Eclipse Median Instruction Manual
4 - 9
cards should have the DECT Sync links between matrices to ensure
the correct operation of the FreeSpeak/CellCom system.
Multiple E-Que cards within a single matrix do not need to have
external DECT sync cables connected as the signal uses the
backplane.
Figure 4-5: Multiple Matrices with DECT Sync Interconnect
All connections are made using CAT5 cable and it is recommended
that shielded cable is used.
Note: If an E-Que card is fitted in the Omega with antennae or
splitters connected and active inserting a second E-Que
card to the left of the first card (seen from the front) will
cause a temporary loss of audio to beltpacks using the
original E-Que card (usually for about 10 seconds). The
beltpacks do not go offline and signalisation is not lost.
Matrix 1
Matrix 2
E-Que
Card 1
E-Que
Card 2
Splitter 1
Splitter 2
DECT
Sync
LAN
Out