cleanAIR BASIC 2000 Скачать руководство пользователя страница 6

7

Selection of the filter acc. to the type of contamination

Ordering code 

Filter type * 

Colour code 

Type of contaminant 

50 00 48 

PSL 

White 

Solid and liquid particles (Aerosols) 

50 01 56 

Brown 

Organic gases and vapours with boiling point >65°C 

50 01 57 

APSL 

Brown 

White 

Organic gases and vapours with boiling point >65°  

Solid and liquid particles (Aerosols) 

50 01 67 

ABPSL 

Brown 

Grey 

White 

Organic gases and vapours with boiling point >65° 

Inorganic  gases  and  vapours  such  as  Chlorine,  hydrogen 

sulfid (H2S), hydrogen cyanide (HCN)  

Solid and liquid particles (Aerosols) 

50 01 68 

ABEKPSL 

Brown 

Grey 

Yellow 

Green 

White 

Organic gases and vapours with boiling point >65° 

Inorganic  gases  and  vapours  such  as  Chlorine,  hydrogen 

sulfid (H2S), hydrogen cyanide (HCN),  

sulphur dioxide (SO2)  

ammonia (NH3)  

Solid and liquid particles (Aerosols) 

 

 

 

* Filtres for Clean-air blower units are marked acc. to  EN 12 941 

 

 

 

   The grid needn´t list all available types of filters, contact your supplier for complete current offer. 

6.2.  Batteries  

NOTE ! Batteries are delivered  discharged. All batteries must be charged before they are used for the first time. 

The battery can be charged separately or on the blower unit. 

The charger must not be used for any other purpose than that for which it was manufactured.  Do not charge the 

battery  in  a  potentially  explosive  atmosphere.  The  battery  charger  is  intended  for  indoor  use.    It  must  be 

protected against damp. The charger controls the charging automatically.  After the battery has been charged, 

the charger switches to the trickle charging regime and keeps the battery fully charged.  The charging time is 10 

to 14 hours depending on the type of battery. 

6.2.1.  Battery charging 

1.  Check that the voltage of the electrical power supply is correct. 

2.  Plug the charger into the socket.  

3.  Connect  the  battery  to  the  charger.    The  socket  of  the  battery  is  positioned  on  the  back  side.    The 

charging regime is signalised by a red LED diode light.   

4.  After charging has been completed, the trickle charging regime is activated:    

- charger for CA BASIC: red LED diode goes out, the green LED diode comes on at the moment of 

trickle charging  

5.  Disconnect the charger  from the power supply.   

 

Do not leave the charger in the power supply if not in use ! 

6.2.2.  Battery changing 

CA BASIC 2000  

 

 

 

 

…...................  see picture supplement no.3

pict. 3A : Removing the battery: Take the blower unit in both hands facing the rear side of battery towards you. 

Open the battery latch with your thumb. The latch is positioned in the middle of the battery. Push the 

battery off the unit using your thumbs. 

pict. 3B : Fitting the battery: Hold the blower unit in the same position as before. Put the battery on the rail and 

push it back onto the unit until the latch locks  it in the correct positon.  

Содержание BASIC 2000

Страница 1: ...motorized respiratory systems Clean air BASIC 2000 Clean air Basic 2000 Flow Control Clean air Basic 2000 Dual Flow Instructions for Use This instruction leaflet must be read and followed...

Страница 2: ...nto a headpiece a hood or mask The supply of filtrated air creates positive pressure inside the headpiece which prevents the external contaminated air from entering the user s breathing zone The suppl...

Страница 3: ...n t get caught on something in the surrounding Respiratory system CA BASIC 2000 is restricted for protection against solid and liquid particles only Do not use it against toxic gases and vapours It is...

Страница 4: ...t Green LED diodes shows the actual airflow level The unit ensures a constant supply of air The microprocessor inside the unit automatically regulates the motor speed to compensate the filter clogging...

Страница 5: ...liquids or abrasive cleaners The outer surface of the blower unit can be cleaned with a soft cloth wet slightly in a mild solution of clean water and mild detergent Dry it properly afterwards Ensure t...

Страница 6: ...charge the battery in a potentially explosive atmosphere The battery charger is intended for indoor use It must be protected against damp The charger controls the charging automatically After the bat...

Страница 7: ...anty The claiming procedure will be successful only on condition that there were no changes made on the blower unit incl the battery and charger If the damage is caused by not changing a clogged filte...

Страница 8: ...y r e t t a b h M i N s r u o h 4 1 o t 0 1 e l c y c g n i g r a h c e n O Belt size 80 to 100 cm Recommended temperature range 10 to 40 C Recommended humidity range 20 to 80 Rh 3 H T 2 H T 1 4 9 2...

Страница 9: ...AIR BASIC 2000 DF blower incl battery and airfow indicatior 820000P CLEAN AIR BASIC 2000 FC complete set blower incl battery air hose belt charger EN 820000PU CLEAN AIR BASIC 2000 FC complete set blow...

Страница 10: ...11 Picture supplements Changing the filter 1B 1C 1D 1A CA BASIC 2000...

Страница 11: ...12 Changing the battery CA BASIC 2000 3A 3B...

Отзывы: