![Clean Water Systems 7500 Series Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/clean-water-systems/7500-series/7500-series_installation-and-start-up-manual_2620082012.webp)
7500 Carbon Filter Installation & Startup Guide
Page 12
www.cleanwaterstore.com
Rev 083016
7.
3 – 10
m
This menu item is for the number of minutes for the Fast (or Rapid) Rinse. The
default is 10 minutes. Press the menu/confirm button, the 10 will flash; adjust it down
to 06 with the Scroll Down button, and press the Menu/ Confirm button. Now the valve
is programmed to Rapid Rinse for six minutes. Press the scroll down button, and you
are back at the first menu item, b – 01. Press the Menu/Confirm button, and the Green
Wrench Icon goes away, the Dynamic Display Stripe returns, and you are done
programming your valve.
When the motor is turning -00- is displayed…
This valve can be used with Chemsorb (Sediment media), Calcite (Acid Neutralizer media),
Carbon (Carbon media) and different types of Iron Removal media (Pro-Ox, Mang-Ox, Katalox
Lite and Greensand with chlorine feed).
Initial Backwash:
1
After programming, the system must be run through an initial backwash.
2
Close inlet valve B and outlet valve C, and open the bypass valve A. From the initial valve
menu, press the Manual/Return button to enter into the backwashing. When the backwash
icon is displayed, slowly open the inlet valve B to a quarter position to make the water flow
into the resin tank; you should be able to hear the sound of air escaping from the drain
pipeline. After all the air is out of the pipeline, open inlet valve B and clean the foreign
materials in the tank until the water is clean.
3
Verify that the backwash flow corresponds with the size of your system below. You can
easily run the drain hose to a bucket and using a watch verify the flow rate in gallons per
minute. An adequate backwash is critical to properly clean the Carbon media and prevent it
from fouling or channeling.
0.75 CF
5 GPM
1.0 CF
5 GPM
1.5 CF
5 GPM
2.0 CF
7 GPM
2.5 CF
7 GPM
3.0 CF
10 GPM