8)
If the upgrade has been completed disable the CPLD upgrade functionality by
setting the DIP switches to the following settings and downloading the regular
9.0 CPU card application into the CPU card.
5.9
Upgrading the CPU card U53 CPLD code with
Xilinx tools
Use the following procedure to upgrade the U53 CPLD code for the CPU card.
To upgrade the CPU U53 CPLD code with Xilinx tools:
1)
Check that you have the latest version of Xilinx tools installed.
Tip:
Upgrading the CPU card(s) CPLD code using Xilinx tools requires specialized
equipment. For more information about installing Xilinx programming tools, see
2)
Connect the USB connector of the download cable (Platform cable USB DLC9G)
to the USB port of the PC.
3)
Connect the 14way IDC header to CON11.
4)
Power up the CPU card and start the iMPACT programming tool.
5)
In
Load Project
, select
Cancel
.
6)
Hold the CPU card in reset by inserting a suitable tool into the
Reset
pin at the
top of the card. You must press and hold the reset pin during the whole upgrade
process.
7)
In
Flows
, double click
Boundary Scan
. Right click the main window and select
Initialise Chain
/ Ctrl+ I
:
Содержание Eclipse HX series
Страница 1: ...Eclipse Upgrade Guide Part Number 399G240 Rev A Date 07 August 2017 User Guide...
Страница 119: ...Eclipse Upgrade Guide Page 119 21 Power down the MVX A16 card and remove the Xilinx programming tool...
Страница 146: ...Eclipse Upgrade Guide Page 146 Figure 10 2 IVC 32 LMC 64 MK2 card detail...
Страница 195: ...Eclipse Upgrade Guide Page 195 Figure 16 5 FPGA upgrade completed c Reset the card to complete the upgrade...
Страница 203: ...Eclipse Upgrade Guide Page 203 Normal running watchdog enabled settings for CPU card DIP switches...
Страница 204: ...Eclipse Upgrade Guide Page 204 Appendix C PiCo card layout...
Страница 206: ...Eclipse Upgrade Guide Page 206 Figure 17 4 Normal running watchdog enabled settings for Eclipse HX PiCo DIP switches...
Страница 221: ...Eclipse Upgrade Guide Page 221 Figure 17 26 Completion screen Click Finish to exit the installer...