Vitec Group Communications
Eclipse Median Instruction Manual

2 - 1 3

MAIN ALARM LIGHT 

An alarm condition triggers the following events: 

• The red main alarm light flashes. 

• The matrix’s internal alarm buzzer sounds. 

• Any installed alarm relay outputs switch to active (the normally open 

contact closes and the normally closed contact opens). When the 
alarm relay activates, it can cause an externally connected device 
like a light or buzzer to switch on. 

• One of the six auxiliary red alarm lights may go on to more precisely 

indicate the source of the alarm condition. (These lights are 
discussed in further detail later in this section.)

ALARM RESET BUTTON

When you press the alarm reset button, the following events take 
place, even if the alarm condition has not been corrected: 

• The internal audible alarm buzzer stops buzzing. 

• Any wired relay contacts return to their inactive state. If these relays 

are connected to external alarm lights or alarm buzzers, those 
lights or buzzers shut off.

If the original alarm condition still exists, the red main alarm light on the 
matrix’s front panel continues to flash. The red main alarm light only 
stops flashing when all original sources triggering the alarm are 
corrected. 

If a new alarm condition or conditions occur before the original alarm 
conditions are corrected, the internal buzzer and relay contacts will not 
reactivate. They will only reactivate after all original alarm conditions 
are corrected. 

AUXILIARY ALARM LIGHTS  

When an alarm condition occurs, any of the six auxiliary alarm lights 
may switch on, in addition to the main alarm light, to help you diagnose 
the alarm condition. The following sections describe the six auxiliary 
alarm lights. 

External Alarm (“Ext Alarm”)

The “external” alarm (labelled “EXT ALARM”) light switches on to 
indicate that an alarm condition has triggered the built-in relay outputs 
to turn on any externally installed alarms such as lights or bells. You 
connect the external alarm to the matrix through the 9-pin D-type 
connector on the matrix’s rear panel labeled “Alarm I/O.” 

Содержание Eclipse Median

Страница 1: ...ECLIPSE MEDIAN MATRIX Frame and Circuit Cards Instruction Manual Includes update for GPI Pinout at the end of the manual...

Страница 2: ...meda CA 94501 U S A Vitec Group Communications Ltd 7400 Beach Drive IQ Cambridge Cambrideshire United Kingdom CB25 9TP Vitec Group Communications Room 1806 Hua Bin Building No 8 Yong An Dong Li Jian G...

Страница 3: ...ECS 1 6 Intercom and Accessory Panels 1 6 Interface Frames 1 7 OPERATING AN ECLIPSE MEDIAN 2 1 Using the Eclipse Median Matrix 2 1 Central Processor Unit CPU Card 2 2 Creating and Storing System Confi...

Страница 4: ...tton 2 13 Auxiliary Alarm Lights 2 13 External Alarm Ext Alarm 2 13 Temp Alarm 2 14 Fan Fail Alarm 2 14 PSU1 Fail 2 14 PSU2 Fail 2 14 Fan On Indicator 2 15 Power Supply Lights 2 15 Connecting the Matr...

Страница 5: ...9 Dual Card Set Redundancy 3 9 Loss of Single Fiber Connection 3 10 Loss of a Single Node 3 10 Loss of Two Fiber Connections 3 10 Loss of Two Nodes 3 12 Fiber Optic Linking Card Failure 3 12 Fault To...

Страница 6: ...Verifying Port Card Installation 5 10 Installing Interfaces in the Median 5 10 Wiring Remote Devices to the Matrix 5 11 Wiring Panels to the Matrix 5 11 4 Pair Analog 5 11 Single Pair Digital 5 13 Wi...

Страница 7: ...eneral Principles 6 3 Specific Troubleshooting Examples 6 4 Troubleshooting Data Problems 6 6 General Principles 6 6 Specific Troubleshooting Examples 6 8 System Block Diagram 6 8 SPECIFICATIONS 7 1 M...

Страница 8: ...Vitec Group Communications Eclipse Median Instruction Manual vi...

Страница 9: ...igure 4 6 Matrix to Matrix Direct E1 Trunking 4 10 Figure 4 7 E1 Trunking via an E1 Network 4 11 Figure 4 8 Matrix to Third Party Connection Using E1 4 11 Figure 4 9 Matrix to Matrix T1 Trunking 4 12...

Страница 10: ...Eclipse Median Instruction Manual ii 5 20 Figure 5 15 Pin Assignments for Eclipse Median General Purpose In puts Connector 5 21 Figure 5 16 Pin Assignments for LAN1 and LAN2 Connectors 5 22 Figure 6...

Страница 11: ...rician for replacement of the obsolete outlet 7 Protect power leads from being walked on or pinched particularly at plugs at convenience receptacles and at the point where they exit from the apparatus...

Страница 12: ...for audio video audio visual and entertainment lighting control apparatus for professional use Part 2 Immunity UL60065 7th edition CAN CSA C22 2 No 60065 03 IEC 60065 2001 7th edition And thereby comp...

Страница 13: ...dio quality The system maintains 24 bit sampling and 30 Hz to 22 kHz frequency response Up to seven available port cards supporting 16 ports each for connecting to panels and interfaces Slots housing...

Страница 14: ...ctionality provides E1 and T1 trunking and E1 audio tie lines to a 4000 system as mentioned later on OVERVIEW OF A MEDIAN SYSTEM A complete Eclipse Median system consists of a central matrix and the r...

Страница 15: ...e cards slide vertically into the front of the matrix and connect to the matrix s backplane CPU Card The CPU card is the master configuration card in the Eclipse Median system It provides the serial d...

Страница 16: ...red in various ways to provide protection against the loss of a link or a node Each fiber card link consists of a front card with various status indicators and a rear card with two Duplex LC Terminate...

Страница 17: ...3 IMF 102 and DIF 102 See the manual Interface Module Frames in the Eclipse manual set for more information Note The DIG 2 and VeNiX ISDN modules are not compatible with the Median frame format POWER...

Страница 18: ...vices assign a label to each port panel and inhibit or enable features at any connected panel You can set up the system to run on a client server model over a network allowing you to control the matri...

Страница 19: ...rix via double shielded 24 AWG conductor category 6 enhanced CAT 6E STP cable The type of cable used to connect the interface module to the non 4 wire device varies with the device Each of these conne...

Страница 20: ...Vitec Group Communications Eclipse Median Instruction Manual 1 8...

Страница 21: ...ones or two way radios to the matrix Two Euro Cassette power supplies provide fail safe redundancy in the event of a component failure or an AC circuit outage Front panel lights give you information a...

Страница 22: ...features When you connect an external computer to the matrix you can retrieve the current configuration information stored in the CPU microprocessor s memory using the Eclipse Configuration Software a...

Страница 23: ...reason the system will automatically switch to the second card as backup OPERATING THE CPU CARD The following sections describe the CPU card s status lights and controls which are illustrated in Figu...

Страница 24: ...ction Manual 2 4 DOT MATRIX LIGHTS The rectangular array of lights just below the power supply lights displays a number either 1 2 3 or 4 to indicate the currently selected configuration The Eclipse C...

Страница 25: ...upply is on When lit 3 3 volt power supply is on When flashing software is running Blinks when two CPU cards are exchanging information When lit this CPU card is acting as master card Blinks when LAN...

Страница 26: ...illuminates on whichever CPU card is currently serving as master If there is a backup CPU card in the matrix its master light will not illuminate if the primary card is acting as master LAN A Light Wh...

Страница 27: ...s the system s active operational configuration ENGINEERING ENG BUTTON This button is used to reset the system to the default IP addresses FULL RESET BUTTON When you perform a full reset all cards in...

Страница 28: ...verall state of the system RESET BUTTON Pressing the reset button causes the card and all connected audio devices to momentarily stop their current activity and to restart The card s frame data light...

Страница 29: ...uminates to indicate successful communication between the port card and the CPU card STATUS LIGHT The red status light illuminates to indicate a failure in communication between the port card and the...

Страница 30: ...faces can be connected FRAME DATA LIGHT The green frame data light illuminates to indicate successful communication between the port card and the CPU card STATUS LIGHT The red status light illuminates...

Страница 31: ...mperature inside the Eclipse matrix exceeds a threshold both an audible alarm and a warning light switch on allowing you to diagnose and correct power anomalies while the system remains in operation E...

