4.  Before use     

   

   

   

   

   

   

   

     

4.1.  Inspection before use

Each time before starting work check that :  

  all  components  are  in  good  condition  with  no  visible  damage  (like  holes,  tears  etc.)  Replace  any 

damaged or worn parts.  Carefully examine the air hose, seals and the facepiece. 

  there is a good connection between the air hose and the headpiece as well as the blower unit 

  there is sufficient air flow.  (see chapt. 4.2.) 

  the air is supplied through the whole respiratory system from the blower to the hood. 

Charge the battery before the first use, see chapt. 6.2. 

4.2.  Air Flow Test

CA BASIC 2000 DUAL FLOW

1.  Disconnect the air hose from the hood. 

2.  Insert the indicator (the light  ball) into the air hose connector and keep the hose in vertical position at 

about the eye level. 

3. 

Switch the power unit on. The airflow is sufficient if at least half of the indicator can be seen.  If the 

indicator  sinks  deeper  into  the  hose  connector,  the  airflow  is  less  then  120  l/min.    In  that  case  it  is 

necessary  to  charge  the  battery  or  change  the  filter.  If  the  problem  still  persists,  see  chapter  7  for 

additional suggestions.

  

CA BASIC 2000 FLOW CONTROL

1.  Disconnect the air hose from the hood. 

2.  Cover the disconnected end of the air hose with your hand. The blower starts to run faster after about 20 

seconds, the audible alarm activates and the LED diodes on the control panel start blinking. 

3.  Release the hand . The blower speed should decrease.  

 

If the blower speed does not change, it is necessary to check the unit as described in chapter 7. 

5.  Maintanence / Cleaning     

   

   

   

   

   

     

It is recommended to clean the respiratory system after each use. Also inspect all parts and replace any which 

are damaged or worn. 

  Always clean the respiratory unit in a ventilated room or outside.  Be aware of harmful dust settled on 

any parts of the unit.  

  Never use flammable cleaning liquids or abrasive cleaners ! 

  The outer surface of the blower unit can be cleaned with a soft cloth wet slightly in a mild solution of 

clean water and mild detergent. Dry it properly afterwards. 

  Ensure that no water or detergents enter into the blower unit ! 

  The air hose itself, detached from the blower unit and the headpiece, can be rinsed in clean water.  

6.  Spare parts / Replacing spare parts   

   

   

   

   

     

6.1.  Filter

CA BASIC 2000  

The respiratory power unit is equipped with a high efficiency particle filter of class PSL. 

The filter must be regularly checked (see Air Flow Test - chapter 4.2.) and replaced.    
Make sure that the new filter is within its expiry date, unused and not evidently damaged. 

 

From the hygienic point of view  the maximum working time of a filter is 180 hours and should not be exceeded.  

It is prohibited to clean the filter by any procedure! 

 

 

 

 

 

 

 

  

The  particle  filter  can  be  used  with  a  Pre-filter  or  with  an  Odour  filter  which  removes  the  unwanted  smell  of 

harmless gases.   
CHANGING THE FILTER OF CA BASIC 2000   

 …...................  see picture supplement no.1 

pict. 1A : Removing the filter cover: Face the silver filter cover towards you. Put your index fingers and middle 

fingers into the gaps  between the body of the unit and the filter cover  on both sides. 

pict.  1B  :  Rest  your  thumbs  on  the  top  of  the  silver  filter  cover.    Then  pull  your  fingers  placed  in  the  gaps 

outwards  lifting  the  filter  cover  off  the  unit.    ATTENTION!  It  is  strictly  forbidden  to  use  any  tools  to 

uncover the filter. 

pict. 1C : To remove the filter, take it out while rotating it. Clean the unit from dust. 

pict. 1D : Inserting a new filter: If you are using a prefilter or an odourfilter, fix it around the new filter as tight as 

possible and stick the ends together using the sticky tape which is prepared on the prefilter/odourfilter. 

Put the filter back into position using the same rotating motion and gently push until it fits well on the 

body of the unit . Cover the filter with the silver filter cover. Pay special attention to snap the cover 

properly (on both sides).

Содержание BASIC 2000

Страница 1: ...motorized respiratory systems Clean air BASIC 2000 Clean air Basic 2000 Flow Control Clean air Basic 2000 Dual Flow Instructions for Use This instruction leaflet must be read and followed...

Страница 2: ...nto a headpiece a hood or mask The supply of filtrated air creates positive pressure inside the headpiece which prevents the external contaminated air from entering the user s breathing zone The suppl...

Страница 3: ...n t get caught on something in the surrounding Respiratory system CA BASIC 2000 is restricted for protection against solid and liquid particles only Do not use it against toxic gases and vapours It is...

Страница 4: ...t Green LED diodes shows the actual airflow level The unit ensures a constant supply of air The microprocessor inside the unit automatically regulates the motor speed to compensate the filter clogging...

Страница 5: ...liquids or abrasive cleaners The outer surface of the blower unit can be cleaned with a soft cloth wet slightly in a mild solution of clean water and mild detergent Dry it properly afterwards Ensure t...

Страница 6: ...charge the battery in a potentially explosive atmosphere The battery charger is intended for indoor use It must be protected against damp The charger controls the charging automatically After the bat...

Страница 7: ...anty The claiming procedure will be successful only on condition that there were no changes made on the blower unit incl the battery and charger If the damage is caused by not changing a clogged filte...

Страница 8: ...y r e t t a b h M i N s r u o h 4 1 o t 0 1 e l c y c g n i g r a h c e n O Belt size 80 to 100 cm Recommended temperature range 10 to 40 C Recommended humidity range 20 to 80 Rh 3 H T 2 H T 1 4 9 2...

Страница 9: ...AIR BASIC 2000 DF blower incl battery and airfow indicatior 820000P CLEAN AIR BASIC 2000 FC complete set blower incl battery air hose belt charger EN 820000PU CLEAN AIR BASIC 2000 FC complete set blow...

Страница 10: ...11 Picture supplements Changing the filter 1B 1C 1D 1A CA BASIC 2000...

Страница 11: ...12 Changing the battery CA BASIC 2000 3A 3B...

Отзывы: