchase. The warranty 
start date for contracts which include installation and commissioning will 
commence from the earlier of date of the Site Acceptance Test or three months 
from purchase.

TECHNICAL SUPPORT 

To ensure complete and timely support to its customers, VGC’s User Support 
Center is staffed by qualified technical personnel. Telephone and email technical 
support is offered worldwide by the User Support Center.

The User Support Center is available to VGC’s customers during the full course 
of their warranty period. Telephone support during the warranty period will be 
offered at no charge between 09:00 and 17:00 according to the customer’s local 
time zone.

In addition, for customers who purchase an Extended Warranty or Service 
Contract, 24-hour customer support is offered immediately upon purchase of 

VGC offers 24 x 7 customer 

support if you have an  

Extended Warranty or 

Service Contract.   

Return Material 

Authorization (RMA) 

numbers are required for all 

returns. 

Both warranty and 

non-warranty repairs are 

available. 

Содержание ENCORE MS-702

Страница 1: ...MS 702 TWO CHANNEL MAIN STATION I N S T R U C T I O N M A N U A L CLEAR COM ENCORE...

Страница 2: ...S A Vitec Group Communications 7400 Beach Drive Cambridge Research Park Cambridgeshire United Kingdom CB25 9TP Vitec Group Communications Room 1806 Hua Bin Building No 8 Yong An Dong Li Jian Guo Men...

Страница 3: ...errupt Options 1 11 INSTALLATION 2 1 MAINTENANCE 3 1 Introduction 3 1 MS 702 Block Diagram 3 1 Troubleshooting Tips 3 2 TECHNICAL SPECIFICATIONS 4 1 MS 702 Two Channel Station 4 1 LIMITED WARRANTY 5 I...

Страница 4: ...M S 7 0 2 T W O C H A N N E L M A I N S T A T I O N i i...

Страница 5: ...ey exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the appa...

Страница 6: ...ts And thereby compliance with the requirement of Electromagnetic Compatibility Directive 2004 108 EC and Low Voltage Directive 2006 95 EC This device complies with Part 15 of the FCC Rules Operation...

Страница 7: ...red to your needs through its programmable options Selectable two channel talking and or listening allows the operator to communicate on either of the intercom channels separately or on both at once T...

Страница 8: ...rating for more than 2 seconds per 1 minute period The MS 702 will operate from any AC line voltage between 100 and 240 volts AC at 50 or 60 Hz The MS 702 installs in a standard 19 inch 48 26 cm equi...

Страница 9: ...button This function activates program interrupts or any other call activated function available on other stations Option switches on the rear panel enable this function SPEAKER MUTE If the front pane...

Страница 10: ...e following procedures to correctly set the sidetone level controls Sidetone Adjustment Procedure for Gooseneck Microphone with Speaker turned on 1 Turn off the party line link A B switch 2 Turn the l...

Страница 11: ...e Link A B Switch When pressed the party line link A B button combines both intercom channels into one for example for rehearsals The party line link button illuminates amber when on and all of the st...

Страница 12: ...PA system announcements It directs the audio from the selected headset or panel microphone to the annc out rear panel connector and activates the announce relay Simultaneously if the program audio fee...

Страница 13: ...channel A and one for channel B These lights illuminate when the MS 702 senses a short or overload on the associated channel When the fault is removed the MS 702 will automatically reset and the light...

Страница 14: ...hot mic output is connected to Clear Com s IFB system and the interrupt external IFB switch is set to the on position pressing a key on the IFB system will disconnect the selected headset or panel mi...

Страница 15: ...r stations on that channel In a multi channel system the goal is to assign specific people to the correct group i e the other people they need to be in contact with the most This is particularly impor...

Страница 16: ...llows Note This adjustment should only be carried out by qualified service personnel Pin 1 Ground shield Pin 2 Signal Pin 3 Signal The audio output is balanced and transformer isolated A shielded twis...

Страница 17: ...e off place the jumper plug over pins 1 and 2 7 Replace the cover of the MS 702 8 Connect the unit to AC mains electricity RE SETTING PROGRAM INTERRUPT OPTIONS When you set one of the front panel Prog...

Страница 18: ...the jumper plug so that it covers pins 2 and 3 This causes call signal activation to interrupt the program audio In the default position the jumper plug covers pins 1 and 2 which causes talk signal a...

Страница 19: ...he mains power requirement is given on the underside of the unit 5 Connect the intercom lines 6 Set the two termination switches on the rear panel to on 7 Set the option switches to the default up pos...

Страница 20: ...M S 7 0 2 T W O C H A N N E L M A I N S T A T I O N 2 2...

Страница 21: ...c Gain Panel Mic Jack XLR4 Main Pgm Program Level A 3 2 SA Output Hot Mic IFB Out Main Pgm Listen A Program Level XLR4 Headset Headset Limiter Line Length Sidetone Null Intercom Line A Program Level B...

Страница 22: ...d short light is illuminated Short or overload on that channel due to a shorted or miswired cable Remove the intercom line cables one at a time from the system until the faulty line is located The red...

Страница 23: ...Set the MS 702 termination switch for that channel to the on position A headset extension cord was used Headset extension cords are not recommended Excessive crosstalk High DC resistance in ground re...

Страница 24: ...I N S T A T I O N 3 4 Table 3 1 Troubleshooting Tips Far too many terminations on the intercom line Check all main stations and power supplies to make sure each intercom channel is terminated at only...

Страница 25: ...eshold 0 dBu 3dB Mic Limiter Range 15 dB Program Line Input Maximum Level before Clipping 20 dBu Input Impedance 5K Headset Output Load Impedance 8 Output Impedance 25 Output Limiter Threshold 5 dBu 3...

Страница 26: ...e Out 0 5 Program Input Party Line 0 2 Program Input Headset Out 0 2 Program Input Speaker Out 0 5 Party Line Headset Out 0 2 Party Line Speaker Out 0 5 Noise Panel Mic Party Line 65 dBu Headset Mic P...

Страница 27: ...or 12 headset stations distributed over both channels Rear Panel Connectors Intercom 6 XLR 3M 3 per channel Announce Out 1 XLR 3M audio Announce Relay 1 1 4 in 0 64 cm phone jack relay Program 1 XLR 3...

Страница 28: ...m x 165 mm Weight 6 06 lbs 2 75 kg Notice About Specifications While Clear Com makes every attempt to maintain the accuracy of the information contained in its product manuals that information is subj...

Страница 29: ...r UHF wireless intercom systems have a limited warranty of three years All other Clear Com and Drake brand systems and products including beltpacks have a limited warranty of two years The warranty st...

Страница 30: ...pment at VGC s expense For out of box failures use the following contact information Europe Middle East and Africa Tel 44 1223 815000 Email customerservicesEMEA vitecgroup com North America Canada Mex...

Страница 31: ...ILITY OR OTHERWISE WITH RESPECT TO THE PRODUCTS OR ANY PART THEREOF DELIVERED HEREUNDER OR FOR ANY DAMAGES AND OR LOSSES INCLUDING LOSS OF USE REVENUE AND OR PROFITS SOME STATES DO NOT ALLOW THE EXCLU...

Страница 32: ...in damage to VGC provided product This limited warranty is not transferable and cannot be enforced by anyone other than the original consumer purchaser This warranty gives you specific legal rights an...

Отзывы: