5900e Greensand Filter Installation & Startup Guide
Page 19
www.cleanwaterstore.com
Rev 082216
How To Remove Media From Control Head
Sometimes, when doing the Initial Backwash, the media gets lifted up into the control head. You can tell
this happened because you will have little or no flow, either going out to drain while in the backwash
positon, or when in the service positon.
To remove media from a control head, do the following:
1) Put the Inlet Bypass in the Closed position.
2) From the Service Mode, initiate a manual regeneration, by pressing and holding the regen button
(button on far left).
3) The valve will advance to the BW (backwash) position, and start counting down. Press the Regen
button again, and wait for the valve to advance and stop at the Rapid Rinse (RR) position.
4) With the valve in the RR position, open and close the Inlet Bypass valve several times. After the third
or fourth time, leave it in the open position and check the drain line- do you have a good solid flow?
90% of the time, the answer is yes, but sometimes, even after opening and closing the valve many times,
you still don’t have good flow… But, in either case (good or no flow), continue…
5) With the Inlet Valve OFF, Advance the valve back to Service position again, and again press and hold
the Regen button, we are putting the valve back to the Backwash position.
6) Open the Inlet valve just enough so you can hear the water passing thru the valve- you should notice
a corresponding slow flow out of the drain line. After a minute, if there are no air bubbles present, open
the valve about another quarter inch- again, you should see a corresponding increase in the flow… And
you will continue until the valve is full open.
IMPORTANT:
Any time that you are in the Backwash or Rapid Rinse position, you may need to unplug the power- this
will hold the valve in its current position, so it doesn’t ‘time out’ and go to the next position. When you
plug the valve back in, after a minute it will return to where it was when you unplugged it (i.e. 2:32
remaining in BW). Understand, it is not possible to jam media into the head while in Rapid Rinse, or
Service, just in the Backwash, when the flow direction is reversed.
What you are trying to accomplish, after you have pushed the media back in to the tank in the Rapid
Rinse position, is to get the Inlet valve all the way open in the Backwash position, without it jamming
media back in the head, and this is the part where you have to go slow, open up the Inlet valve a little
bit at a time and let it run for a few minutes- this is why you may have to unplug it- and then, once you
have done that, finally, do one more backwash, starting with the Inlet valve open, just as it will be when
it does it automatically at night. Once it does that successfully, you are done.