Страница 32: ...a matrix relay to turn on an external alarm If the active CPU card exceeds a temperature threshold If either of the CPU cards is removed from the matrix If either of the matrix s two cooling fans stop...

Страница 33: ...rm lights or alarm buzzers those lights or buzzers shut off If the original alarm condition still exists the red main alarm light on the matrix s front panel continues to flash The red main alarm ligh...

Страница 34: ...lf also switches on to indicate the same condition One of the green power supply lights may then switch off to help indicate the source of the trouble Note that the PSU1 fail light only works if the f...

Страница 35: ...ted in a power supply and extra cooling is required a second fan switches on to increase the air flow The fan on alarm light illuminates red to indicate that the second fan is on POWER SUPPLY LIGHTS T...

Страница 36: ...he next section A port card rear panel holds the sixteen RJ 45 connectors associated with its corresponding front panel port card Remote intercom panels and interfaces connect to the matrix through th...

Страница 37: ...conjunction with this card All other cards however require their own rear connector panel Figure 2 6 CPU Card s Rear Connector Panel CONNECTING TO A GPI RLY INTERFACE The RJ 45 socket labeled GPI RLY...

Страница 38: ...25 pin D type socket labeled GP OUT connects the CPU card to eight general purpose outputs GPOs General purpose outputs are single pole double throw relays with contact ratings of 30 VDC volts direct...

Страница 39: ...hernet connection The green LED indicates the port is connected and the amber LED indicates activity If you use this port you must add a ferrite to the socket end of each cable A suitable ferrite is W...

Страница 40: ...dentifying its card number and port number In Figure 2 7 for example the sixteen ports for the first card are designated 1 1 1 2 1 3 and so on Figure 2 7 Eclipse Median Rear Panel Port Numbering Grid...

Страница 41: ...nd link activity The link status and activity LEDs indicate whether there is activity on a link whether the card is transmitting on a link and the error state of a link Normally fiber cards should be...

Страница 42: ...t to this green light When lit the light indicates that the 3 3 volt supply is present and supplying electric current to the card Processor LED When lit the LED indicates that the fiber card on board...

Страница 43: ...this card STATUS LIGHT When flashing this light indicates card status When lit 3 3 V power supply is on When lit the processor is running When lit the front card is functioning When lit the rear card...

Страница 44: ...he primary fiber optic circuit Secondary Link Status LEDs These LEDs indicate the status and functioning of the secondary B fiber optic link Link LED This LED indicates whether a link has been establi...

Страница 45: ...ECTIONS The fiber card rear card contains a single power supply indicator LED and two fiber connectors Figure 3 2 Rear Fiber Card 6 3 3V When lit 3 3 V power supply is on TXVRB TXVRA Secondary Fiber P...

Страница 46: ...fiber optic cable for the primary and secondary circuits are plugged into the appropriate ports An example showing three systems configured with a primary and secondary ring is shown in Figure 3 3 Fi...

Страница 47: ...t the fiber card downstream from the break and the link status LEDs may show amber Other fiber cards will intermittently show red as the ring attempts to recover If the system layout is displayed by E...

Страница 48: ...then the system will switch to the secondary ring The self healing mechanism is performed automatically by the Fiber Linking Card whereas the switch over between redundant cards and rings requires so...

Страница 49: ...ions for configuration and data transmission but there will be no audio path between them Loss of Two Nodes If two adjacent nodes are lost on the ring this will be handled as for the loss of a single...

Страница 50: ...hat the active ring is unable to heal itself the the system will switch to the secondary ring Switching to the secondary ring will cause audio breaks or disturbances and temporary loss of crosspoint d...

Страница 51: ...where the nodes adjacent to the failed node will loop back their connections to the failed node healing the ring The configuration software will report the failure correctly as two failed cables If tw...

Страница 52: ...ill be handled as for the loss of a single node where the nodes adjacent to the failed node will loop back their connections to the failed nodes healing the ring The configuration software will report...

Страница 53: ...io breaks or disturbances and loss of crosspoint information or data for up to 5 seconds after the fault condition is cleared or repaired Single Card Set Redundant System Fiber Redun dancy In all faul...

Страница 54: ...Vitec Group Communications Eclipse Median Instruction Manual 3 1 4 Figure 3 6 Example of Fiber Optic Connection Setup...

Страница 55: ...30 audio channels on each of 2 connectors 60 channels in total are available in E1 mode while 24 audio channels on each of 2 connectors 48 channels per card in total are available in T1 mode Each E Qu...

Страница 56: ...ent it from being accidentally pressed You need a tool such as a bent paper clip to press this button Power Supply Status Lights 3 3 Volt Power Supply Light The matrix s 3 3 volt power supply provides...

Страница 57: ...light illuminates to indicate data is passing through the ethernet port LAN LINK LIGHT The amber LINK light illuminates to indicate a connection on the LAN port When lit 3 3 V power supply is on 8 yel...

Страница 58: ...e card s 8 yellow status lights corresponds to one of 8 ports to which devices can be connected LAN Data Light The green LAN DATA light illuminates to indicate there is data passing through the ethern...

Страница 59: ...d such that the leftmost card seen from the front is always the one which generates this signal This means that if the leftmost card is removed or a new card is fitted to the left of existing cards th...

Страница 60: ...nnections to other systems Information on E1 and T1 cable pinouts and cable connections are given in chapter 5 FREESPEAK CELLCOM APPLICATION The E Que cards can be configured for FreeSpeak CellCom use...

Страница 61: ...Vitec Group Communications Eclipse Median Instruction Manual 4 7 Figure 4 3 E Que Card Antenna Connection E Que Rear E1 T1 E1 T1 E1 T1 E1 T1 E1 T1 E1 T1 E1 T1 E1 T1 Antennas Matrix...

Страница 62: ...splitter and may be required if the antenna is located more than 300 meters 925 feet from a splitter It is recommended even when the transceiver antenna is closer whenever it is available and conveni...

Страница 63: ...th DECT Sync Interconnect All connections are made using CAT5 cable and it is recommended that shielded cable is used Note If an E Que card is fitted in the Omega with antennae or splitters connected...

Страница 64: ...des 30 channels of G 722 encoded audio are available on each port giving 60 channels per card The E1 specifications are HDB3 Encoding Long Haul Receive Signal Level E1 120 Ohm Transmit Pulse Amplitude...

Страница 65: ...CAT5 cables rather than crossover CAT5 cables Figure 4 7 E1 Trunking via an E1 Network The E Que card can also be used to connect the matrix to third party equipment using an E1 port Figure 4 8 Matrix...

Страница 66: ...rt giving 48 channels per card The T1 trunking specifications are B8ZS Encoding Extended Super Frame Long Haul Receive Signal Level T1 Long Haul LBO 0 dB Transmit Pulse Amplitude Balanced 120 Ohm Line...

Страница 67: ...FAILOVER Where the E1 T1 trunking has been configured with redundant trunks audio will be switched from the primary trunk to the backup trunk when a failure is detected When failover occurs from prim...

Страница 68: ...Vitec Group Communications Eclipse Median Instruction Manual 4 1 4...

Страница 69: ...3 Lift the jumper plug off the pins and place it over pins 1 and 2 This is the ON position The battery is now powered On older Eclipse Median CPU cards the battery is normally a CR2430 3V VARTA 6430...

Страница 70: ...need to temporarily deactivate the CPU backup battery before storing it This preserves CPU backup battery life To do so put the CON9 jumper in the OFF position as described above When you wish to powe...

Страница 71: ...r to the circuits that the terminals are connected to Whenever you are servicing the battery make sure that the jumper on CON9 is connecting pin 2 common to either pin 1 on or to pin 2 off If the comm...

Страница 72: ...sette power supplies are provided to ensure that every matrix will have redundant power that is to ensure that the matrix will continue to operate even if one supply output fails Each of the power sup...

Страница 73: ...ing the panel out INSTALLING CPU CARDS The CPU card s components include CMOS chips which are sensitive to static electricity Before touching the CPU card with your hands touch a grounded metal object...

Страница 74: ...matrix error log in ECS An example of this is shown in Figure 5 3 Figure 5 3 Maintenance Mode Error Log Messages Store spare CPU cards in unused slots in the matrix or in electrically insulated packag...

