background image

(866) 455-2135

 

[email protected]

 

www.cleanleaf.com

 

OWNER'S MANUAL 

CL2500D Series 

Installation and Service Manual 

INTRODUCTION 

SPECIFICATIONS 

UNPACKING 

MOUNTING 

ELECTRICAL 

OPERATION 

MAINTENANCE 

REPLACEMENT PARTS 

TROUBLESHOOTING 

***IMPORTANT*** 

THIS  MANUAL  CONTAINS  PRECAUTIONARY  STATEMENTS  RELATING  TO  WORKER 

SAFETY. READ AND SAVE THIS MANUAL COMPLETELY AND COMPLY AS DIRECTED. 

ALL  THE  POTENTIAL  HAZARDS  OF  DUST  AND  MIST  CONTROL  SYSTEMS  AND 

EQUIPMENT  ARE  IMPOSSIBLE  TO  LIST;  THEREFORE,  OBTAIN  THE  SERVICES  OF  A 

PROFESSIONAL INSTALLER. A FIRE PROTECTION EXPERT SHOULD BE OBTAINED IN 

THE  EVENT  THE  PRODUCT  IS  INTENDED  FOR  USE  THAT  PRESENTS  A  POTENTIAL 

RISK OF FIRE OR FIRE PROPAGATION. REFER TO APPROPRIATE AUTHORITIES, AND 

DISCUSS  YOUR  INTENDED  USE  WITH  AIR  CLEANING  SPECIALISTS,  INC.  WORKERS 

HANDLING  EQUIPMENT  OR  SYSTEMS  SHOULD  BE  INSTRUCTED  TO  CONDUCT 

THEMSELVES IN A SAFE MANNER. 

RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. 

Содержание CL2500D Series

Страница 1: ...AS DIRECTED ALL THE POTENTIAL HAZARDS OF DUST AND MIST CONTROL SYSTEMS AND EQUIPMENT ARE IMPOSSIBLE TO LIST THEREFORE OBTAIN THE SERVICES OF A PROFESSIONAL INSTALLER A FIRE PROTECTION EXPERT SHOULD B...

Страница 2: ...L2500D CF PCO 2400 ACFM CL2500D HE 1800 ACFM Motor PSC Type 3 4hp Direct Drive with Thermal Overload Switch Two Speed Switch Blower 10 by 10 Direct Drive Centrifugal Forward Curve Grille Four way Indi...

Страница 3: ...xplosion relief vents are required on some applications Consult with an insurance underwriter or an NFPA manual to determine proper vent size ratio Dust or mist collectors must be located outdoors unl...

Страница 4: ...l requirements you should follow the National requirements If the optional Drain Plug was installed in your unit you can connect an appropriate 3 8 I D rubber hose for oil mist routing All chains hook...

Страница 5: ...CLEANLEAF CL2500D Installation Mounting Options Option 1 Mounting w Eye Bolts Option 2 Mounting Strut Channel www cleanleaf com 866 455 2135 info cleanleaf com...

Страница 6: ...866 455 2135 info cleanleaf com www cleanleaf com Option 3 Wall Mounting w L Brackets Bolt to Mounting Bracket Bolt to Wall L Brackets should be 6 from the ends of the unit...

Страница 7: ...then it is time to change main filter The reading may vary depending upon the contaminants Please consult your Sales Engineer for further information FILTERS All units are equipped with replaceable ty...

Страница 8: ...CL2500D Wiring Diagram CL2500D w 3 Speed Switch Wiring Diagram www cleanleaf com 866 455 2135 info cleanleaf com...

Страница 9: ...Speed SWITCH 6 25 2002 12 POWER CORD 7 25 3000 4 WAY ADJUSTABLE LOUVER CL2500 Replacement Filters ITEM PART DESCRIPTION 8 CLF 4404 24 x 24 x 4 Pleated Prefilter 9 CLF PCO Photocatalytic Oxidizers PCO...

Страница 10: ...and open all dampers if installed Check ducting for blockage if installed Check for dirty or blocked filters refer to Maintenance section Check rotation of fan Excess vibration Check structural suppo...

Страница 11: ...nameplate current rating Check motor load If the motor has manual re set thermal protector check if it has been tripped Motor may be overloaded Reduce load Increase motor size If permanent split capa...

Страница 12: ...r horsepower motor Reduce system restrictions blower Increase system restriction blower fan Motor overheats while running under load Overload Reduce load increase motor size Dirt preventing ventilatio...