Страница 75: ...tabs located at the top and bottom of the CPU card hold the card in place in the matrix To remove a card open the two ejector tabs at the same time until the card unseats from its backplane connectors...

Страница 76: ...rd the backplane connectors 3 When the card has almost reached the backplane connectors open the two ejector tabs allowing them to clear the edges of the matrix Gently insert the card further until it...

Страница 77: ...SLOT NUMBERING Each port and expansion card has circuitry to support 16 ports A grid printed on the matrix s rear panel gives the numbering scheme for the ports as shown in Figure 5 4 Figure 5 4 Eclip...

Страница 78: ...ame data light illuminates green when information has successfully passed between the CPU card and the port card The red status light illuminates when the port card fails to communicate with the CPU c...

Страница 79: ...power supply combinations If you connect each AC input to a different mains AC branch one power supply will continue to operate if the other supply s mains AC branch opens WIRING PANELS TO THE MATRIX...

Страница 80: ...Matrix Audio Output from Matrix Audio Output from Matrix Audio Input into Matrix RS 422 Output from Matrix RS 422 Output from Matrix 1 2 3 5 6 7 1 2 6 7 8 4 3 4 5 8 RS 422 Output from panel RS 422 Ou...

Страница 81: ...re that the select switch on the panel rear is in the correct position for the intended use Figure 5 6 Wiring from the Matrix to a Digital Panel Using RJ 45 Note This wiring diagram refers to the Digi...

Страница 82: ...nputs GPIs Eight general purpose outputs GPOs or relays Two separate local area network LAN connections for Ethernet based communication with a network An external GPI RLY interface Figure 5 7 CPU Car...

Страница 83: ...TO A COMPUTER The DB 9 connector labeled RS 232 connects the Eclipse matrix to an external computer To connect a computer to the matrix run cable from the matrix s RS 232 connector to the PC s serial...

Страница 84: ...ic circuit connected to the power supply is activated 4 If either of the two power supply unit fans stop operating 5 If software on a master CPU card generates an alarm An alarm condition activates th...

Страница 85: ...5 10 Wiring the Alarm I O Connector to an Alarm Relay Con nector Figure 5 11 Eclipse Median Matrix s Double Pole Double Throw Alarm Relay WIRING TO GENERAL PURPOSE OUTPUTS The DB 25 connector labeled...

Страница 86: ...ELAY 1 Common RELAY 1 Normally Closed RELAY 1 Normally Open RELAY 2 Common RELAY 2 Normally Closed RELAY 2 Normally Open RELAY 3 Common RELAY 3 Normally Closed RELAY 3 Normally Open 30 VDC at 1 Ampere...

Страница 87: ...or In this mode a DC voltage of between 7 and 24 volts is required at the EXTVIN pin with relation to the EXTVIN pin To cause an input to detect an active signal you must send current from the relevan...

Страница 88: ...ive input and at least 5 mA to cause an active input The opto isolator drive line contains a 1 5 kOhm resistor to limit the current through the opto isolator You can therefore connect the input pins d...

Страница 89: ...Vitec Group Communications Eclipse Median Instruction Manual 5 2 1 Pin Assignments for General Purpose Inputs Connector Figure 5 15 Pin Assignments for Eclipse Median General Purpose Inputs Connector...

Страница 90: ...KS The LAN1 and LAN2 connectors have standard Ethernet pin assignments Figure 5 16 Pin Assignments for LAN1 and LAN2 Connectors 8 7 6 5 4 3 2 1 LAN1 and LAN2 Ethernet RJ 45 Connectors PIN FUNCTION 1 2...

Страница 91: ...Crossover Cable E1 T1 STRAIGHT CABLE CONNECTIONS Table 5 3 Connections for E1 T1 Straight Cables E1 T1 straight cables may be used to connect E1 or T1 ports to E1 or T1 networks or thrid party equipm...

Страница 92: ...r are straight through cables The E1 pinout for connection to an antenna or splitter is shown in Table 5 4 The cable wiring is shown in Table 5 5 Table 5 4 FreeSpeak CellCom E1 Cable Pinout Table 5 5...

Страница 93: ...uld be cleaned at least once a year To clean the matrix shut off AC power remove all cards and use compressed air to remove any dust buildup in the matrix itself Clean all cards with a brush to remove...

Страница 94: ...the necessary forewarning to diagnose and correct any power anomalies while the system remains operational The sensor can also activate an external alarm connected to the matrix such as a light or be...

Страница 95: ...the trouble is occurring Solving power supply problems starts with identifying the specific component causing the problem Note The matrix s backplane connectors are part of the matrix s infrastructur...

Страница 96: ...eneral principles in mind The following examples describe specific problems and suggested solutions Problem All of the power supply lights do not illuminate on one port card Before repairing or replac...

Страница 97: ...placement In the meantime another matrix can be substituted for the damaged one Clear Com will send you a matrix to use while the damaged one is being repaired Problem The power supply lights do not i...

Страница 98: ...ower supply swap it out with a new power supply If this repairs the problem the problem was in the power supply If the problem persists even after the power supply has been replaced the problem is in...

Страница 99: ...ightly recessed from the front panel to prevent it from being accidentally pressed You need a tool such as a bent paper clip to press this button CPU Card Full Reset Button When you press and hold the...

Страница 100: ...CPU card s power lights If any of the lights are not lit replace the card 2 Check the port card s input and output gain settings in the program software 3 Check the panel s listen level adjustment set...

Страница 101: ...cal Height 10 6 inches 267 mm or 6 RU Width 19 inches 482 mm Depth 16 inches 410 mm Front Card Depth 300 mm Weight 20 to 35 kg Environmental Operating Temperature 0 C to 40 C Storage Temperature 55 C...

Страница 102: ...le Specification Cable Type Single Mode 9 125 Fiber Transceiver Specification Type SR1 Short Range SFP Transceiver Minimum Power Budget 8 5dB Wavelength 1310nm Connector Duplex LC Standard Max Node Le...

Страница 103: ...300 Hz to 10 kHz 0 1 0 dBu 100 Hz to 20 kHz Data Interface 16 bi directional Input Format RS 422 2400 to 19200 kb s Output Format RS 422 2400 to 19200 kb s Input Termination 100 ohm 10 Output Termina...

Страница 104: ...Cassette Quantity 2 per matrix Mounting Front Backplane Connectors Positronics AC Power Input IEC 1 per PSU Input Voltage AC 100 V to 240 V 50 60 Hz Power Consumption 300 W maximum Status Indicators L...

Страница 105: ...ectors which connect the matrix s hardware to stations panels and interfaces Destination A device such as an intercom station beltpack or interface to which you send audio signals The device from whic...

Страница 106: ...rmware ROM that is not lost when the power is turned off Panel Another term for station Any intelligent intercom device connected to the rear panel ports of the central matrix This term does not refer...

Страница 107: ...dian Instruction Manual 8 3 VOX In the Eclipse Median system when audio at a station exceeds a threshold a light switches on at the station s port card to visually cue you The threshold level is set i...

Страница 108: ...Vitec Group Communications Eclipse Median Instruction Manual 8 4...

Страница 109: ...4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 PIN DESCRIPTION 1 2 3 4 Logic Input 3 Logic Input 4 N A N A N A N A Ground Ground Ground Ground Logic Input 5 Logic Input 6 Logic Input 7 L...

Страница 110: ...Eclipse V5 0 Clear Com Communication Systems GPI Pinout Addendum 2 Clear Com Communication Systems...

Страница 111: ...warranty of 90 days Headsets handsets microphones and spare parts have a limited warranty of one year UHF wireless IFB products have a limited warranty of one year UHF wireless intercom systems have...

Страница 112: ...ailures use the following contact information Europe Middle East and Africa Tel 44 1223 815000 Email SalesSupportEMEA vitecgroup com North America Canada Mexico Caribbean US Military Tel 1 510 337 660...

Страница 113: ...NOT APPLY TO YOU IN ANY EVENT TO THE MAXIMUM EXTENT PERMITTED UNDER APPLICABLE LAW VGC S LIABILITY TO CUSTOMER HEREUNDER SHALL NOT UNDER ANY CIRCUMSTANCES EXCEED THE COST OF REPAIRING OR REPLACING AN...

Страница 114: ...Vitec Group Communications Warranty i v...

Отзывы: